新型无骨水泥全髋关节置换术。一项多中心前瞻性至少2年随访临床结果研究。

Rohit Pandey, S. Coffey, R. Sorial
{"title":"新型无骨水泥全髋关节置换术。一项多中心前瞻性至少2年随访临床结果研究。","authors":"Rohit Pandey, S. Coffey, R. Sorial","doi":"10.15438/RR.11.1.251","DOIUrl":null,"url":null,"abstract":"Background: Cementless implants were introduced approximately three decades ago in order to address aseptic loosening of cemented hip prostheses with the aim of early mobilisation, better functional result and bone stock preservation. The primary objective of this study is to introduce a new cementless HA coated implant and report its minimum 2 year follow up results.\nMaterial & method: This is a prospective, multi-centre, consecutive series, clinical outcomes study with 75 patients. Inclusion criteria for the study were age 21- 85 years, BMI <40, osteoarthritis of the hip.\nPatients were operated using a standard posterolateral approach. The Paragon stem and the Global cup were implanted in a cementless method. Patients were reviewed at 6 weeks, 6 months and two years postoperative. At each visit AQoL 6D, VAS Pain, Oxford Hip Score were recorded. Post-operative X-Rays were reviewed at immediate post-operative, 6 months and two years.\nResults: Mean duration of surgery was 63.1 min with range of 40-120 min. AQoL over time changed from pre-op mean 50.51, at 6 weeks and at 2 years mean 35.06. Oxford hip score had upward trend from pre-op to post-op 6wks assessments and a plateau in following assessments. VAS pain trajectories, showing a clear downward trend from pre-op to post-op 6wks and a plateau in the following postoperative assessments.\nDiscussion & conclusion: The combination of Paragon stem and Global cup incorporates proven features of successful implants. The unique feature of lateral tension grooves and progressive neck dimension with dual offset options. This combination has shown promising early results with early follow up of a minimum of 2 years, with a 100% survivorship of the stem and 98.7% survivorship overall for any reason and is a good cementless option in THA.","PeriodicalId":20884,"journal":{"name":"Reconstructive Review","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New Cementless Total Hip Arthroplasty. A Multicentre Prospective Minimum 2 Year Follow-up Clinical Outcomes Study.\",\"authors\":\"Rohit Pandey, S. Coffey, R. Sorial\",\"doi\":\"10.15438/RR.11.1.251\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Cementless implants were introduced approximately three decades ago in order to address aseptic loosening of cemented hip prostheses with the aim of early mobilisation, better functional result and bone stock preservation. The primary objective of this study is to introduce a new cementless HA coated implant and report its minimum 2 year follow up results.\\nMaterial & method: This is a prospective, multi-centre, consecutive series, clinical outcomes study with 75 patients. Inclusion criteria for the study were age 21- 85 years, BMI <40, osteoarthritis of the hip.\\nPatients were operated using a standard posterolateral approach. The Paragon stem and the Global cup were implanted in a cementless method. Patients were reviewed at 6 weeks, 6 months and two years postoperative. At each visit AQoL 6D, VAS Pain, Oxford Hip Score were recorded. Post-operative X-Rays were reviewed at immediate post-operative, 6 months and two years.\\nResults: Mean duration of surgery was 63.1 min with range of 40-120 min. AQoL over time changed from pre-op mean 50.51, at 6 weeks and at 2 years mean 35.06. Oxford hip score had upward trend from pre-op to post-op 6wks assessments and a plateau in following assessments. VAS pain trajectories, showing a clear downward trend from pre-op to post-op 6wks and a plateau in the following postoperative assessments.