{"title":"电阻器中的零点热噪声?结论","authors":"L. Kish","doi":"10.24425/MMS.2019.126337","DOIUrl":null,"url":null,"abstract":"The main points of the UPoN-2018 talk and some valuable comments from the Audience are briefly summarized. The talk surveyed the major issues with the notion of zero-point thermal noise in resistors and its visibility; moreover it gave some new arguments. The new arguments support the old view of Kleen that the known measurement data “showing” zero-point Johnson noise are instrumental artifacts caused by the energy-time uncertainty principle. We pointed out that, during the spectral analysis of blackbody radiation, another uncertainty principle is relevant, that is, the location-momentum uncertainty principle that causes only the widening of spectral lines instead of the zero-point noise artifact. This is the reason why the Planck formula is correctly confirmed by the blackbody radiation experiments. Finally a conjecture about the zero-point noise spectrum of wide-band amplifiers is shown, but that is yet to be tested experimentally.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Zero-point thermal noise in resistors? A conclusion\",\"authors\":\"L. Kish\",\"doi\":\"10.24425/MMS.2019.126337\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main points of the UPoN-2018 talk and some valuable comments from the Audience are briefly summarized. The talk surveyed the major issues with the notion of zero-point thermal noise in resistors and its visibility; moreover it gave some new arguments. The new arguments support the old view of Kleen that the known measurement data “showing” zero-point Johnson noise are instrumental artifacts caused by the energy-time uncertainty principle. We pointed out that, during the spectral analysis of blackbody radiation, another uncertainty principle is relevant, that is, the location-momentum uncertainty principle that causes only the widening of spectral lines instead of the zero-point noise artifact. This is the reason why the Planck formula is correctly confirmed by the blackbody radiation experiments. Finally a conjecture about the zero-point noise spectrum of wide-band amplifiers is shown, but that is yet to be tested experimentally.\",\"PeriodicalId\":18394,\"journal\":{\"name\":\"Metrology and Measurement Systems\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-07-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metrology and Measurement Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.24425/MMS.2019.126337\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrology and Measurement Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.24425/MMS.2019.126337","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
Zero-point thermal noise in resistors? A conclusion
The main points of the UPoN-2018 talk and some valuable comments from the Audience are briefly summarized. The talk surveyed the major issues with the notion of zero-point thermal noise in resistors and its visibility; moreover it gave some new arguments. The new arguments support the old view of Kleen that the known measurement data “showing” zero-point Johnson noise are instrumental artifacts caused by the energy-time uncertainty principle. We pointed out that, during the spectral analysis of blackbody radiation, another uncertainty principle is relevant, that is, the location-momentum uncertainty principle that causes only the widening of spectral lines instead of the zero-point noise artifact. This is the reason why the Planck formula is correctly confirmed by the blackbody radiation experiments. Finally a conjecture about the zero-point noise spectrum of wide-band amplifiers is shown, but that is yet to be tested experimentally.
期刊介绍:
Contributions are invited on all aspects of the research, development and applications of the measurement science and technology.
The list of topics covered includes: theory and general principles of measurement; measurement of physical, chemical and biological quantities; medical measurements; sensors and transducers; measurement data acquisition; measurement signal transmission; processing and data analysis; measurement systems and embedded systems; design, manufacture and evaluation of instruments.
The average publication cycle is 6 months.