生物相容性形态学平均试验测定乳胶手套中的蛋白质浓度

C. Toa, K. S. Sim, Y. Chan
{"title":"生物相容性形态学平均试验测定乳胶手套中的蛋白质浓度","authors":"C. Toa, K. S. Sim, Y. Chan","doi":"10.33093/ijoras.2020.2.3","DOIUrl":null,"url":null,"abstract":"Latex gloves are seen as an indispensable item in the healthcare field because it offers superior protection for both the medical staff and patient against harmful substances. However, latex gloves with high protein concentration have a high possibility to induce latex allergy which in the worst case can lead to a life-threatening condition. To minimize the occurrence of an allergy reaction, the computerized Biocompatibility Morphological Mean (BMM) test for protein detection is proposed. This test initially goes through the chemical process to determine the protein that resides in the glove sample. After that, the sample is electronically converted into a digital image. Finally, the image undergoes color image processing for calculating the color difference values. These values are then plotted on a standard curve. A high correlation coefficient (R2>0.97) of the standard curve gives better accuracies. The proposed method only takes about 40 minutes to complete the test, while existing methods need at least 6 hours.","PeriodicalId":73286,"journal":{"name":"IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Protein Concentration Determination in Latex Glove Using Biocompatibility Morphological Mean Test\",\"authors\":\"C. Toa, K. S. Sim, Y. Chan\",\"doi\":\"10.33093/ijoras.2020.2.3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Latex gloves are seen as an indispensable item in the healthcare field because it offers superior protection for both the medical staff and patient against harmful substances. However, latex gloves with high protein concentration have a high possibility to induce latex allergy which in the worst case can lead to a life-threatening condition. To minimize the occurrence of an allergy reaction, the computerized Biocompatibility Morphological Mean (BMM) test for protein detection is proposed. This test initially goes through the chemical process to determine the protein that resides in the glove sample. After that, the sample is electronically converted into a digital image. Finally, the image undergoes color image processing for calculating the color difference values. These values are then plotted on a standard curve. A high correlation coefficient (R2>0.97) of the standard curve gives better accuracies. The proposed method only takes about 40 minutes to complete the test, while existing methods need at least 6 hours.\",\"PeriodicalId\":73286,\"journal\":{\"name\":\"IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33093/ijoras.2020.2.3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33093/ijoras.2020.2.3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

乳胶手套被视为医疗保健领域不可或缺的物品,因为它为医护人员和患者提供了卓越的保护,使其免受有害物质的侵害。然而,高蛋白浓度的乳胶手套很有可能引发乳胶过敏,在最坏的情况下,乳胶过敏可能导致危及生命的情况。为了最大限度地减少过敏反应的发生,提出了用于蛋白质检测的计算机生物相容性形态学平均值(BMM)测试。该测试最初通过化学过程来确定手套样品中的蛋白质。之后,样本被电子转换为数字图像。最后,对图像进行彩色图像处理以计算色差值。然后将这些值绘制在标准曲线上。标准曲线的高相关系数(R2>0.97)给出了更好的精度。所提出的方法只需要大约40分钟就可以完成测试,而现有的方法至少需要6个小时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Protein Concentration Determination in Latex Glove Using Biocompatibility Morphological Mean Test
Latex gloves are seen as an indispensable item in the healthcare field because it offers superior protection for both the medical staff and patient against harmful substances. However, latex gloves with high protein concentration have a high possibility to induce latex allergy which in the worst case can lead to a life-threatening condition. To minimize the occurrence of an allergy reaction, the computerized Biocompatibility Morphological Mean (BMM) test for protein detection is proposed. This test initially goes through the chemical process to determine the protein that resides in the glove sample. After that, the sample is electronically converted into a digital image. Finally, the image undergoes color image processing for calculating the color difference values. These values are then plotted on a standard curve. A high correlation coefficient (R2>0.97) of the standard curve gives better accuracies. The proposed method only takes about 40 minutes to complete the test, while existing methods need at least 6 hours.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.80
自引率
0.00%
发文量
0
期刊最新文献
Towards a Unified Approach for Continuously-Variable Impedance Control of Powered Prosthetic Legs over Walking Speeds and Inclines. Cooperative vs. Teleoperation Control of the Steady Hand Eye Robot with Adaptive Sclera Force Control: A Comparative Study. Bevel-Tip Needle Deflection Modeling, Simulation, and Validation in Multi-Layer Tissues. Exploring the Needle Tip Interaction Force with Retinal Tissue Deformation in Vitreoretinal Surgery. Fully Distributed Shape Sensing of a Flexible Surgical Needle Using Optical Frequency Domain Reflectometry for Prostate Interventions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1