利用核心升温治疗2019冠状病毒病(COVID-19):一个初始数学模型

M. Mercado-Montoya, N. Bonfanti, E. Gundert, A. Drewry, R. Bedimo, V. Kostov, K. Kostov, Shailee Shah, E. Kulstad
{"title":"利用核心升温治疗2019冠状病毒病(COVID-19):一个初始数学模型","authors":"M. Mercado-Montoya, N. Bonfanti, E. Gundert, A. Drewry, R. Bedimo, V. Kostov, K. Kostov, Shailee Shah, E. Kulstad","doi":"10.24207/jca.v33i1.3382","DOIUrl":null,"url":null,"abstract":"Background: Increasing data suggest that elevated body temperature may be helpful in resolving a variety of diseases, including sepsis, acute respiratory distress syndrome (ARDS), and viral illnesses. SARS-CoV-2, which causes coronavirus disease 2019 (COVID-19), may be more temperature sensitive than other coronaviruses, particularly with respect to the binding affinity of its viral entry via the ACE2 receptor. A mechanical provision of elevated temperature focused in a body region of high viral activity in patients undergoing mechanical ventilation may offer a therapeutic option that avoids arrhythmias seen with some pharmaceutical treatments. We investigated the potential to actively provide core warming to the lungs of patients with a commercially available heat transfer device via mathematical modeling, and examine the influence of blood perfusion on temperature using this approach. Methods: Using the software Comsol Multiphysics, we modeled and simulated heat transfer in the body from an intraesophageal warming device, taking into account the airflow from patient ventilation. The simulation was focused on heat transfer and warming of the lungs and performed on a simplified geometry of an adult human body and airway from the pharynx to the lungs. Results: The simulations were run over a range of values for blood perfusion rate, which was a parameter expected to have high influence in overall heat transfer, since the heat capacity and density remain almost constant. The simulation results show a temperature distribution which agrees with the expected clinical experience, with the skin surface at a lower temperature than the rest of the body due to convective cooling in a typical hospital environment. The highest temperature in this case is the device warming water temperature, and that heat diffuses by conduction to the nearby tissues, including the air flowing in the airways. At the range of blood perfusion investigated, maximum lung temperature ranged from 37.6°C to 38.6°C. Conclusions: The provision of core warming via commercially available technology currently utilized in the intensive care unit, emergency department, and operating room can increase regional temperature of lung tissue and airway passages. This warming may offer an innovative approach to treating infectious diseases from viral illnesses such as COVID-19, while avoiding the arrhythmogenic complications of currently used pharmaceutical treatments.","PeriodicalId":33934,"journal":{"name":"Journal of Cardiac Arrhythmias","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The Use of Core Warming as a Treatment for Coronavirus Disease 2019 (COVID-19): an Initial Mathematical Model\",\"authors\":\"M. Mercado-Montoya, N. Bonfanti, E. Gundert, A. Drewry, R. Bedimo, V. Kostov, K. Kostov, Shailee Shah, E. Kulstad\",\"doi\":\"10.24207/jca.v33i1.3382\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Increasing data suggest that elevated body temperature may be helpful in resolving a variety of diseases, including sepsis, acute respiratory distress syndrome (ARDS), and viral illnesses. SARS-CoV-2, which causes coronavirus disease 2019 (COVID-19), may be more temperature sensitive than other coronaviruses, particularly with respect to the binding affinity of its viral entry via the ACE2 receptor. A mechanical provision of elevated temperature focused in a body region of high viral activity in patients undergoing mechanical ventilation may offer a therapeutic option that avoids arrhythmias seen with some pharmaceutical treatments. We investigated the potential to actively provide core warming to the lungs of patients with a commercially available heat transfer device via mathematical modeling, and examine the influence of blood perfusion on temperature using this approach. Methods: Using the software Comsol Multiphysics, we modeled and simulated heat transfer in the body from an intraesophageal warming device, taking into account the airflow from patient ventilation. The simulation was focused on heat transfer and warming of the lungs and performed on a simplified geometry of an adult human body and airway from the pharynx to the lungs. Results: The simulations were run over a range of values for blood perfusion rate, which was a parameter expected to have high influence in overall heat transfer, since the heat capacity and density remain almost constant. The simulation results show a temperature distribution which agrees with the expected clinical experience, with the skin surface at a lower temperature than the rest of the body due to convective cooling in a typical hospital environment. The highest temperature in this case is the device warming water temperature, and that heat diffuses by conduction to the nearby tissues, including the air flowing in the airways. At the range of blood perfusion investigated, maximum lung temperature ranged from 37.6°C to 38.6°C. Conclusions: The provision of core warming via commercially available technology currently utilized in the intensive care unit, emergency department, and operating room can increase regional temperature of lung tissue and airway passages. This warming may offer an innovative approach to treating infectious diseases from viral illnesses such as COVID-19, while avoiding the arrhythmogenic complications of currently used pharmaceutical treatments.