三维经食管超声心动图数据3D打印主动脉根部模型的可行性——与CT对比的初步研究

Wanwan Song, Yuan-ting Yang, Qing Zhou, Hong-ning Song, Bo Hu, Juan Guo, Jun Xia, Xinping Min, Zhoufeng Peng, R. Guo
{"title":"三维经食管超声心动图数据3D打印主动脉根部模型的可行性——与CT对比的初步研究","authors":"Wanwan Song, Yuan-ting Yang, Qing Zhou, Hong-ning Song, Bo Hu, Juan Guo, Jun Xia, Xinping Min, Zhoufeng Peng, R. Guo","doi":"10.3760/CMA.J.ISSN.1004-4477.2019.10.003","DOIUrl":null,"url":null,"abstract":"Objective \nTo preliminary explore the feasibility of three-dimensional transesophageal echocardiography (3D-TEE) as images data source for 3D printing model by comparing the 3D-TEE with CT of the aortic root Digital Imaging and Communications in Medicine(DICOM) data into 3D printing models respectively. \n \n \nMethods \nFifteen patients who underwent surgical aortic valve replacement in the hospital were enrolled, and the aortic root 3D-TEE and CT DICOM data were obtained in perioperative. The images were imported into Mimics software to generate digital model standard tessellation language file, and to print the aortic root models by 3D printer. The structural morphology of both 3D-TEE and CT models were qualitatively evaluated respectively. The aortic annular area, perimeter, maximal diameter and minimal diameter of the original data, digital model, model and aortic valve replacement were quantitatively evaluated, and the consistency of each parameter value were analyzed. The mean diameter of 3D-TEE and CT model were calculated. The correlation of mean diameter with the number of replacement was analyzed. \n \n \nResults \n①Both 3D-TEE and CT images data were successfully printed into 3D models, and the positive rate of aortic valve structure were 93.3% (14/15) and 80.0% (12/15) respectively. ②The measured values of the aortic annular 3D-TEE and digital model were smaller than CT, CTdigital model and replacement (P 0.95, P<0.05). \n \n \nConclusions \n3D printing aortic root model based on 3D-TEE image data is of high feasibility. \n \n \nKey words: \nEchocardiography, three-dimensional, transesophageal; Aortic root; Valve; 3D printing","PeriodicalId":10224,"journal":{"name":"中华超声影像学杂志","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The feasibility of 3D printing aortic root model by three dimensional transesophageal echocardiography data: a preliminary study compared with CT\",\"authors\":\"Wanwan Song, Yuan-ting Yang, Qing Zhou, Hong-ning Song, Bo Hu, Juan Guo, Jun Xia, Xinping Min, Zhoufeng Peng, R. Guo\",\"doi\":\"10.3760/CMA.J.ISSN.1004-4477.2019.10.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective \\nTo preliminary explore the feasibility of three-dimensional transesophageal echocardiography (3D-TEE) as images data source for 3D printing model by comparing the 3D-TEE with CT of the aortic root Digital Imaging and Communications in Medicine(DICOM) data into 3D printing models respectively. \\n \\n \\nMethods \\nFifteen patients who underwent surgical aortic valve replacement in the hospital were enrolled, and the aortic root 3D-TEE and CT DICOM data were obtained in perioperative. The images were imported into Mimics software to generate digital model standard tessellation language file, and to print the aortic root models by 3D printer. The structural morphology of both 3D-TEE and CT models were qualitatively evaluated respectively. The aortic annular area, perimeter, maximal diameter and minimal diameter of the original data, digital model, model and aortic valve replacement were quantitatively evaluated, and the consistency of each parameter value were analyzed. The mean diameter of 3D-TEE and CT model were calculated. The correlation of mean diameter with the number of replacement was analyzed. \\n \\n \\nResults \\n①Both 3D-TEE and CT images data were successfully printed into 3D