{"title":"漫反射便携式近红外光谱法测定尿素肥料中双缩脲含量","authors":"Jing Liu, Sha Yu, Shupeng Hu, Ziyang Ling, Jiguang Gao, Binmei Liu, Lixiang Yu, Yang Yang, Ye Yang, Qi Wang, Xiaoyu Ni, Liping Zhao, Yuejin Wu","doi":"10.1177/09670335221136546","DOIUrl":null,"url":null,"abstract":"Simple, rapid, and reliable determination of the biuret content in urea fertilizer is very important for the development of fertilizer industry. A near infrared diffuse reflectance measurement system with a portable spectrometer was developed, in which the reference and dark background spectrum could also be recorded automatically in addition to the absorbance data. The key performances of the proposed NIR system have been tested on urea fertilizer. Numerical experiments showed that the coefficient of determination (R2) of the external validation set was 0.97, with a root mean square error (RMSE) of 0.04%. The ratios of the performance deviation (RPD) value in the calibration and validation sets were 12 and 3.5, respectively. It can be concluded that this NIR system for the determination of biuret content in urea fertilizer may potentially be used as an alternative method to traditional wet chemical methods due to its simplicity, sensitivity, and portability.","PeriodicalId":16551,"journal":{"name":"Journal of Near Infrared Spectroscopy","volume":"31 1","pages":"33 - 40"},"PeriodicalIF":1.6000,"publicationDate":"2022-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A diffuse reflectance portable near infrared spectroscopy system for the determination of biuret content in urea fertilizer\",\"authors\":\"Jing Liu, Sha Yu, Shupeng Hu, Ziyang Ling, Jiguang Gao, Binmei Liu, Lixiang Yu, Yang Yang, Ye Yang, Qi Wang, Xiaoyu Ni, Liping Zhao, Yuejin Wu\",\"doi\":\"10.1177/09670335221136546\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Simple, rapid, and reliable determination of the biuret content in urea fertilizer is very important for the development of fertilizer industry. A near infrared diffuse reflectance measurement system with a portable spectrometer was developed, in which the reference and dark background spectrum could also be recorded automatically in addition to the absorbance data. The key performances of the proposed NIR system have been tested on urea fertilizer. Numerical experiments showed that the coefficient of determination (R2) of the external validation set was 0.97, with a root mean square error (RMSE) of 0.04%. The ratios of the performance deviation (RPD) value in the calibration and validation sets were 12 and 3.5, respectively. It can be concluded that this NIR system for the determination of biuret content in urea fertilizer may potentially be used as an alternative method to traditional wet chemical methods due to its simplicity, sensitivity, and portability.\",\"PeriodicalId\":16551,\"journal\":{\"name\":\"Journal of Near Infrared Spectroscopy\",\"volume\":\"31 1\",\"pages\":\"33 - 40\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2022-11-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Near Infrared Spectroscopy\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1177/09670335221136546\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Near Infrared Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/09670335221136546","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, APPLIED","Score":null,"Total":0}
A diffuse reflectance portable near infrared spectroscopy system for the determination of biuret content in urea fertilizer
Simple, rapid, and reliable determination of the biuret content in urea fertilizer is very important for the development of fertilizer industry. A near infrared diffuse reflectance measurement system with a portable spectrometer was developed, in which the reference and dark background spectrum could also be recorded automatically in addition to the absorbance data. The key performances of the proposed NIR system have been tested on urea fertilizer. Numerical experiments showed that the coefficient of determination (R2) of the external validation set was 0.97, with a root mean square error (RMSE) of 0.04%. The ratios of the performance deviation (RPD) value in the calibration and validation sets were 12 and 3.5, respectively. It can be concluded that this NIR system for the determination of biuret content in urea fertilizer may potentially be used as an alternative method to traditional wet chemical methods due to its simplicity, sensitivity, and portability.
期刊介绍:
JNIRS — Journal of Near Infrared Spectroscopy is a peer reviewed journal, publishing original research papers, short communications, review articles and letters concerned with near infrared spectroscopy and technology, its application, new instrumentation and the use of chemometric and data handling techniques within NIR.