气动肌肉致动器的特性及其在具有新型铰链设计的肘关节外骨骼上的实现

IF 6.5 Q1 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Sensors and Actuators Reports Pub Date : 2022-11-01 DOI:10.1016/j.snr.2022.100109
Antonio Dylan Do Rosario Carvalho, Navin Karanth P, Vijay Desai
{"title":"气动肌肉致动器的特性及其在具有新型铰链设计的肘关节外骨骼上的实现","authors":"Antonio Dylan Do Rosario Carvalho,&nbsp;Navin Karanth P,&nbsp;Vijay Desai","doi":"10.1016/j.snr.2022.100109","DOIUrl":null,"url":null,"abstract":"<div><p>The exoskeleton plays an essential role in the field of physical rehabilitation. Several actuators are used for the exoskeleton application, but the pneumatic muscle actuator has proved to be the best due to its high power to weight ratio, compliance, and safe operation. The objective of this paper involves the fabrication and experimental characterization of a pneumatic muscle actuator to actuate an exoskeleton for the elbow joint. This paper presents the development and testing of twelve pneumatic muscles of varying materials and sizes, to find the best combination to suit the intended application. The characterization process involved several tests, which related force, deflection, and pressure at various loading conditions. A modular test rig was developed to conduct all the tests with minor adjustments to the test setup. The study also involved designing and developing an elbow exoskeleton to test the pneumatic muscle in the real-world scenario. The exoskeleton is designed with a novel hinge to compensate for the antagonistic nature of the pneumatic muscle actuator. The tests showed the muscles with higher tensile modules bladders having a lower hysteresis and better load handling capability, but these suffered from lower contraction and force characteristics. The styrene-based muscle with a 12mm bladder (S12LB) showed the best force and deflection characteristics at various pressures and loading conditions. The styrene bladder has a modulus closer to the skeletal muscle, therefore demonstrating higher compliance and making it a preferred choice for the exoskeleton application</p></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":null,"pages":null},"PeriodicalIF":6.5000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666053922000364/pdfft?md5=7533054427beb39d3b9f8ce69ab815df&pid=1-s2.0-S2666053922000364-main.pdf","citationCount":"5","resultStr":"{\"title\":\"Characterization of pneumatic muscle actuators and their implementation on an elbow exoskeleton with a novel hinge design\",\"authors\":\"Antonio Dylan Do Rosario Carvalho,&nbsp;Navin Karanth P,&nbsp;Vijay Desai\",\"doi\":\"10.1016/j.snr.2022.100109\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The exoskeleton plays an essential role in the field of physical rehabilitation. Several actuators are used for the exoskeleton application, but the pneumatic muscle actuator has proved to be the best due to its high power to weight ratio, compliance, and safe operation. The objective of this paper involves the fabrication and experimental characterization of a pneumatic muscle actuator to actuate an exoskeleton for the elbow joint. This paper presents the development and testing of twelve pneumatic muscles of varying materials and sizes, to find the best combination to suit the intended application. The characterization process involved several tests, which related force, deflection, and pressure at various loading conditions. A modular test rig was developed to conduct all the tests with minor adjustments to the test setup. The study also involved designing and developing an elbow exoskeleton to test the pneumatic muscle in the real-world scenario. The exoskeleton is designed with a novel hinge to compensate for the antagonistic nature of the pneumatic muscle actuator. The tests showed the muscles with higher tensile modules bladders having a lower hysteresis and better load handling capability, but these suffered from lower contraction and force characteristics. The styrene-based muscle with a 12mm bladder (S12LB) showed the best force and deflection characteristics at various pressures and loading conditions. The styrene bladder has a modulus closer to the skeletal muscle, therefore demonstrating higher compliance and making it a preferred choice for the exoskeleton application</p></div>\",\"PeriodicalId\":426,\"journal\":{\"name\":\"Sensors and Actuators Reports\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":6.5000,\"publicationDate\":\"2022-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666053922000364/pdfft?md5=7533054427beb39d3b9f8ce69ab815df&pid=1-s2.0-S2666053922000364-main.pdf\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666053922000364\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053922000364","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 5

摘要

外骨骼在物理康复领域起着重要的作用。外骨骼应用中使用了几种致动器,但气动肌肉致动器已被证明是最好的,因为它具有高功率重量比,顺应性和安全操作。本文的目的涉及气动肌肉致动器的制造和实验表征,以驱动肘关节外骨骼。本文介绍了12种不同材料和尺寸的气动肌肉的开发和测试,以找到适合预期应用的最佳组合。表征过程包括几个测试,这些测试与各种加载条件下的力、挠度和压力有关。开发了一个模块化测试平台,通过对测试设置进行微小调整来进行所有测试。该研究还包括设计和开发肘部外骨骼,以在现实场景中测试气动肌肉。外骨骼设计了一个新颖的铰链,以补偿气动肌肉执行器的拮抗性质。试验表明,具有较高拉伸模量的肌肉具有较低的迟滞和较好的负载处理能力,但这些肌肉的收缩和力特性较低。在各种压力和载荷条件下,具有12mm膀胱(S12LB)的苯乙烯基肌肉表现出最佳的受力和挠度特性。苯乙烯气囊的模量更接近骨骼肌,因此显示出更高的顺应性,使其成为外骨骼应用的首选
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Characterization of pneumatic muscle actuators and their implementation on an elbow exoskeleton with a novel hinge design

The exoskeleton plays an essential role in the field of physical rehabilitation. Several actuators are used for the exoskeleton application, but the pneumatic muscle actuator has proved to be the best due to its high power to weight ratio, compliance, and safe operation. The objective of this paper involves the fabrication and experimental characterization of a pneumatic muscle actuator to actuate an exoskeleton for the elbow joint. This paper presents the development and testing of twelve pneumatic muscles of varying materials and sizes, to find the best combination to suit the intended application. The characterization process involved several tests, which related force, deflection, and pressure at various loading conditions. A modular test rig was developed to conduct all the tests with minor adjustments to the test setup. The study also involved designing and developing an elbow exoskeleton to test the pneumatic muscle in the real-world scenario. The exoskeleton is designed with a novel hinge to compensate for the antagonistic nature of the pneumatic muscle actuator. The tests showed the muscles with higher tensile modules bladders having a lower hysteresis and better load handling capability, but these suffered from lower contraction and force characteristics. The styrene-based muscle with a 12mm bladder (S12LB) showed the best force and deflection characteristics at various pressures and loading conditions. The styrene bladder has a modulus closer to the skeletal muscle, therefore demonstrating higher compliance and making it a preferred choice for the exoskeleton application

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
9.60
自引率
0.00%
发文量
60
审稿时长
49 days
期刊介绍: Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications. For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.
期刊最新文献
Design and optimization of a Cr(VI)-Selective Electrode based on a polymeric ß-cyclodextrin membrane modified with sulfur donor groups Emerging detection of carbon-based gases with multiple bonds by activating MoO bonding in Na, Sb-codoped NiMoO4 Focused ion beam fabrication of high-resolution electrochemical-electroluminescence coupling bipolar nanoelectrode array sensors Ultra-fast detection of pathogens and protein biomarkers using a low-cost silicon plasmonic biosensing platform Enhanced Uric Acid Detection Using Functionalized Multi-walled Carbon Nanotube/AgNi Nanocomposites: A Comparative Study on Screen-printed Carbon Electrode (SPCE) and Fabric-based Biosensors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1