models, and the positive rate of aortic valve structure were 93.3% (14/15) and 80.0% (12/15) respectively. ②The measured values of the aortic annular 3D-TEE and digital model were smaller than CT, CTdigital model and replacement (P 0.95, P<0.05). \\n \\n \\nConclusions \\n3D printing aortic root model based on 3D-TEE image data is of high feasibility. \\n \\n \\nKey words: \\nEchocardiography, three-dimensional, transesophageal; Aortic root; Valve; 3D printing\",\"PeriodicalId\":10224,\"journal\":{\"name\":\"中华超声影像学杂志\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华超声影像学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.1004-4477.2019.10.003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华超声影像学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1004-4477.2019.10.003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的通过比较三维经食管超声心动图(3D-TEE)和CT将主动脉根数字成像与医学通信(DICOM)数据分别转换为3D打印模型,初步探讨3D-TEE作为3D打印模型图像数据源的可行性。方法对15例在医院行主动脉瓣置换术的患者进行围手术期主动脉根部3D-TEE和CT DICOM数据采集。将图像导入Mimics软件,生成数字模型标准镶嵌语言文件,并通过3D打印机打印主动脉根部模型。分别对3D-TEE和CT模型的结构形态进行了定性评价。对原始数据、数字模型、模型和主动脉瓣置换术的主动脉环面积、周长、最大直径和最小直径进行了定量评估,并分析了各参数值的一致性。计算3D-TEE和CT模型的平均直径。分析了平均直径与置换次数的相关性。结果①3D-TEE和CT图像数据均成功打印成三维模型,主动脉瓣结构的阳性率分别为93.3%(14/15)和80.0%(12/15)主动脉环3D-TEE和数字模型的测量值均小于CT、CT数字模型和置换术(P 0.95,P<0.05)。关键词:超声心动图,三维,经食道;主动脉根部;阀门;3D打印
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The feasibility of 3D printing aortic root model by three dimensional transesophageal echocardiography data: a preliminary study compared with CT
Objective To preliminary explore the feasibility of three-dimensional transesophageal echocardiography (3D-TEE) as images data source for 3D printing model by comparing the 3D-TEE with CT of the aortic root Digital Imaging and Communications in Medicine(DICOM) data into 3D printing models respectively. Methods Fifteen patients who underwent surgical aortic valve replacement in the hospital were enrolled, and the aortic root 3D-TEE and CT DICOM data were obtained in perioperative. The images were imported into Mimics software to generate digital model standard tessellation language file, and to print the aortic root models by 3D printer. The structural morphology of both 3D-TEE and CT models were qualitatively evaluated respectively. The aortic annular area, perimeter, maximal diameter and minimal diameter of the original data, digital model, model and aortic valve replacement were quantitatively evaluated, and the consistency of each parameter value were analyzed. The mean diameter of 3D-TEE and CT model were calculated. The correlation of mean diameter with the number of replacement was analyzed. Results ①Both 3D-TEE and CT images data were successfully printed into 3D models, and the positive rate of aortic valve structure were 93.3% (14/15) and 80.0% (12/15) respectively. ②The measured values of the aortic annular 3D-TEE and digital model were smaller than CT, CTdigital model and replacement (P 0.95, P<0.05). Conclusions 3D printing aortic root model based on 3D-TEE image data is of high feasibility. Key words: Echocardiography, three-dimensional, transesophageal; Aortic root; Valve; 3D printing
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中华超声影像学杂志
中华超声影像学杂志 Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
0.80
自引率
0.00%
发文量
9126
期刊介绍:
期刊最新文献
Ultrasound-guided pathological sampling of cadaver lung tissue in cases of COVID-19 Ultrasound-guided post-mortem tissue sampling in the autopsy of COVID-19 cases: a pilot study The clinical value of ultrasound in the assessment of the severity of COVID-19 Study of positioning of fetal conus medullaris by detecting atlanto-axial intervertebral space with three-dimensional ultrasound Prenatal ultrasound diagnostic clues of congenital dislocation of the knee
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1