预测剪应力暴露诱导红细胞亚溶血损伤的水平和持续时间。

IF 1 4区 医学 Q4 BIOPHYSICS Biorheology Pub Date : 2017-03-29 DOI:10.3233/BIR-16120
Michael J. Simmonds, H. Meiselman
{"title":"预测剪应力暴露诱导红细胞亚溶血损伤的水平和持续时间。","authors":"Michael J. Simmonds, H. Meiselman","doi":"10.3233/BIR-16120","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nCurrent generation mechanical circulatory assist devices are designed to minimize high shears to blood for prolonged durations to avoid hemolysis. However, red blood cells (RBC) demonstrate impaired capacity to deform when exposed to shear stress (SS) well below the \"hemolytic threshold\".\n\n\nOBJECTIVE\nWe endeavored to identify how changes in the magnitude and duration of SS exposure alter RBC deformability and subsequently develop a model to predict erythrocyte subhemolytic damage.\n\n\nMETHODS\nRBC suspensions were exposed to discrete magnitudes of SS (1-64 Pa) for specific durations (1-64 s), immediately prior to RBC deformability being measured. Analyses included exploring the maximal RBC deformation (EImax) and SS required for half EImax (SS1/2). A surface-mesh was interpolated onto the raw data to predict impaired RBC deformability.\n\n\nRESULTS\nWhen SS was applied at <16Pa, limited changes were observed. When RBC were exposed to 32 Pa, mild impairments in EImax and SS1/2 occurred, although 64 Pa caused a dramatic impairment of RBC deformability. A clear relation between SS duration and magnitude was determined, which could predict impaired RBC deformability.\n\n\nCONCLUSION\nThe present results provide a model that may be used to predict whether RBC deformability is decreased following exposure to a given level and duration of SS, and may guide design of future generations of mechanical circulatory assist devices.","PeriodicalId":9167,"journal":{"name":"Biorheology","volume":"53 5-6 1","pages":"237-249"},"PeriodicalIF":1.0000,"publicationDate":"2017-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3233/BIR-16120","citationCount":"40","resultStr":"{\"title\":\"Prediction of the level and duration of shear stress exposure that induces subhemolytic damage to erythrocytes.\",\"authors\":\"Michael J. Simmonds, H. Meiselman\",\"doi\":\"10.3233/BIR-16120\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND\\nCurrent generation mechanical circulatory assist devices are designed to minimize high shears to blood for prolonged durations to avoid hemolysis. However, red blood cells (RBC) demonstrate impaired capacity to deform when exposed to shear stress (SS) well below the \\\"hemolytic threshold\\\".\\n\\n\\nOBJECTIVE\\nWe endeavored to identify how changes in the magnitude and duration of SS exposure alter RBC deformability and subsequently develop a model to predict erythrocyte subhemolytic damage.\\n\\n\\nMETHODS\\nRBC suspensions were exposed to discrete magnitudes of SS (1-64 Pa) for specific durations (1-64 s), immediately prior to RBC deformability being measured. Analyses included exploring the maximal RBC deformation (EImax) and SS required for half EImax (SS1/2). A surface-mesh was interpolated onto the raw data to predict impaired RBC deformability.\\n\\n\\nRESULTS\\nWhen SS was applied at <16Pa, limited changes were observed. When RBC were exposed to 32 Pa, mild impairments in EImax and SS1/2 occurred, although 64 Pa caused a dramatic impairment of RBC deformability. A clear relation between SS duration and magnitude was determined, which could predict impaired RBC deformability.\\n\\n\\nCONCLUSION\\nThe present results provide a model that may be used to predict whether RBC deformability is decreased following exposure to a given level and duration of SS, and may guide design of future generations of mechanical circulatory assist devices.\",\"PeriodicalId\":9167,\"journal\":{\"name\":\"Biorheology\",\"volume\":\"53 5-6 1\",\"pages\":\"237-249\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2017-03-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3233/BIR-16120\",\"citationCount\":\"40\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biorheology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3233/BIR-16120\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biorheology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/BIR-16120","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 40

