用于术中甲状旁腺检测的手持式自动荧光成像系统

VideoEndocrinology Pub Date : 2023-03-22 eCollection Date: 2023-01-01 DOI:10.1089/ve.2022.0031
Nimesh V Nagururu, Khalid Mohamed Ali, Stefanie Seo, Yoseph Kim, Samantha A Wolfe, Jaepyeong Cha, Jonathon O Russell
{"title":"用于术中甲状旁腺检测的手持式自动荧光成像系统","authors":"Nimesh V Nagururu, Khalid Mohamed Ali, Stefanie Seo, Yoseph Kim, Samantha A Wolfe, Jaepyeong Cha, Jonathon O Russell","doi":"10.1089/ve.2022.0031","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Hypoparathyroidism and hypocalcemia are common complications after thyroid surgery. Parathyroids may be incidentally damaged or removed because they are difficult to distinguish from surrounding tissue. Intraoperative optical technologies such as near infrared autofluorescence (NIRAF) are becoming increasingly popular to help identify parathyroids during thyroid surgery. The objective of this video is to introduce a developing NIRAF device called hANDY-i and compare the device with existing Food and Drug Administration approved technology.</p><p><strong>Materials and methods: </strong>hANDY-i is developed by Optosurgical, LLC. The device consists of a coaxial 785 nm laser excitation module and coregistred red-green-blue and near-infrared cameras. Operation of the device and output from preliminary intraoperative use are shown.</p><p><strong>Results: </strong>hANDY-i performs well, producing intuitive side-by-side NIRAF and RGB images of the operating field. The device demonstrates high contrast between suspected parathyroid glands and surrounding tissue. Operating theater, overhead lamps, and surgical headlights can all be used with the device. The device is also shown to be effective in both <i>in vivo</i> and <i>ex vivo</i> applications.</p><p><strong>Conclusions: </strong>The prototype described advance NIRAF technology by reducing light sensitivity and improving output representation. In doing so, hANDY-i makes NIRAF more accessible and less obstructive to the surgical workflow.</p><p><strong>Sources of funding: </strong>This study was supported by the National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health under Award Number R43EB030874.</p><p><strong>Disclaimer: </strong>The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.Yoseph Kim is an employee of Optosurgical LLC. Jaepyeong Cha has ownership stake in Optosurgical LLC. For all other authors, no competing financial interests exist.Runtime of video: 7 mins 14 secs.</p>","PeriodicalId":75302,"journal":{"name":"VideoEndocrinology","volume":" ","pages":"9-10"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10739696/pdf/","citationCount":"0","resultStr":"{\"title\":\"Handheld Autofluorescence Imaging System for Intraoperative Parathyroid Detection.\",\"authors\":\"Nimesh V Nagururu, Khalid Mohamed Ali, Stefanie Seo, Yoseph Kim, Samantha A Wolfe, Jaepyeong Cha, Jonathon O Russell\",\"doi\":\"10.1089/ve.2022.0031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Hypoparathyroidism and hypocalcemia are common complications after thyroid surgery. Parathyroids may be incidentally damaged or removed because they are difficult to distinguish from surrounding tissue. Intraoperative optical technologies such as near infrared autofluorescence (NIRAF) are becoming increasingly popular to help identify parathyroids during thyroid surgery. The objective of this video is to introduce a developing NIRAF device called hANDY-i and compare the device with existing Food and Drug Administration approved technology.</p><p><strong>Materials and methods: </strong>hANDY-i is developed by Optosurgical, LLC. The device consists of a coaxial 785 nm laser excitation module and coregistred red-green-blue and near-infrared cameras. Operation of the device and output from preliminary intraoperative use are shown.</p><p><strong>Results: </strong>hANDY-i performs well, producing intuitive side-by-side NIRAF and RGB images of the operating field. The device demonstrates high contrast between suspected parathyroid glands and surrounding tissue. Operating theater, overhead lamps, and surgical headlights can all be used with the device. The device is also shown to be effective in both <i>in vivo</i> and <i>ex vivo</i> applications.</p><p><strong>Conclusions: </strong>The prototype described advance NIRAF technology by reducing light sensitivity and improving output representation. In doing so, hANDY-i makes NIRAF more accessible and less obstructive to the surgical workflow.</p><p><strong>Sources of funding: </strong>This study was supported by the National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health under Award Number R43EB030874.</p><p><strong>Disclaimer: </strong>The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.Yoseph Kim is an employee of Optosurgical LLC. Jaepyeong Cha has ownership stake in Optosurgical LLC. For all other authors, no competing financial interests exist.Runtime of video: 7 mins 14 secs.</p>\",\"PeriodicalId\":75302,\"journal\":{\"name\":\"VideoEndocrinology\",\"volume\":\" \",\"pages\":\"9-10\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10739696/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"VideoEndocrinology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1089/ve.2022.0031\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"VideoEndocrinology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/ve.2022.0031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