\\nDiscussion & conclusion: The combination of Paragon stem and Global cup incorporates proven features of successful implants. The unique feature of lateral tension grooves and progressive neck dimension with dual offset options. This combination has shown promising early results with early follow up of a minimum of 2 years, with a 100% survivorship of the stem and 98.7% survivorship overall for any reason and is a good cementless option in THA.\",\"PeriodicalId\":20884,\"journal\":{\"name\":\"Reconstructive Review\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Reconstructive Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15438/RR.11.1.251\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reconstructive Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15438/RR.11.1.251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:大约三十年前,为了解决骨水泥髋关节假体的无菌性松动问题,引入了无骨水泥植入物,目的是早期动员、更好的功能结果和骨储备保存。本研究的主要目的是介绍一种新型无骨水泥HA涂层植入物,并报告其至少2年的随访结果。材料和方法:这是一项前瞻性、多中心、连续系列的临床结果研究,共有75名患者。该研究的纳入标准为年龄21-85岁,BMI<40,髋关节骨性关节炎。患者采用标准后外侧入路进行手术。Paragon干和Global cup采用非骨水泥方法植入。在术后6周、6个月和2年对患者进行复查。每次就诊时记录AQoL 6D、VAS疼痛、Oxford髋关节评分。术后X光检查在术后即刻、6个月和两年进行。结果:手术的平均持续时间为63.1分钟,范围为40-120分钟。随着时间的推移,AQoL从术前的平均值50.51、6周和2年的平均值35.06变化。从术前到术后6周的评估,牛津髋关节评分呈上升趋势,随后的评估呈平稳状态。VAS疼痛轨迹,从术前到术后6周显示出明显的下降趋势,在随后的术后评估中呈平稳状态。讨论和结论:Paragon干细胞和Global cup的结合结合了成功植入的公认特征。独特的横向张力凹槽和渐进式颈部尺寸,可选择双偏置。该组合已显示出有希望的早期结果,早期随访至少2年,干细胞存活率为100%,无论出于何种原因,总存活率为98.7%,是THA的一个良好的非骨水泥选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
New Cementless Total Hip Arthroplasty. A Multicentre Prospective Minimum 2 Year Follow-up Clinical Outcomes Study.
Background: Cementless implants were introduced approximately three decades ago in order to address aseptic loosening of cemented hip prostheses with the aim of early mobilisation, better functional result and bone stock preservation. The primary objective of this study is to introduce a new cementless HA coated implant and report its minimum 2 year follow up results. Material & method: This is a prospective, multi-centre, consecutive series, clinical outcomes study with 75 patients. Inclusion criteria for the study were age 21- 85 years, BMI <40, osteoarthritis of the hip. Patients were operated using a standard posterolateral approach. The Paragon stem and the Global cup were implanted in a cementless method. Patients were reviewed at 6 weeks, 6 months and two years postoperative. At each visit AQoL 6D, VAS Pain, Oxford Hip Score were recorded. Post-operative X-Rays were reviewed at immediate post-operative, 6 months and two years. Results: Mean duration of surgery was 63.1 min with range of 40-120 min. AQoL over time changed from pre-op mean 50.51, at 6 weeks and at 2 years mean 35.06. Oxford hip score had upward trend from pre-op to post-op 6wks assessments and a plateau in following assessments. VAS pain trajectories, showing a clear downward trend from pre-op to post-op 6wks and a plateau in the following postoperative assessments. Discussion & conclusion: The combination of Paragon stem and Global cup incorporates proven features of successful implants. The unique feature of lateral tension grooves and progressive neck dimension with dual offset options. This combination has shown promising early results with early follow up of a minimum of 2 years, with a 100% survivorship of the stem and 98.7% survivorship overall for any reason and is a good cementless option in THA.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
2
审稿时长
24 weeks
期刊最新文献
Post-operative outcomes, including opioid utilization and length of stay, following total knee arthroplasty: A retrospective case matched series comparing conventional and robotic-assisted total knee arthroplasty Can Knees be Forgotten 2 Years After Total Knee Arthroplasty? Tranexamic Acid Should be Considered for High Risk Arthroplasty Patients Life Lost Too Soon: Navy Corpsman from Ohio Killed in Afghanistan Attack August 26, 2021 A Literature-Based Resource for the Development of Outpatient Arthroplasty Patient Selection Criteria
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1