{"title":"基于性能的剪切连接扭斜板塑性设计和抗震性能评估","authors":"S. Song, Chonghou Zhang","doi":"10.1002/tal.1974","DOIUrl":null,"url":null,"abstract":"Twisted diagrid tube structures have become popular due to their significant lateral resistance and esthetic potential. However, the ductility and energy dissipation capacity of twisted diagrid structures are poor. This paper presents a seismic resilient fused structural system named the twisted diagrids with shear links (TDSL), and the performance‐based plastic design (PBPD) method is introduced for designing a 24‐story prototype structure. The numerical model of the TDSL prototype is established, then nonlinear static and dynamic analyses are conducted to evaluate the seismic behavior of the prototype. The results reveal that the TDSL system can significantly improve the post‐yield performance compared to the conventional twisted diagrid structure, and the performance objectives are achieved properly. Subsequently, incremental dynamic analyses are carried out to investigate the collapse fragility of the TDSL prototype, and the collapse risk of the prototype is assessed by FEMA P695. The results indicate that the TDSL prototype has satisfactory collapse‐resisting capacity under earthquakes. It is also found that corner columns can improve the seismic safety of the prototype against collapse. In general, the TDSL system is an appealing choice for twisted buildings in seismic regions.","PeriodicalId":49470,"journal":{"name":"Structural Design of Tall and Special Buildings","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2022-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Performance‐based plastic design and seismic performance evaluation of twisted diagrids with shear links\",\"authors\":\"S. Song, Chonghou Zhang\",\"doi\":\"10.1002/tal.1974\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Twisted diagrid tube structures have become popular due to their significant lateral resistance and esthetic potential. However, the ductility and energy dissipation capacity of twisted diagrid structures are poor. This paper presents a seismic resilient fused structural system named the twisted diagrids with shear links (TDSL), and the performance‐based plastic design (PBPD) method is introduced for designing a 24‐story prototype structure. The numerical model of the TDSL prototype is established, then nonlinear static and dynamic analyses are conducted to evaluate the seismic behavior of the prototype. The results reveal that the TDSL system can significantly improve the post‐yield performance compared to the conventional twisted diagrid structure, and the performance objectives are achieved properly. Subsequently, incremental dynamic analyses are carried out to investigate the collapse fragility of the TDSL prototype, and the collapse risk of the prototype is assessed by FEMA P695. The results indicate that the TDSL prototype has satisfactory collapse‐resisting capacity under earthquakes. It is also found that corner columns can improve the seismic safety of the prototype against collapse. In general, the TDSL system is an appealing choice for twisted buildings in seismic regions.\",\"PeriodicalId\":49470,\"journal\":{\"name\":\"Structural Design of Tall and Special Buildings\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2022-07-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structural Design of Tall and Special Buildings\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/tal.1974\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Design of Tall and Special Buildings","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/tal.1974","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Performance‐based plastic design and seismic performance evaluation of twisted diagrids with shear links
Twisted diagrid tube structures have become popular due to their significant lateral resistance and esthetic potential. However, the ductility and energy dissipation capacity of twisted diagrid structures are poor. This paper presents a seismic resilient fused structural system named the twisted diagrids with shear links (TDSL), and the performance‐based plastic design (PBPD) method is introduced for designing a 24‐story prototype structure. The numerical model of the TDSL prototype is established, then nonlinear static and dynamic analyses are conducted to evaluate the seismic behavior of the prototype. The results reveal that the TDSL system can significantly improve the post‐yield performance compared to the conventional twisted diagrid structure, and the performance objectives are achieved properly. Subsequently, incremental dynamic analyses are carried out to investigate the collapse fragility of the TDSL prototype, and the collapse risk of the prototype is assessed by FEMA P695. The results indicate that the TDSL prototype has satisfactory collapse‐resisting capacity under earthquakes. It is also found that corner columns can improve the seismic safety of the prototype against collapse. In general, the TDSL system is an appealing choice for twisted buildings in seismic regions.
期刊介绍:
The Structural Design of Tall and Special Buildings provides structural engineers and contractors with a detailed written presentation of innovative structural engineering and construction practices for tall and special buildings. It also presents applied research on new materials or analysis methods that can directly benefit structural engineers involved in the design of tall and special buildings. The editor''s policy is to maintain a reasonable balance between papers from design engineers and from research workers so that the Journal will be useful to both groups. The problems in this field and their solutions are international in character and require a knowledge of several traditional disciplines and the Journal will reflect this.
The main subject of the Journal is the structural design and construction of tall and special buildings. The basic definition of a tall building, in the context of the Journal audience, is a structure that is equal to or greater than 50 meters (165 feet) in height, or 14 stories or greater. A special building is one with unique architectural or structural characteristics.
However, manuscripts dealing with chimneys, water towers, silos, cooling towers, and pools will generally not be considered for review. The journal will present papers on new innovative structural systems, materials and methods of analysis.