DrSiddharth Singh, Pooja Saroj, C. Ghosh, P. Sinha
{"title":"WMO多布森相互比较活动期间印度多布森分光光度计D112和D036的校准","authors":"DrSiddharth Singh, Pooja Saroj, C. Ghosh, P. Sinha","doi":"10.54302/mausam.v74i1.5910","DOIUrl":null,"url":null,"abstract":"The present study summarizes the results of calibration of Indian Dobson Spectrophotometer No. D112 and D036 during Dobson inter-comparison campaigns, held at Irene, South Africa from 07 – 18 October, 2019 and at Hohenpeissenberg, Germany from 15.07.2020 to 30.07.2020 respectively. In both the international inter-comparison campaigns, European Regional Standard Dobson Spectrophotometer No. D064 had been used as the reference instrument. According to the results of the inter-comparison of Dobson spectrophotometer instrument no. D112 and no. D036 with Regional Standard Dobson Instrument (D064), these instruments are reliable and their measurements are accurate and appropriate for further analysis as their deviations have been found within the acceptable limits i.e. less than - 0.3% for D112 and less than 0.01 for D036 respectively after final calibration.","PeriodicalId":18363,"journal":{"name":"MAUSAM","volume":" ","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2022-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Calibration of Indian Dobson Spectrophotometer Nos. D112 and D036 during WMO Dobson Intercomparison Campaigns\",\"authors\":\"DrSiddharth Singh, Pooja Saroj, C. Ghosh, P. Sinha\",\"doi\":\"10.54302/mausam.v74i1.5910\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present study summarizes the results of calibration of Indian Dobson Spectrophotometer No. D112 and D036 during Dobson inter-comparison campaigns, held at Irene, South Africa from 07 – 18 October, 2019 and at Hohenpeissenberg, Germany from 15.07.2020 to 30.07.2020 respectively. In both the international inter-comparison campaigns, European Regional Standard Dobson Spectrophotometer No. D064 had been used as the reference instrument. According to the results of the inter-comparison of Dobson spectrophotometer instrument no. D112 and no. D036 with Regional Standard Dobson Instrument (D064), these instruments are reliable and their measurements are accurate and appropriate for further analysis as their deviations have been found within the acceptable limits i.e. less than - 0.3% for D112 and less than 0.01 for D036 respectively after final calibration.\",\"PeriodicalId\":18363,\"journal\":{\"name\":\"MAUSAM\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2022-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"MAUSAM\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.54302/mausam.v74i1.5910\",\"RegionNum\":4,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"METEOROLOGY & ATMOSPHERIC SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"MAUSAM","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.54302/mausam.v74i1.5910","RegionNum":4,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"METEOROLOGY & ATMOSPHERIC SCIENCES","Score":null,"Total":0}
Calibration of Indian Dobson Spectrophotometer Nos. D112 and D036 during WMO Dobson Intercomparison Campaigns
The present study summarizes the results of calibration of Indian Dobson Spectrophotometer No. D112 and D036 during Dobson inter-comparison campaigns, held at Irene, South Africa from 07 – 18 October, 2019 and at Hohenpeissenberg, Germany from 15.07.2020 to 30.07.2020 respectively. In both the international inter-comparison campaigns, European Regional Standard Dobson Spectrophotometer No. D064 had been used as the reference instrument. According to the results of the inter-comparison of Dobson spectrophotometer instrument no. D112 and no. D036 with Regional Standard Dobson Instrument (D064), these instruments are reliable and their measurements are accurate and appropriate for further analysis as their deviations have been found within the acceptable limits i.e. less than - 0.3% for D112 and less than 0.01 for D036 respectively after final calibration.
期刊介绍:
MAUSAM (Formerly Indian Journal of Meteorology, Hydrology & Geophysics), established in January 1950, is the quarterly research
journal brought out by the India Meteorological Department (IMD). MAUSAM is a medium for publication of original scientific
research work. MAUSAM is a premier scientific research journal published in this part of the world in the fields of Meteorology,
Hydrology & Geophysics. The four issues appear in January, April, July & October.