{"title":"电机定子绕组故障对电机差模阻抗和模变换的影响","authors":"Fei Fan;Zhenyu Zhao;Huamin Jie;Quqin Sun;Pengfei Tu;Zhou Shu;Wensong Wang;Kye Yak See","doi":"10.23919/CJEE.2022.000022","DOIUrl":null,"url":null,"abstract":"Motor impedance and mode transformation have significant effects on the electromagnetic interference (EMI) generated in motor drive systems. Stator winding faults commonly cause motor failure; however, in their early stages, they may not affect the short-term operation of the motor. To date, EMI noise under the influence of premature stator winding faults has not been adequately studied, particularly the differential-mode (DM) noise due to the common-mode (CM)-to-DM transformation. This study investigates and quantifies the influence of stator winding faults on the motor DM impedance and mode transformation. First, the transmission line model of an induction motor is described based on the scattering (S) parameter measurements of each phase of the motor. It offers the flexibility to emulate different types of stator winding faults at specific locations and various severities, such that the impacts of the faults on the motor DM impedance can be easily estimated. Second, a test setup is proposed to quantify the CM-to-DM transformation due to the stator winding faults. The findings of this study reveal that even the early stages of stator winding faults can result in significant changes in the DM noise.","PeriodicalId":36428,"journal":{"name":"Chinese Journal of Electrical Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/7873788/9915414/09915503.pdf","citationCount":"0","resultStr":"{\"title\":\"Impact of Motor Stator Winding Faults on Motor Differential-mode Impedance and Mode Transformation\",\"authors\":\"Fei Fan;Zhenyu Zhao;Huamin Jie;Quqin Sun;Pengfei Tu;Zhou Shu;Wensong Wang;Kye Yak See\",\"doi\":\"10.23919/CJEE.2022.000022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Motor impedance and mode transformation have significant effects on the electromagnetic interference (EMI) generated in motor drive systems. Stator winding faults commonly cause motor failure; however, in their early stages, they may not affect the short-term operation of the motor. To date, EMI noise under the influence of premature stator winding faults has not been adequately studied, particularly the differential-mode (DM) noise due to the common-mode (CM)-to-DM transformation. This study investigates and quantifies the influence of stator winding faults on the motor DM impedance and mode transformation. First, the transmission line model of an induction motor is described based on the scattering (S) parameter measurements of each phase of the motor. It offers the flexibility to emulate different types of stator winding faults at specific locations and various severities, such that the impacts of the faults on the motor DM impedance can be easily estimated. Second, a test setup is proposed to quantify the CM-to-DM transformation due to the stator winding faults. The findings of this study reveal that even the early stages of stator winding faults can result in significant changes in the DM noise.\",\"PeriodicalId\":36428,\"journal\":{\"name\":\"Chinese Journal of Electrical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/iel7/7873788/9915414/09915503.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chinese Journal of Electrical Engineering\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/9915503/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Electrical Engineering","FirstCategoryId":"1087","ListUrlMain":"https://ieeexplore.ieee.org/document/9915503/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

电机阻抗和模态变换对电机驱动系统产生的电磁干扰有重要影响。定子绕组故障常引起电机故障;然而,在它们的早期阶段,它们可能不会影响电机的短期运行。迄今为止,尚未对定子绕组过早故障影响下的电磁干扰噪声进行充分研究,特别是由于共模(CM)到DM变换引起的差模(DM)噪声。研究定子绕组故障对电机DM阻抗和模态变换的影响。首先,基于对异步电动机各相位散射参数的测量,建立了异步电动机的传输线模型。它提供了在特定位置和不同严重程度上模拟不同类型的定子绕组故障的灵活性,从而可以轻松估计故障对电机DM阻抗的影响。其次,提出了一种量化定子绕组故障引起的cm - dm转换的测试装置。研究结果表明,即使在定子绕组故障的早期阶段,也会导致DM噪声的显著变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impact of Motor Stator Winding Faults on Motor Differential-mode Impedance and Mode Transformation
Motor impedance and mode transformation have significant effects on the electromagnetic interference (EMI) generated in motor drive systems. Stator winding faults commonly cause motor failure; however, in their early stages, they may not affect the short-term operation of the motor. To date, EMI noise under the influence of premature stator winding faults has not been adequately studied, particularly the differential-mode (DM) noise due to the common-mode (CM)-to-DM transformation. This study investigates and quantifies the influence of stator winding faults on the motor DM impedance and mode transformation. First, the transmission line model of an induction motor is described based on the scattering (S) parameter measurements of each phase of the motor. It offers the flexibility to emulate different types of stator winding faults at specific locations and various severities, such that the impacts of the faults on the motor DM impedance can be easily estimated. Second, a test setup is proposed to quantify the CM-to-DM transformation due to the stator winding faults. The findings of this study reveal that even the early stages of stator winding faults can result in significant changes in the DM noise.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Chinese Journal of Electrical Engineering
Chinese Journal of Electrical Engineering Energy-Energy Engineering and Power Technology
CiteScore
7.80
自引率
0.00%
发文量
621
审稿时长
12 weeks
期刊最新文献
Contents Front Cover Hybrid Modulation Strategy with Voltage Balancing Control for Four-Level Neutral-Point Clamped Converters Design-Oriented Transient Stability Assessment for Droop-Controlled Converter Considering Grid Voltage Phase-Angle Jump Dynamic Reconstruction of Total-Cross-Tied Photovoltaic Array Based on Arrays Using an Improved Dung Beetle Algorithm
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1