腕管综合征可穿戴系统的研制

IF 1.5 Q2 MATERIALS SCIENCE, TEXTILES Research journal of textile and apparel Pub Date : 2022-07-21 DOI:10.1108/rjta-10-2021-0122
F. Iftikhar, Suleman Anis, Umar Bin Asad, S. Riaz, Muntaha Rafiq, Salman Naeem
{"title":"腕管综合征可穿戴系统的研制","authors":"F. Iftikhar, Suleman Anis, Umar Bin Asad, S. Riaz, Muntaha Rafiq, Salman Naeem","doi":"10.1108/rjta-10-2021-0122","DOIUrl":null,"url":null,"abstract":"\nPurpose\nCarpal tunnel syndrome (CTS) is a hand disease caused by the pressing of the median nerve present in the palmar side of the wrist. It causes severe pain in the wrist, triggering disturbance during sleep. Different products like splints, braces and gloves are available in the market to alleviate this disease but there was still a need to improve the wearability, comfort and cost of the product. This study was about designing a comfortable and cost-effective wearable system for mild-to-moderate CTS. Transcutaneous electrical nerve stimulation (TENS) therapy has been used to reduce the pain in the wrist.\n\n\nDesign/methodology/approach\nAfter simulation by using Proteus software (which allowed the researchers to draw and simulate electrical circuits using ISIS, ARES and PCB design tools virtually), the circuit with optimum frequency, i.e. 33 Hz was selected, and the circuit was developed on a printed circuit board (PCB). The developed circuit was integrated successfully into the half glove structure.\n\n\nFindings\nThe developed product had good thermophysiological comfort and hand properties as compared to the commercially available product of the same kind. In vivo testing (It involves the testing with living subjects like animals, plants or human beings) was performed which resulted in 85% confirmed viability of the product against CTS. A glove with an integrated circuit was developed successfully to accommodate various sizes without any sex specifications in a cost-effective way to mitigate the issue of CTS.\n\n\nResearch limitations/implications\nIndustrial workers, individuals frequently using their hands or those diagnosed with CTS may wish to use this product as therapy. The attention could not be paid to the aesthetic or visual appeal of the developed product.\n\n\nOriginality/value\nA very comfortable glove with integrated TENS electrodes was developed successfully to accommodate various sizes without any sex specifications in a cost-effective way to mitigate the issues of CTS.\n","PeriodicalId":21107,"journal":{"name":"Research journal of textile and apparel","volume":" ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2022-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of wearable system for carpal tunnel syndrome\",\"authors\":\"F. Iftikhar, Suleman Anis, Umar Bin Asad, S. Riaz, Muntaha Rafiq, Salman Naeem\",\"doi\":\"10.1108/rjta-10-2021-0122\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\nPurpose\\nCarpal tunnel syndrome (CTS) is a hand disease caused by the pressing of the median nerve present in the palmar side of the wrist. It causes severe pain in the wrist, triggering disturbance during sleep. Different products like splints, braces and gloves are available in the market to alleviate this disease but there was still a need to improve the wearability, comfort and cost of the product. This study was about designing a comfortable and cost-effective wearable system for mild-to-moderate CTS. Transcutaneous electrical nerve stimulation (TENS) therapy has been used to reduce the pain in the wrist.\\n\\n\\nDesign/methodology/approach\\nAfter simulation by using Proteus software (which allowed the researchers to draw and simulate electrical circuits using ISIS, ARES and PCB design tools virtually), the circuit with optimum frequency, i.e. 33 Hz was selected, and the circuit was developed on a printed circuit board (PCB). The developed circuit was integrated successfully into the half glove structure.\\n\\n\\nFindings\\nThe developed product had good thermophysiological comfort and hand properties as compared to the commercially available product of the same kind. In vivo testing (It involves the testing with living subjects like animals, plants or human beings) was performed which resulted in 85% confirmed viability of the product against CTS. A glove with an integrated circuit was developed successfully to accommodate various sizes without any sex specifications in a cost-effective way to mitigate the issue of CTS.\\n\\n\\nResearch limitations/implications\\nIndustrial workers, individuals frequently using their hands or those diagnosed with CTS may wish to use this product as therapy. The attention could not be paid to the aesthetic or visual appeal of the developed product.\\n\\n\\nOriginality/value\\nA very comfortable glove with integrated TENS electrodes was developed successfully to accommodate various sizes without any sex specifications in a cost-effective way to mitigate the issues of CTS.\\n\",\"PeriodicalId\":21107,\"journal\":{\"name\":\"Research journal of textile and apparel\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2022-07-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Research journal of textile and apparel\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1108/rjta-10-2021-0122\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, TEXTILES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research journal of textile and apparel","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/rjta-10-2021-0122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, TEXTILES","Score":null,"Total":0}
引用次数: 0

