钢框架结构移动火灾试验:CFD和FEM数值研究

IF 0.9 Q4 CONSTRUCTION & BUILDING TECHNOLOGY Journal of Structural Fire Engineering Pub Date : 2021-05-21 DOI:10.1108/JSFE-11-2020-0034
M. Charlier, A. Glorieux, Xu Dai, Naveed Alam, S. Welch, Johan Anderson, O. Vassart, A. Nadjai
{"title":"钢框架结构移动火灾试验:CFD和FEM数值研究","authors":"M. Charlier, A. Glorieux, Xu Dai, Naveed Alam, S. Welch, Johan Anderson, O. Vassart, A. Nadjai","doi":"10.1108/JSFE-11-2020-0034","DOIUrl":null,"url":null,"abstract":"\nPurpose\nThe purpose of this paper is to propose a simplified representation of the fire load in computational fluid dynamics (CFD) to represent the effect of large-scale travelling fire and to highlight the relevance of such an approach whilst coupling the CFD results with finite element method (FEM) to evaluate related steel temperatures, comparing the numerical outcomes with experimental measurements.\n\n\nDesign/methodology/approach\nThis paper presents the setup of the CFD simulations (FDS software), its corresponding assumptions and the calibration via two natural fire tests whilst focusing on gas temperatures and on steel temperatures measured on a central column. For the latter, two methods are presented: one based on EN 1993-1-2 and another linking CFD and FEM (SAFIR® software).\n\n\nFindings\nThis paper suggests that such an approach can allow for an acceptable representation of the travelling fire both in terms of fire spread and steel temperatures. The inevitable limitations inherent to the simplifications made during the CFD simulations are also discussed. Regarding steel temperatures, the two methods lead to quite similar results, but with the ones obtained via CFD–FEM coupling are closer to those measured.\n\n\nOriginality/value\nThis work has revealed that the proposed simplified representation of the fire load appears to be appropriate to evaluate the temperature of steel structural elements within reasonable limits on computational time, making it potentially desirable for practical applications. This paper also presents the first comparisons of FDS–SAFIR® coupling with experimental results, highlighting promising outcomes.\n","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2021-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Travelling fire experiments in steel-framed structure: numerical investigations with CFD and FEM\",\"authors\":\"M. Charlier, A. Glorieux, Xu Dai, Naveed Alam, S. Welch, Johan Anderson, O. Vassart, A. Nadjai\",\"doi\":\"10.1108/JSFE-11-2020-0034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\nPurpose\\nThe purpose of this paper is to propose a simplified representation of the fire load in computational fluid dynamics (CFD) to represent the effect of large-scale travelling fire and to highlight the relevance of such an approach whilst coupling the CFD results with finite element method (FEM) to evaluate related steel temperatures, comparing the numerical outcomes with experimental measurements.\\n\\n\\nDesign/methodology/approach\\nThis paper presents the setup of the CFD simulations (FDS software), its corresponding assumptions and the calibration via two natural fire tests whilst focusing on gas temperatures and on steel temperatures measured on a central column. For the latter, two methods are presented: one based on EN 1993-1-2 and another linking CFD and FEM (SAFIR® software).\\n\\n\\nFindings\\nThis paper suggests that such an approach can allow for an acceptable representation of the travelling fire both in terms of fire spread and steel temperatures. The inevitable limitations inherent to the simplifications made during the CFD simulations are also discussed. Regarding steel temperatures, the two methods lead to quite similar results, but with the ones obtained via CFD–FEM coupling are closer to those measured.\\n\\n\\nOriginality/value\\nThis work has revealed that the proposed simplified representation of the fire load appears to be appropriate to evaluate the temperature of steel structural elements within reasonable limits on computational time, making it potentially desirable for practical applications. This paper also presents the first comparisons of FDS–SAFIR® coupling with experimental results, highlighting promising outcomes.\\n\",\"PeriodicalId\":45033,\"journal\":{\"name\":\"Journal of Structural Fire Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2021-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Structural Fire Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1108/JSFE-11-2020-0034\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Structural Fire Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/JSFE-11-2020-0034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 10

摘要

本文的目的是在计算流体力学(CFD)中提出一种简化的火灾负荷表示,以表示大规模行进火灾的影响,并强调这种方法的相关性,同时将CFD结果与有限元方法(FEM)相结合,以评估相关的钢温度,并将数值结果与实验测量结果进行比较。设计/方法/方法本文介绍了CFD模拟(FDS软件)的设置,其相应的假设和通过两次自然火灾测试进行的校准,同时重点关注气体温度和在中心柱上测量的钢温度。对于后者,提出了两种方法:一种基于en1993 -1-2,另一种结合CFD和FEM (SAFIR®软件)。这篇论文表明,这种方法可以在火势蔓延和钢铁温度方面对行进的火灾进行可接受的表示。文中还讨论了CFD模拟过程中所作的简化所固有的不可避免的局限性。对于钢的温度,两种方法得到的结果非常相似,但通过CFD-FEM耦合得到的结果更接近实测值。独创性/价值本研究表明,在合理的计算时间范围内,提出的简化的火灾荷载表示似乎适合于评估钢结构元件的温度,使其具有实际应用的潜力。本文还介绍了FDS-SAFIR®耦合与实验结果的首次比较,突出了有希望的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Travelling fire experiments in steel-framed structure: numerical investigations with CFD and FEM
Purpose The purpose of this paper is to propose a simplified representation of the fire load in computational fluid dynamics (CFD) to represent the effect of large-scale travelling fire and to highlight the relevance of such an approach whilst coupling the CFD results with finite element method (FEM) to evaluate related steel temperatures, comparing the numerical outcomes with experimental measurements. Design/methodology/approach This paper presents the setup of the CFD simulations (FDS software), its corresponding assumptions and the calibration via two natural fire tests whilst focusing on gas temperatures and on steel temperatures measured on a central column. For the latter, two methods are presented: one based on EN 1993-1-2 and another linking CFD and FEM (SAFIR® software). Findings This paper suggests that such an approach can allow for an acceptable representation of the travelling fire both in terms of fire spread and steel temperatures. The inevitable limitations inherent to the simplifications made during the CFD simulations are also discussed. Regarding steel temperatures, the two methods lead to quite similar results, but with the ones obtained via CFD–FEM coupling are closer to those measured. Originality/value This work has revealed that the proposed simplified representation of the fire load appears to be appropriate to evaluate the temperature of steel structural elements within reasonable limits on computational time, making it potentially desirable for practical applications. This paper also presents the first comparisons of FDS–SAFIR® coupling with experimental results, highlighting promising outcomes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Structural Fire Engineering
Journal of Structural Fire Engineering CONSTRUCTION & BUILDING TECHNOLOGY-
CiteScore
2.20
自引率
10.00%
发文量
28
期刊最新文献
Post-fire shear strengths of drilling screws and post-fire transitions of failure modes for screwed connections Combined effects of corrosion and fire on load-carrying response of hot-rolled steel reinforcement Influence of section profiles on flexural behavior of unsymmetrical cold formed steel sections – analytical and numerical investigation Estimating the elastic modulus of concrete under moderately elevated temperatures via impulse excitation technique Impact of the variability of material constitutive models on the thermal response of reinforced concrete walls
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1