导言甲状旁腺功能减退症和低钙血症是甲状腺手术后常见的并发症。由于很难将甲状旁腺与周围组织区分开来,因此可能会意外损伤或切除甲状旁腺。近红外自动荧光(NIRAF)等术中光学技术在甲状腺手术中帮助识别甲状旁腺方面越来越受欢迎。本视频旨在介绍一种名为 hANDY-i 的开发中近红外自动荧光设备,并将该设备与现有的经食品药品管理局批准的技术进行比较。该设备由一个同轴 785 nm 激光激发模块、红-绿-蓝和近红外相机组成。结果显示:hANDY-i 性能良好,可生成直观的并排近红外和红绿蓝术野图像。该设备可显示可疑甲状旁腺与周围组织的高对比度。手术室、顶灯和手术头灯均可与该设备配合使用。该设备在体内和体外应用中也显示出良好的效果:结论:所描述的原型通过降低光敏感度和改善输出表现,推动了近红外荧光技术的发展。这样,hANDY-i 使近红外荧光技术更易于使用,并减少了对手术工作流程的阻碍:本研究得到了美国国立卫生研究院国家生物医学成像和生物工程研究所的支持,奖励号为 R43EB030874。免责声明:本文内容仅代表作者个人观点,不代表美国国立卫生研究院的官方观点。Yoseph Kim 是 Optosurgical LLC 的员工。Jaepyeong Cha持有Optosurgical LLC的股份。所有其他作者不存在经济利益冲突:7 分 14 秒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Handheld Autofluorescence Imaging System for Intraoperative Parathyroid Detection.

Introduction: Hypoparathyroidism and hypocalcemia are common complications after thyroid surgery. Parathyroids may be incidentally damaged or removed because they are difficult to distinguish from surrounding tissue. Intraoperative optical technologies such as near infrared autofluorescence (NIRAF) are becoming increasingly popular to help identify parathyroids during thyroid surgery. The objective of this video is to introduce a developing NIRAF device called hANDY-i and compare the device with existing Food and Drug Administration approved technology.

Materials and methods: hANDY-i is developed by Optosurgical, LLC. The device consists of a coaxial 785 nm laser excitation module and coregistred red-green-blue and near-infrared cameras. Operation of the device and output from preliminary intraoperative use are shown.

Results: hANDY-i performs well, producing intuitive side-by-side NIRAF and RGB images of the operating field. The device demonstrates high contrast between suspected parathyroid glands and surrounding tissue. Operating theater, overhead lamps, and surgical headlights can all be used with the device. The device is also shown to be effective in both in vivo and ex vivo applications.

Conclusions: The prototype described advance NIRAF technology by reducing light sensitivity and improving output representation. In doing so, hANDY-i makes NIRAF more accessible and less obstructive to the surgical workflow.

Sources of funding: This study was supported by the National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health under Award Number R43EB030874.

Disclaimer: The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.Yoseph Kim is an employee of Optosurgical LLC. Jaepyeong Cha has ownership stake in Optosurgical LLC. For all other authors, no competing financial interests exist.Runtime of video: 7 mins 14 secs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Correction to: Vocal Cord Monitoring by Flexible Fiberoptic Laryngoscopy During Thyroid Radiofrequency Ablation Videoendocrinology 2023 10(3): pp. 41–43; doi: 10.1089/ve.2023.0012 Vocal Cord Monitoring by Flexible Fiberoptic Laryngoscopy During Thyroid Radiofrequency Ablation. Advantages of TOETVA: A Remote Access Approach The Use and Abuse of Thyroid Hormone History of Thyroid Surgery in the Last Century
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1