R. Anay, L. Assi, V. Soltangharaei, A. Abdulshaheed, H. Gleich, P. Ziehl
{"title":"形状记忆合金杆双三通法兰连接的研制","authors":"R. Anay, L. Assi, V. Soltangharaei, A. Abdulshaheed, H. Gleich, P. Ziehl","doi":"10.15554/pcij65.6-03","DOIUrl":null,"url":null,"abstract":"This study investigated the out-of-plane shear performance of a newly developed shape memory alloy (SMA) connector and a commonly used shear/alignment connector. The innovation lies in developing a durable and easily installed and maintained flange-to-flange connector between precast concrete double-tee members. The proposed connector consists of a superelastic SMA curved bolt inserted into a duct that is then cast into the precast concrete member. Two types of sealant materials were used: polyurethane elastomeric sealant and nonshrink cementitious grout. The shear/alignment and SMA connectors were tested under monotonic vertical shear. The tests were conducted on 4 ft × 4 ft × 4 in. (1.2 m × 1.2 m × 100 mm) slab specimens. The resulting capacities and associated damage were summarized. Higher stiffness and lower ductility were observed for the SMA connector with nonshrink grout compared with the shear/alignment connector with polyurethane elastomeric sealant. The average stiffnesses of the SMA and shear/alignment connector specimens were 116,681 lb/in. (20,434 kN/m) and 31,300 lb/in. (5481 kN/m), respectively. The ductility of the SMA connector was improved when using polyurethane elastomeric sealant; however, more tests should be done to confirm this behavior. The SMA rod was reused in several tests through reheating of the SMA element. The shear/alignment connector cannot be reused.","PeriodicalId":54637,"journal":{"name":"PCI Journal","volume":"65 1","pages":"81-96"},"PeriodicalIF":0.9000,"publicationDate":"2020-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Development of a double-tee flange connection using shape memory alloy rods\",\"authors\":\"R. Anay, L. Assi, V. Soltangharaei, A. Abdulshaheed, H. Gleich, P. Ziehl\",\"doi\":\"10.15554/pcij65.6-03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study investigated the out-of-plane shear performance of a newly developed shape memory alloy (SMA) connector and a commonly used shear/alignment connector. The innovation lies in developing a durable and easily installed and maintained flange-to-flange connector between precast concrete double-tee members. The proposed connector consists of a superelastic SMA curved bolt inserted into a duct that is then cast into the precast concrete member. Two types of sealant materials were used: polyurethane elastomeric sealant and nonshrink cementitious grout. The shear/alignment and SMA connectors were tested under monotonic vertical shear. The tests were conducted on 4 ft × 4 ft × 4 in. (1.2 m × 1.2 m × 100 mm) slab specimens. The resulting capacities and associated damage were summarized. Higher stiffness and lower ductility were observed for the SMA connector with nonshrink grout compared with the shear/alignment connector with polyurethane elastomeric sealant. The average stiffnesses of the SMA and shear/alignment connector specimens were 116,681 lb/in. (20,434 kN/m) and 31,300 lb/in. (5481 kN/m), respectively. The ductility of the SMA connector was improved when using polyurethane elastomeric sealant; however, more tests should be done to confirm this behavior. The SMA rod was reused in several tests through reheating of the SMA element. The shear/alignment connector cannot be reused.\",\"PeriodicalId\":54637,\"journal\":{\"name\":\"PCI Journal\",\"volume\":\"65 1\",\"pages\":\"81-96\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2020-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PCI Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.15554/pcij65.6-03\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PCI Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.15554/pcij65.6-03","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 3
摘要
研究了一种新开发的形状记忆合金(SMA)连接器和一种常用的剪切/对准连接器的面外剪切性能。创新在于在预制混凝土双三通构件之间开发一种耐用且易于安装和维护的法兰对法兰连接器。所提出的连接器由插入管道的超弹性SMA弯曲螺栓组成,然后将其浇铸到预制混凝土构件中。采用了两种密封材料:聚氨酯弹性体密封胶和非收缩胶凝灌浆。剪切/对准和SMA连接器在单调垂直剪切下进行了测试。试验尺寸为4英尺× 4英尺× 4英寸。(1.2 m × 1.2 m × 100 mm)板试件。总结了由此产生的能力和相关的损害。与使用聚氨酯弹性体密封胶的剪切/对准连接器相比,使用非收缩灌浆的SMA连接器具有更高的刚度和更低的延性。SMA和剪切/校直接头试件的平均刚度为116,681 lb/in。(20,434 kN/m)和31,300 lb/in。(5481 kN/m)。使用聚氨酯弹性体密封胶可以提高SMA连接器的延展性;但是,需要做更多的测试来确认这种行为。通过对SMA元件的再加热,在多次试验中重复使用了SMA棒。剪切/对准连接器不能重复使用。
Development of a double-tee flange connection using shape memory alloy rods
This study investigated the out-of-plane shear performance of a newly developed shape memory alloy (SMA) connector and a commonly used shear/alignment connector. The innovation lies in developing a durable and easily installed and maintained flange-to-flange connector between precast concrete double-tee members. The proposed connector consists of a superelastic SMA curved bolt inserted into a duct that is then cast into the precast concrete member. Two types of sealant materials were used: polyurethane elastomeric sealant and nonshrink cementitious grout. The shear/alignment and SMA connectors were tested under monotonic vertical shear. The tests were conducted on 4 ft × 4 ft × 4 in. (1.2 m × 1.2 m × 100 mm) slab specimens. The resulting capacities and associated damage were summarized. Higher stiffness and lower ductility were observed for the SMA connector with nonshrink grout compared with the shear/alignment connector with polyurethane elastomeric sealant. The average stiffnesses of the SMA and shear/alignment connector specimens were 116,681 lb/in. (20,434 kN/m) and 31,300 lb/in. (5481 kN/m), respectively. The ductility of the SMA connector was improved when using polyurethane elastomeric sealant; however, more tests should be done to confirm this behavior. The SMA rod was reused in several tests through reheating of the SMA element. The shear/alignment connector cannot be reused.