\",\"PeriodicalId\":33934,\"journal\":{\"name\":\"Journal of Cardiac Arrhythmias\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiac Arrhythmias\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24207/jca.v33i1.3382\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiac Arrhythmias","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24207/jca.v33i1.3382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

背景:越来越多的数据表明,体温升高可能有助于解决各种疾病,包括败血症、急性呼吸窘迫综合征(ARDS)和病毒性疾病。导致2019冠状病毒病(新冠肺炎)的SARS-CoV-2可能比其他冠状病毒对温度更敏感,特别是在其通过ACE2受体进入病毒的结合亲和力方面。在接受机械通气的患者中,集中在病毒活性高的身体区域的机械提供升高的温度可能提供一种治疗选择,可以避免一些药物治疗中出现的心律失常。我们通过数学建模研究了使用商用传热设备为患者肺部主动提供核心加温的潜力,并使用这种方法检查了血液灌注对温度的影响。方法:使用Comsol Multiphysics软件,考虑到患者通气的气流,我们对食管内加温装置在体内的传热进行了建模和模拟。模拟的重点是肺部的热传递和变暖,并在成人身体和从咽部到肺部的气道的简化几何结构上进行。结果:模拟是在血液灌注率的一系列值上运行的,由于热容和密度几乎保持不变,预计血液灌注率是一个对整体传热有很大影响的参数。模拟结果显示了与预期临床经验一致的温度分布,在典型的医院环境中,由于对流冷却,皮肤表面的温度低于身体其他部位。在这种情况下,最高温度是设备加热水的温度,热量通过传导扩散到附近的组织,包括在气道中流动的空气。在所研究的血液灌注范围内,最高肺部温度在37.6°C至38.6°C之间。结论:通过目前在重症监护室、急诊室和手术室使用的商用技术提供核心加温可以提高肺组织和气道通道的区域温度。这种变暖可能为治疗新冠肺炎等病毒性疾病带来的传染病提供了一种创新的方法,同时避免了目前使用的药物治疗的致心律失常并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Use of Core Warming as a Treatment for Coronavirus Disease 2019 (COVID-19): an Initial Mathematical Model
Background: Increasing data suggest that elevated body temperature may be helpful in resolving a variety of diseases, including sepsis, acute respiratory distress syndrome (ARDS), and viral illnesses. SARS-CoV-2, which causes coronavirus disease 2019 (COVID-19), may be more temperature sensitive than other coronaviruses, particularly with respect to the binding affinity of its viral entry via the ACE2 receptor. A mechanical provision of elevated temperature focused in a body region of high viral activity in patients undergoing mechanical ventilation may offer a therapeutic option that avoids arrhythmias seen with some pharmaceutical treatments. We investigated the potential to actively provide core warming to the lungs of patients with a commercially available heat transfer device via mathematical modeling, and examine the influence of blood perfusion on temperature using this approach. Methods: Using the software Comsol Multiphysics, we modeled and simulated heat transfer in the body from an intraesophageal warming device, taking into account the airflow from patient ventilation. The simulation was focused on heat transfer and warming of the lungs and performed on a simplified geometry of an adult human body and airway from the pharynx to the lungs. Results: The simulations were run over a range of values for blood perfusion rate, which was a parameter expected to have high influence in overall heat transfer, since the heat capacity and density remain almost constant. The simulation results show a temperature distribution which agrees with the expected clinical experience, with the skin surface at a lower temperature than the rest of the body due to convective cooling in a typical hospital environment. The highest temperature in this case is the device warming water temperature, and that heat diffuses by conduction to the nearby tissues, including the air flowing in the airways. At the range of blood perfusion investigated, maximum lung temperature ranged from 37.6°C to 38.6°C. Conclusions: The provision of core warming via commercially available technology currently utilized in the intensive care unit, emergency department, and operating room can increase regional temperature of lung tissue and airway passages. This warming may offer an innovative approach to treating infectious diseases from viral illnesses such as COVID-19, while avoiding the arrhythmogenic complications of currently used pharmaceutical treatments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
5
审稿时长
6 weeks
期刊最新文献
Atrioventricular Nodal Reentrant Tachycardia in Kartagener’s Syndrome Evolution of Cardiac Arrythmia Management by Catheter Ablation in Tanzania What are the characteristics and results of Tilt Tests in the elderly? The Tilt Test in the Assessment of Syncope and Pre-syncope. Effective and safe? Analysis of a Series of 2364 Patients over 6 Years Lead Dislodgement Post Invasive Hemodynamic Assessment after Atrioventricular Node Ablation and Biventricular Pacemaker
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1