摘要

目的腕管综合征(CTS)是一种由腕部掌侧正中神经受压引起的手部疾病。它会导致手腕剧烈疼痛,引发睡眠障碍。市场上有不同的产品,如夹板、牙套和手套来缓解这种疾病,但仍然需要提高产品的可穿戴性、舒适性和成本。本研究旨在为轻中度CTS设计一种舒适且经济高效的可穿戴系统。经皮神经电刺激(TENS)疗法已被用于减轻手腕疼痛。设计/方法/方法通过Proteus软件(该软件允许研究人员使用ISIS, ARES和PCB设计工具虚拟地绘制和模拟电路)进行仿真,选择最佳频率(即33 Hz)的电路,并在印刷电路板(PCB)上开发电路。所开发的电路成功地集成到半手套结构中。结果:与市售同类产品相比,该产品具有良好的热生理舒适性和手部性能。在体内测试(包括动物,植物或人类等活体对象的测试)进行,结果确认85%的产品抗CTS的生存能力。成功开发了一种集成电路手套,以经济有效的方式适应各种尺寸,没有任何性别规格,以减轻CTS问题。研究局限性/意义产业工人,经常使用他们的手或被诊断为CTS的人可能希望使用本产品作为治疗。不能把注意力放在开发产品的美学或视觉吸引力上。我们成功开发了一种非常舒适的手套,集成了TENS电极,可以适应各种尺寸,没有任何性别规格,以经济有效的方式减轻CTS问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of wearable system for carpal tunnel syndrome
Purpose Carpal tunnel syndrome (CTS) is a hand disease caused by the pressing of the median nerve present in the palmar side of the wrist. It causes severe pain in the wrist, triggering disturbance during sleep. Different products like splints, braces and gloves are available in the market to alleviate this disease but there was still a need to improve the wearability, comfort and cost of the product. This study was about designing a comfortable and cost-effective wearable system for mild-to-moderate CTS. Transcutaneous electrical nerve stimulation (TENS) therapy has been used to reduce the pain in the wrist. Design/methodology/approach After simulation by using Proteus software (which allowed the researchers to draw and simulate electrical circuits using ISIS, ARES and PCB design tools virtually), the circuit with optimum frequency, i.e. 33 Hz was selected, and the circuit was developed on a printed circuit board (PCB). The developed circuit was integrated successfully into the half glove structure. Findings The developed product had good thermophysiological comfort and hand properties as compared to the commercially available product of the same kind. In vivo testing (It involves the testing with living subjects like animals, plants or human beings) was performed which resulted in 85% confirmed viability of the product against CTS. A glove with an integrated circuit was developed successfully to accommodate various sizes without any sex specifications in a cost-effective way to mitigate the issue of CTS. Research limitations/implications Industrial workers, individuals frequently using their hands or those diagnosed with CTS may wish to use this product as therapy. The attention could not be paid to the aesthetic or visual appeal of the developed product. Originality/value A very comfortable glove with integrated TENS electrodes was developed successfully to accommodate various sizes without any sex specifications in a cost-effective way to mitigate the issues of CTS.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Research journal of textile and apparel
Research journal of textile and apparel MATERIALS SCIENCE, TEXTILES-
CiteScore
2.90
自引率
13.30%
发文量
46
期刊最新文献
Modification of dehydrated bacterial cellulose with glycerol and succinic acid by using padding method for textile applications Key terms and topics of muscle-supportive and posture-corrective wearable robots for older adults using text mining and semantic network analyses Physical, thermal and mechanical properties of horse tail and mane hairs Enzymatic easing of adhesion in honeydew-contaminated cotton for textile applications Identification of bioactive compounds from onion (Allium burdickii) bulb using Raman, and FTIR spectroscopy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1