电感耦合等离子体发射光谱法(ICP-OES)对永磁体生产链中的化学表征——超磁体样品中Nd、Pr、Fe和B的精确定量

IF 1.1 Q4 CHEMISTRY, ANALYTICAL Brazilian Journal of Analytical Chemistry Pub Date : 2022-05-17 DOI:10.30744/brjac.2179-3425.tn-108-2021
R. Papai, Karina Torre, G. Almeida, André da Silva, Thiago Nagasima, Eduardo Jabes, Célia Santos, F. Landgraf, M. Luz
{"title":"电感耦合等离子体发射光谱法(ICP-OES)对永磁体生产链中的化学表征——超磁体样品中Nd、Pr、Fe和B的精确定量","authors":"R. Papai, Karina Torre, G. Almeida, André da Silva, Thiago Nagasima, Eduardo Jabes, Célia Santos, F. Landgraf, M. Luz","doi":"10.30744/brjac.2179-3425.tn-108-2021","DOIUrl":null,"url":null,"abstract":"Super-magnets, materials whose strong magnetic activity is an attractive differential for the high-tech industry, may have their magnetic performance affected by small variations in their chemical composition. For example, the neodymium and praseodymium content can change the physicochemical properties of the permanent magnets. Aiming at a strict chemical quality control, this work developed an analytical method to quantify the major elements in the materials involved in the production process of didymium (the mixture of neodymium and praseodymium) super-magnets. The simultaneous determination of Nd (401.225 nm), Pr (414.311 nm), Fe (259.837 nm) and B (249.678 nm) in three different sample types (didymium oxide, metallic didymium and (Nd,Pr)-Fe-B alloy) was performed by sample dissolution in acidic media, followed by instrumental measurements using an Inductively Coupled Plasma Optical Emission Spectrometer. Linear calibration curves were obtained with high coefficient of determination (0.9983 ≤ R2 ≤ 0.9999) and with appropriate limits for determining these elements at the percentage level, reaching detection limits less than 0.07 cg g-1. The precision of the method was improved by weighing of the solutions during all the dilution steps and was evaluated by the coefficient of variation associated to instrumental precision (0.3 – 0.7%), method intermediate precision (1.9 – 3.1%) and also by the typical mass fraction provided as uncertainty (0.04 – 0.20 cg g-1), reaching the pressing need to distinguish the content of the rare earth elements in less than 1 cg g-1. The accuracy of the method was assessed by spiked and recovery test (96-104% for spikes equal to or greater than 0.50 cg g-1) and also by the use of different analytical methods, involving the participation of other laboratories, obtaining an acceptable degree of agreement (85 – 107%).","PeriodicalId":9115,"journal":{"name":"Brazilian Journal of Analytical Chemistry","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2022-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Chemical Characterization in the Production Chain of Permanent Magnets by Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES) – Precise Quantification of Nd, Pr, Fe and B in Super-Magnets Samples\",\"authors\":\"R. Papai, Karina Torre, G. Almeida, André da Silva, Thiago Nagasima, Eduardo Jabes, Célia Santos, F. Landgraf, M. Luz\",\"doi\":\"10.30744/brjac.2179-3425.tn-108-2021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Super-magnets, materials whose strong magnetic activity is an attractive differential for the high-tech industry, may have their magnetic performance affected by small variations in their chemical composition. For example, the neodymium and praseodymium content can change the physicochemical properties of the permanent magnets. Aiming at a strict chemical quality control, this work developed an analytical method to quantify the major elements in the materials involved in the production process of didymium (the mixture of neodymium and praseodymium) super-magnets. The simultaneous determination of Nd (401.225 nm), Pr (414.311 nm), Fe (259.837 nm) and B (249.678 nm) in three different sample types (didymium oxide, metallic didymium and (Nd,Pr)-Fe-B alloy) was performed by sample dissolution in acidic media, followed by instrumental measurements using an Inductively Coupled Plasma Optical Emission Spectrometer. Linear calibration curves were obtained with high coefficient of determination (0.9983 ≤ R2 ≤ 0.9999) and with appropriate limits for determining these elements at the percentage level, reaching detection limits less than 0.07 cg g-1. The precision of the method was improved by weighing of the solutions during all the dilution steps and was evaluated by the coefficient of variation associated to instrumental precision (0.3 – 0.7%), method intermediate precision (1.9 – 3.1%) and also by the typical mass fraction provided as uncertainty (0.04 – 0.20 cg g-1), reaching the pressing need to distinguish the content of the rare earth elements in less than 1 cg g-1. The accuracy of the method was assessed by spiked and recovery test (96-104% for spikes equal to or greater than 0.50 cg g-1) and also by the use of different analytical methods, involving the participation of other laboratories, obtaining an acceptable degree of agreement (85 – 107%).\",\"PeriodicalId\":9115,\"journal\":{\"name\":\"Brazilian Journal of Analytical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2022-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brazilian Journal of Analytical Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30744/brjac.2179-3425.tn-108-2021\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Analytical Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30744/brjac.2179-3425.tn-108-2021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 1

