{"title":"羟基磷灰石(HAp)涂层人工股骨假体脆性断裂扩展行为的预测","authors":"C. Sheng, Nagentrau Muniandy, N. H. Ibrahim","doi":"10.5604/01.3001.0015.9851","DOIUrl":null,"url":null,"abstract":"Purpose: This study addresses the brittle fracture propagation behaviour modelling of hydroxyapatite (HAp) coating in artificial femoral stem component.\n\nDesign/methodology/approach: A simple two dimensional flat-on-flat contact configuration finite element model consisting contact pad (bone), Ti-6Al-4V substrate and HAp coating is employed in static simulation. The HAp coating is modelled as elastic layer with pre-microcrack which assumed to be initiated due to stress singularity.\n\nFindings: The study revealed that reducing coating thickness, pre-microcrack length and artificial femoral stem elastic modulus along with increasing bone elastic modulus will result in significant stress intensity factor (SIF) to promote brittle fracture propagation behaviour.\n\nResearch limitations/implications: The influence of coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus on fracture behaviour is examined under different stress ratio using J-integral analysis approach.\n\nPractical implications: The proposed finite element model can be easily accommodating different Hap coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus to perform detailed parametric studies with minimal costly experimental works.\n\nOriginality/value: Limited research focussing on brittle fracture propagation behaviour of HAp coating in artificial femoral stem component. Thus, present study analysed the influence of coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus on stress intensity factor (SIF) of HAp coating.\n\n","PeriodicalId":8297,"journal":{"name":"Archives of materials science and engineering","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Prediction of brittle fracture propagation behaviour of hydroxyapatite (HAp) coating in artificial femoral stem component\",\"authors\":\"C. Sheng, Nagentrau Muniandy, N. H. Ibrahim\",\"doi\":\"10.5604/01.3001.0015.9851\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: This study addresses the brittle fracture propagation behaviour modelling of hydroxyapatite (HAp) coating in artificial femoral stem component.\\n\\nDesign/methodology/approach: A simple two dimensional flat-on-flat contact configuration finite element model consisting contact pad (bone), Ti-6Al-4V substrate and HAp coating is employed in static simulation. The HAp coating is modelled as elastic layer with pre-microcrack which assumed to be initiated due to stress singularity.\\n\\nFindings: The study revealed that reducing coating thickness, pre-microcrack length and artificial femoral stem elastic modulus along with increasing bone elastic modulus will result in significant stress intensity factor (SIF) to promote brittle fracture propagation behaviour.\\n\\nResearch limitations/implications: The influence of coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus on fracture behaviour is examined under different stress ratio using J-integral analysis approach.\\n\\nPractical implications: The proposed finite element model can be easily accommodating different Hap coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus to perform detailed parametric studies with minimal costly experimental works.\\n\\nOriginality/value: Limited research focussing on brittle fracture propagation behaviour of HAp coating in artificial femoral stem component. Thus, present study analysed the influence of coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus on stress intensity factor (SIF) of HAp coating.\\n\\n\",\"PeriodicalId\":8297,\"journal\":{\"name\":\"Archives of materials science and engineering\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of materials science and engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5604/01.3001.0015.9851\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Materials Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of materials science and engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0015.9851","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Materials Science","Score":null,"Total":0}
Prediction of brittle fracture propagation behaviour of hydroxyapatite (HAp) coating in artificial femoral stem component
Purpose: This study addresses the brittle fracture propagation behaviour modelling of hydroxyapatite (HAp) coating in artificial femoral stem component.
Design/methodology/approach: A simple two dimensional flat-on-flat contact configuration finite element model consisting contact pad (bone), Ti-6Al-4V substrate and HAp coating is employed in static simulation. The HAp coating is modelled as elastic layer with pre-microcrack which assumed to be initiated due to stress singularity.
Findings: The study revealed that reducing coating thickness, pre-microcrack length and artificial femoral stem elastic modulus along with increasing bone elastic modulus will result in significant stress intensity factor (SIF) to promote brittle fracture propagation behaviour.
Research limitations/implications: The influence of coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus on fracture behaviour is examined under different stress ratio using J-integral analysis approach.
Practical implications: The proposed finite element model can be easily accommodating different Hap coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus to perform detailed parametric studies with minimal costly experimental works.
Originality/value: Limited research focussing on brittle fracture propagation behaviour of HAp coating in artificial femoral stem component. Thus, present study analysed the influence of coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus on stress intensity factor (SIF) of HAp coating.