{"title":"基于内腔动力学的微管拉曼微激光增益辅助传感","authors":"Mingfang Li, Zongren Dai, Mingwang Tian, Y. Tan","doi":"10.1063/5.0158302","DOIUrl":null,"url":null,"abstract":"Microcavity lasers show excellent performance as a miniaturized microsensor in various applications. However, their relatively weak power may be easily submerged in system noises and disturbed by environmental fluctuations, rendering them ineffective at detecting small signals for precise sensing. To solve this problem, the laser differential frequency-shift feedback technique is demonstrated in a microtubule Raman laser to achieve the optical gain assistance. When the microlaser is frequency-shift-modulated and returns back to the resonator, the measurement signal can resonate with the laser relaxation oscillation and be significantly enhanced. The intracavity dynamics-based enhancement makes it effective for increasing intensity changes caused by analytes. Small signals that would otherwise be buried in system noises and go undetected can be more easily resolved. In addition, the microsensor reduces the spectral measurement range and offers a way to observe the fast dynamic response. Based on that, a measurement resolution of 50 nm nanoparticle detection limit and a refractive index noise-limited resolution of 8.18 × 10−7 refractive index unit (RIU) are demonstrated. The dynamic phase transition of thermosensitive hydrogel is further investigated as a validation of its rapid detection capability. Integrated with an inherent microfluidic channel, the proposed microsensor provides a direct interaction between analytes and probe light with ultrasmall sample consumption down to 50 pl. It is expected to boost the detection of weak signals in microlasers and enlighten the development of optofluidic microsensors in exploring diverse biochemical processes.","PeriodicalId":8198,"journal":{"name":"APL Photonics","volume":" ","pages":""},"PeriodicalIF":5.4000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Intracavity dynamics-based gain-assisted sensing with microtubule Raman microlaser\",\"authors\":\"Mingfang Li, Zongren Dai, Mingwang Tian, Y. Tan\",\"doi\":\"10.1063/5.0158302\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Microcavity lasers show excellent performance as a miniaturized microsensor in various applications. However, their relatively weak power may be easily submerged in system noises and disturbed by environmental fluctuations, rendering them ineffective at detecting small signals for precise sensing. To solve this problem, the laser differential frequency-shift feedback technique is demonstrated in a microtubule Raman laser to achieve the optical gain assistance. When the microlaser is frequency-shift-modulated and returns back to the resonator, the measurement signal can resonate with the laser relaxation oscillation and be significantly enhanced. The intracavity dynamics-based enhancement makes it effective for increasing intensity changes caused by analytes. Small signals that would otherwise be buried in system noises and go undetected can be more easily resolved. In addition, the microsensor reduces the spectral measurement range and offers a way to observe the fast dynamic response. Based on that, a measurement resolution of 50 nm nanoparticle detection limit and a refractive index noise-limited resolution of 8.18 × 10−7 refractive index unit (RIU) are demonstrated. The dynamic phase transition of thermosensitive hydrogel is further investigated as a validation of its rapid detection capability. Integrated with an inherent microfluidic channel, the proposed microsensor provides a direct interaction between analytes and probe light with ultrasmall sample consumption down to 50 pl. It is expected to boost the detection of weak signals in microlasers and enlighten the development of optofluidic microsensors in exploring diverse biochemical processes.\",\"PeriodicalId\":8198,\"journal\":{\"name\":\"APL Photonics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"APL Photonics\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0158302\",\"RegionNum\":1,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"APL Photonics","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1063/5.0158302","RegionNum":1,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPTICS","Score":null,"Total":0}
Intracavity dynamics-based gain-assisted sensing with microtubule Raman microlaser
Microcavity lasers show excellent performance as a miniaturized microsensor in various applications. However, their relatively weak power may be easily submerged in system noises and disturbed by environmental fluctuations, rendering them ineffective at detecting small signals for precise sensing. To solve this problem, the laser differential frequency-shift feedback technique is demonstrated in a microtubule Raman laser to achieve the optical gain assistance. When the microlaser is frequency-shift-modulated and returns back to the resonator, the measurement signal can resonate with the laser relaxation oscillation and be significantly enhanced. The intracavity dynamics-based enhancement makes it effective for increasing intensity changes caused by analytes. Small signals that would otherwise be buried in system noises and go undetected can be more easily resolved. In addition, the microsensor reduces the spectral measurement range and offers a way to observe the fast dynamic response. Based on that, a measurement resolution of 50 nm nanoparticle detection limit and a refractive index noise-limited resolution of 8.18 × 10−7 refractive index unit (RIU) are demonstrated. The dynamic phase transition of thermosensitive hydrogel is further investigated as a validation of its rapid detection capability. Integrated with an inherent microfluidic channel, the proposed microsensor provides a direct interaction between analytes and probe light with ultrasmall sample consumption down to 50 pl. It is expected to boost the detection of weak signals in microlasers and enlighten the development of optofluidic microsensors in exploring diverse biochemical processes.
APL PhotonicsPhysics and Astronomy-Atomic and Molecular Physics, and Optics
CiteScore
10.30
自引率
3.60%
发文量
107
审稿时长
19 weeks
期刊介绍:
APL Photonics is the new dedicated home for open access multidisciplinary research from and for the photonics community. The journal publishes fundamental and applied results that significantly advance the knowledge in photonics across physics, chemistry, biology and materials science.