摘要

背景:电流产生机械循环辅助装置的设计是为了尽量减少长时间对血液的高剪切,以避免溶血。然而,当暴露在远低于“溶血阈值”的剪切应力(SS)下时,红细胞(RBC)显示出变形能力受损。目的:我们试图确定SS暴露的强度和持续时间的变化如何改变红细胞变形能力,并随后建立一个预测红细胞亚溶血损伤的模型。方法在测量RBC变形能力之前,将srbc悬浮液暴露于离散强度的SS (1-64 Pa)中特定时间(1-64 s)。分析包括探索最大RBC变形(EImax)和一半EImax所需的SS (SS1/2)。将表面网格插值到原始数据上以预测RBC变形能力受损。结果SS作用于<16Pa时,变化有限。当RBC暴露于32 Pa时,EImax和SS1/2发生轻度损伤,尽管64 Pa引起RBC变形能力的严重损伤。SS持续时间与强度之间有明显的关系,可以预测红细胞变形能力受损。结论本研究结果提供了一个模型,可用于预测暴露于给定水平和持续时间的SS后红细胞变形能力是否降低,并可指导未来几代机械循环辅助装置的设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Prediction of the level and duration of shear stress exposure that induces subhemolytic damage to erythrocytes.
BACKGROUND Current generation mechanical circulatory assist devices are designed to minimize high shears to blood for prolonged durations to avoid hemolysis. However, red blood cells (RBC) demonstrate impaired capacity to deform when exposed to shear stress (SS) well below the "hemolytic threshold". OBJECTIVE We endeavored to identify how changes in the magnitude and duration of SS exposure alter RBC deformability and subsequently develop a model to predict erythrocyte subhemolytic damage. METHODS RBC suspensions were exposed to discrete magnitudes of SS (1-64 Pa) for specific durations (1-64 s), immediately prior to RBC deformability being measured. Analyses included exploring the maximal RBC deformation (EImax) and SS required for half EImax (SS1/2). A surface-mesh was interpolated onto the raw data to predict impaired RBC deformability. RESULTS When SS was applied at <16Pa, limited changes were observed. When RBC were exposed to 32 Pa, mild impairments in EImax and SS1/2 occurred, although 64 Pa caused a dramatic impairment of RBC deformability. A clear relation between SS duration and magnitude was determined, which could predict impaired RBC deformability. CONCLUSION The present results provide a model that may be used to predict whether RBC deformability is decreased following exposure to a given level and duration of SS, and may guide design of future generations of mechanical circulatory assist devices.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biorheology
Biorheology 医学-工程:生物医学
CiteScore
2.00
自引率
0.00%
发文量
5
审稿时长
>12 weeks
期刊介绍: Biorheology is an international interdisciplinary journal that publishes research on the deformation and flow properties of biological systems or materials. It is the aim of the editors and publishers of Biorheology to bring together contributions from those working in various fields of biorheological research from all over the world. A diverse editorial board with broad international representation provides guidance and expertise in wide-ranging applications of rheological methods to biological systems and materials. The scope of papers solicited by Biorheology extends to systems at different levels of organization that have never been studied before, or, if studied previously, have either never been analyzed in terms of their rheological properties or have not been studied from the point of view of the rheological matching between their structural and functional properties. This biorheological approach applies in particular to molecular studies where changes of physical properties and conformation are investigated without reference to how the process actually takes place, how the forces generated are matched to the properties of the structures and environment concerned, proper time scales, or what structures or strength of structures are required.
期刊最新文献
The impact of measurement techniques and common effectors on red blood cell aggregation. Blood rheology and systemic oxidative status in patients with acromegaly. Abstracts of the 2nd Annual Conference of the Austrian Society for Rheology. Abstracts of the 2nd Annual Conference of the Austrian Society for Rheology. HIIT serves as an efficient training strategy for basketball players by improving blood fluidity and decreasing oxidative stress
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1