摘要

超级磁体是一种材料,其强磁活性对高科技行业来说是一个有吸引力的区别,其磁性能可能会受到其化学成分微小变化的影响。例如,钕和镨的含量可以改变永磁体的物理化学性质。为了严格控制化学质量,本工作开发了一种分析方法来量化钕(钕和镨的混合物)超级磁体生产过程中所涉及的材料中的主要元素。通过样品在酸性介质中的溶解,然后使用电感耦合等离子体光学发射光谱仪进行仪器测量,同时测定三种不同样品类型(氧化二钇、金属二钇和(Nd,Pr)-Fe-B合金)中的Nd(401.225 nm)、Pr(414.311 nm)、Fe(259.837 nm)和B(249.678 nm)。获得了线性校准曲线,测定系数高(0.9983≤R2≤0.9999),在百分比水平上测定这些元素的限值适当,检测限值小于0.07 cg g-1。通过在所有稀释步骤中对溶液进行称重,提高了该方法的精度,并通过与仪器精度(0.3–0.7%)、方法中间精度(1.9–3.1%)相关的变异系数以及作为不确定度提供的典型质量分数(0.04–0.20 cg g-1)进行了评估,达到了区分稀土元素含量小于1gg-1的迫切需要。该方法的准确性通过加标和回收率测试进行评估(加标量等于或大于0.50 cg g-1时为96-104%),还通过使用不同的分析方法进行评估,包括其他实验室的参与,获得可接受的一致性(85-107%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Chemical Characterization in the Production Chain of Permanent Magnets by Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES) – Precise Quantification of Nd, Pr, Fe and B in Super-Magnets Samples
Super-magnets, materials whose strong magnetic activity is an attractive differential for the high-tech industry, may have their magnetic performance affected by small variations in their chemical composition. For example, the neodymium and praseodymium content can change the physicochemical properties of the permanent magnets. Aiming at a strict chemical quality control, this work developed an analytical method to quantify the major elements in the materials involved in the production process of didymium (the mixture of neodymium and praseodymium) super-magnets. The simultaneous determination of Nd (401.225 nm), Pr (414.311 nm), Fe (259.837 nm) and B (249.678 nm) in three different sample types (didymium oxide, metallic didymium and (Nd,Pr)-Fe-B alloy) was performed by sample dissolution in acidic media, followed by instrumental measurements using an Inductively Coupled Plasma Optical Emission Spectrometer. Linear calibration curves were obtained with high coefficient of determination (0.9983 ≤ R2 ≤ 0.9999) and with appropriate limits for determining these elements at the percentage level, reaching detection limits less than 0.07 cg g-1. The precision of the method was improved by weighing of the solutions during all the dilution steps and was evaluated by the coefficient of variation associated to instrumental precision (0.3 – 0.7%), method intermediate precision (1.9 – 3.1%) and also by the typical mass fraction provided as uncertainty (0.04 – 0.20 cg g-1), reaching the pressing need to distinguish the content of the rare earth elements in less than 1 cg g-1. The accuracy of the method was assessed by spiked and recovery test (96-104% for spikes equal to or greater than 0.50 cg g-1) and also by the use of different analytical methods, involving the participation of other laboratories, obtaining an acceptable degree of agreement (85 – 107%).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.60
自引率
14.30%
发文量
46
期刊介绍: BrJAC is dedicated to the diffusion of significant and original knowledge in all branches of Analytical Chemistry, and is addressed to professionals involved in science, technology and innovation projects at universities, research centers and in industry.
期刊最新文献
Cork-Activated Carbon as a Sorptive Phase for Microextraction of Emerging Contaminants in Water Samples Development and Validation of an Analytical Method for the Determination of Fipronil and its Degradation Products in 28 Organic and Regular Honey Samples by GC-ECD Electrochemical Biosensors for the Detection of Viruses: Must-Have Products or Just Science for Publication? Mineral Composition of Rice, Carrots, and Chayote after Microwave-Assisted Decomposition using Diluted Nitric Acid Professor José Luis Capelo Martinez, a researcher who believes that science and technology have a direct and tangible impact on human well-being kindly granted BrJAC an interview
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1