R. K. Hapsari, Miswanto, R. Rulaningtyas, H. Suprajitno, H. Gan
{"title":"改进灰度Haralick纹理特征用于虹膜图像早期检测糖尿病和高胆固醇","authors":"R. K. Hapsari, Miswanto, R. Rulaningtyas, H. Suprajitno, H. Gan","doi":"10.1155/2022/5336373","DOIUrl":null,"url":null,"abstract":"Iris has specific advantages, which can record all organ conditions, body construction, and psychological disorders. Traces related to the intensity or deviation of organs caused by the disease are recorded systematically and patterned on the iris and its surroundings. The pattern that appears on the iris can be recognized by using image processing techniques. Based on the pattern in the iris image, this paper aims to provide an alternative noninvasive method for the early detection of DM and HC. In this paper, we perform detection based on iris images for two diseases, DM and HC simultaneously, by developing the invariant Haralick feature on quantized images with 256, 128, 64, 32, and 16 gray levels. The feature extraction process does early detection based on iris images. Researchers and scientists have introduced many methods, one of which is the feature extraction of the gray-level co-occurrence matrix (GLCM). Early detection based on the iris is done using the volumetric GLCM development, namely, 3D-GLCM. Based on 3D-GLCM, which is formed at a distance of d = 1 and in the direction of 0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315°, it is used to calculate Haralick features and develop Haralick features which are invariant to the number of quantization gray levels. The test results show that the invariant feature with a gray level of 256 has the best identification performance. In dataset I, the accuracy value is 97.92, precision is 96.88, and recall is 95.83, while in dataset II, the accuracy value is 95.83, precision is 89.69, and recall is 91.67. The identification of DM and HC trained on invariant features showed higher accuracy than the original features.","PeriodicalId":47063,"journal":{"name":"International Journal of Biomedical Imaging","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2022-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Modified Gray-Level Haralick Texture Features for Early Detection of Diabetes Mellitus and High Cholesterol with Iris Image\",\"authors\":\"R. K. Hapsari, Miswanto, R. Rulaningtyas, H. Suprajitno, H. Gan\",\"doi\":\"10.1155/2022/5336373\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Iris has specific advantages, which can record all organ conditions, body construction, and psychological disorders. Traces related to the intensity or deviation of organs caused by the disease are recorded systematically and patterned on the iris and its surroundings. The pattern that appears on the iris can be recognized by using image processing techniques. Based on the pattern in the iris image, this paper aims to provide an alternative noninvasive method for the early detection of DM and HC. In this paper, we perform detection based on iris images for two diseases, DM and HC simultaneously, by developing the invariant Haralick feature on quantized images with 256, 128, 64, 32, and 16 gray levels. The feature extraction process does early detection based on iris images. Researchers and scientists have introduced many methods, one of which is the feature extraction of the gray-level co-occurrence matrix (GLCM). Early detection based on the iris is done using the volumetric GLCM development, namely, 3D-GLCM. Based on 3D-GLCM, which is formed at a distance of d = 1 and in the direction of 0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315°, it is used to calculate Haralick features and develop Haralick features which are invariant to the number of quantization gray levels. The test results show that the invariant feature with a gray level of 256 has the best identification performance. In dataset I, the accuracy value is 97.92, precision is 96.88, and recall is 95.83, while in dataset II, the accuracy value is 95.83, precision is 89.69, and recall is 91.67. The identification of DM and HC trained on invariant features showed higher accuracy than the original features.\",\"PeriodicalId\":47063,\"journal\":{\"name\":\"International Journal of Biomedical Imaging\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2022-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Biomedical Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2022/5336373\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Biomedical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2022/5336373","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Modified Gray-Level Haralick Texture Features for Early Detection of Diabetes Mellitus and High Cholesterol with Iris Image
Iris has specific advantages, which can record all organ conditions, body construction, and psychological disorders. Traces related to the intensity or deviation of organs caused by the disease are recorded systematically and patterned on the iris and its surroundings. The pattern that appears on the iris can be recognized by using image processing techniques. Based on the pattern in the iris image, this paper aims to provide an alternative noninvasive method for the early detection of DM and HC. In this paper, we perform detection based on iris images for two diseases, DM and HC simultaneously, by developing the invariant Haralick feature on quantized images with 256, 128, 64, 32, and 16 gray levels. The feature extraction process does early detection based on iris images. Researchers and scientists have introduced many methods, one of which is the feature extraction of the gray-level co-occurrence matrix (GLCM). Early detection based on the iris is done using the volumetric GLCM development, namely, 3D-GLCM. Based on 3D-GLCM, which is formed at a distance of d = 1 and in the direction of 0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315°, it is used to calculate Haralick features and develop Haralick features which are invariant to the number of quantization gray levels. The test results show that the invariant feature with a gray level of 256 has the best identification performance. In dataset I, the accuracy value is 97.92, precision is 96.88, and recall is 95.83, while in dataset II, the accuracy value is 95.83, precision is 89.69, and recall is 91.67. The identification of DM and HC trained on invariant features showed higher accuracy than the original features.
期刊介绍:
The International Journal of Biomedical Imaging is managed by a board of editors comprising internationally renowned active researchers. The journal is freely accessible online and also offered for purchase in print format. It employs a web-based review system to ensure swift turnaround times while maintaining high standards. In addition to regular issues, special issues are organized by guest editors. The subject areas covered include (but are not limited to):
Digital radiography and tomosynthesis
X-ray computed tomography (CT)
Magnetic resonance imaging (MRI)
Single photon emission computed tomography (SPECT)
Positron emission tomography (PET)
Ultrasound imaging
Diffuse optical tomography, coherence, fluorescence, bioluminescence tomography, impedance tomography
Neutron imaging for biomedical applications
Magnetic and optical spectroscopy, and optical biopsy
Optical, electron, scanning tunneling/atomic force microscopy
Small animal imaging
Functional, cellular, and molecular imaging
Imaging assays for screening and molecular analysis
Microarray image analysis and bioinformatics
Emerging biomedical imaging techniques
Imaging modality fusion
Biomedical imaging instrumentation
Biomedical image processing, pattern recognition, and analysis
Biomedical image visualization, compression, transmission, and storage
Imaging and modeling related to systems biology and systems biomedicine
Applied mathematics, applied physics, and chemistry related to biomedical imaging
Grid-enabling technology for biomedical imaging and informatics