不同室内实践中管道水中残余三卤甲烷浓度的变化

IF 1.6 Q3 WATER RESOURCES Water Practice and Technology Pub Date : 2023-03-07 DOI:10.2166/wpt.2023.032
Nepali Jayasinghe, Dilini Chandima Herath, Lalith Indranath Weerasekara, Sujithra Kaushalya Weragoda, Gayan Darshana Amarasooriya
{"title":"不同室内实践中管道水中残余三卤甲烷浓度的变化","authors":"Nepali Jayasinghe, Dilini Chandima Herath, Lalith Indranath Weerasekara, Sujithra Kaushalya Weragoda, Gayan Darshana Amarasooriya","doi":"10.2166/wpt.2023.032","DOIUrl":null,"url":null,"abstract":"\n This study was conducted to investigate the effect of different in-house practices on trihalomethane (THM) level fluctuations in pipe-borne water. Common in-house practices such as boiling, unboiling, boiling water with headspace/non-headspace, storage vessels materials, storage practices, and storage time were investigated to study residual THM and their percentage. Vessels made of plastic (P), clay (C), stainless steel (SS), glass (G), and aluminium (Al) were used for the study. Prime trihalomethanes of CHCl3, CHBrCl2, CHBr2Cl, CHBr3, and total of those four THMs (TTHMs) were measured, and removal/formation percentages were calculated. Results revealed that the percent change of TTHM varies based on the boiling practice as follows: open boiling TTHM > close boiling with headspace TTHM > close boiling without headspace (CBWH) TTHM. The following order was observed for residual TTHM for 6 h storage in the vessels; for CBWH water storage in open vessels C < G < P < SS < Al and close vessels C < G < P < SS < Al; and for un-boiled water storage in open vessels SS < C < Al < P < G and close vessels C < P < Al < SS < G. In conclusion, the lowest concentration of residual TTHM was found in the boiled water stored in a clay pot and recommended as an in-house practice to reduce TTHM.","PeriodicalId":23794,"journal":{"name":"Water Practice and Technology","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2023-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Variations of residual trihalomethane concentration in pipe-borne water during different in-house practices\",\"authors\":\"Nepali Jayasinghe, Dilini Chandima Herath, Lalith Indranath Weerasekara, Sujithra Kaushalya Weragoda, Gayan Darshana Amarasooriya\",\"doi\":\"10.2166/wpt.2023.032\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n This study was conducted to investigate the effect of different in-house practices on trihalomethane (THM) level fluctuations in pipe-borne water. Common in-house practices such as boiling, unboiling, boiling water with headspace/non-headspace, storage vessels materials, storage practices, and storage time were investigated to study residual THM and their percentage. Vessels made of plastic (P), clay (C), stainless steel (SS), glass (G), and aluminium (Al) were used for the study. Prime trihalomethanes of CHCl3, CHBrCl2, CHBr2Cl, CHBr3, and total of those four THMs (TTHMs) were measured, and removal/formation percentages were calculated. Results revealed that the percent change of TTHM varies based on the boiling practice as follows: open boiling TTHM > close boiling with headspace TTHM > close boiling without headspace (CBWH) TTHM. The following order was observed for residual TTHM for 6 h storage in the vessels; for CBWH water storage in open vessels C < G < P < SS < Al and close vessels C < G < P < SS < Al; and for un-boiled water storage in open vessels SS < C < Al < P < G and close vessels C < P < Al < SS < G. In conclusion, the lowest concentration of residual TTHM was found in the boiled water stored in a clay pot and recommended as an in-house practice to reduce TTHM.\",\"PeriodicalId\":23794,\"journal\":{\"name\":\"Water Practice and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Water Practice and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2166/wpt.2023.032\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"WATER RESOURCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Practice and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/wpt.2023.032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"WATER RESOURCES","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在探讨不同的室内操作对管道水中三卤甲烷(THM)水平波动的影响。调查了常见的内部操作,如煮沸、未煮沸、沸水顶空/非顶空、存储容器材料、存储操作和存储时间,以研究残余THM及其百分比。研究中使用了塑料(P)、粘土(C)、不锈钢(SS)、玻璃(G)和铝(Al)制成的容器。测定CHCl3、CHBrCl2、CHBr2Cl、CHBr3及其四种THMs (TTHMs)的质数三卤甲烷,并计算其去除率/成形率。结果表明,不同沸腾方式下,TTHM的百分比变化如下:开煮TTHM >带顶空闭煮TTHM >无顶空(CBWH)闭煮TTHM。剩余TTHM在容器中储存6小时的顺序如下:开放容器C < G < P < SS < Al,封闭容器C < G < P < SS < Al;对于未煮沸的水,开放容器中SS < C < Al < P < G,封闭容器中C < P < Al < SS < G。综上所述,在陶罐中储存的沸水中,TTHM残留浓度最低,建议作为室内实践来减少TTHM。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Variations of residual trihalomethane concentration in pipe-borne water during different in-house practices
This study was conducted to investigate the effect of different in-house practices on trihalomethane (THM) level fluctuations in pipe-borne water. Common in-house practices such as boiling, unboiling, boiling water with headspace/non-headspace, storage vessels materials, storage practices, and storage time were investigated to study residual THM and their percentage. Vessels made of plastic (P), clay (C), stainless steel (SS), glass (G), and aluminium (Al) were used for the study. Prime trihalomethanes of CHCl3, CHBrCl2, CHBr2Cl, CHBr3, and total of those four THMs (TTHMs) were measured, and removal/formation percentages were calculated. Results revealed that the percent change of TTHM varies based on the boiling practice as follows: open boiling TTHM > close boiling with headspace TTHM > close boiling without headspace (CBWH) TTHM. The following order was observed for residual TTHM for 6 h storage in the vessels; for CBWH water storage in open vessels C < G < P < SS < Al and close vessels C < G < P < SS < Al; and for un-boiled water storage in open vessels SS < C < Al < P < G and close vessels C < P < Al < SS < G. In conclusion, the lowest concentration of residual TTHM was found in the boiled water stored in a clay pot and recommended as an in-house practice to reduce TTHM.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
6.20%
发文量
136
审稿时长
14 weeks
期刊最新文献
Hydro-geochemical characterisation and modelling of groundwater in Chikun Local Government Area of Kaduna state, Nigeria A methodology for temporal disaggregation of daily rain gauge data using satellite precipitation product for improved accuracy in hydrologic simulation ACWA: an AI-driven cyber-physical testbed for intelligent water systems Phosphorus removal from ore waste in aqueous solution with different mass of ore waste adsorbent from the Johor mine site Assessment of risks to the quality of water supplied in Bushenyi-Uganda using the water safety plan approach
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1