采血管中抗凝血剂对混合精液训练样本酸性磷酸酶检测的抑制作用

J. Lau, Jorge Frasca, M.L. Nicholson, N. Laurin
{"title":"采血管中抗凝血剂对混合精液训练样本酸性磷酸酶检测的抑制作用","authors":"J. Lau, Jorge Frasca, M.L. Nicholson, N. Laurin","doi":"10.1080/00085030.2020.1753277","DOIUrl":null,"url":null,"abstract":"Abstract Acid phosphatase detection using fast blue or fast black reagent is routinely performed at the RCMP National Forensic Laboratory Services as a presumptive test for semen. In training exercises, samples consisting of semen mixed with blood were reported to yield negative results with the fast black reagent. To determine the cause of the inhibition, mixed semen-blood stains were prepared using different blood sources, anti-coagulants, and layering techniques, before being tested with the fast blue or the fast black reagent. The anti-coagulant sodium fluoride (NaF) was shown to cause false negative results with the fast black reagent and to impair detection when using the fast blue reagent while no inhibition was observed when dipotassium EDTA (K2 EDTA) was used as anti-coagulant. Four different toothpastes containing fluoride were also tested for potential inhibition of semen detection. Inhibition was observed when semen was mixed with three of the undiluted toothpastes but not with diluted toothpastes (1 in 20 in water). These findings highlight the importance of using appropriate blood sources when preparing mixed semen-blood stains for the purpose of training and proficiency testing in a forensic laboratory. However, forensic casework samples are not expected to contain NaF at the inhibiting levels.","PeriodicalId":44383,"journal":{"name":"Canadian Society of Forensic Science Journal","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2020-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00085030.2020.1753277","citationCount":"0","resultStr":"{\"title\":\"Inhibition of acid phosphatase detection in mixed semen-blood training samples by anti-coagulants present in blood collection tubes\",\"authors\":\"J. Lau, Jorge Frasca, M.L. Nicholson, N. Laurin\",\"doi\":\"10.1080/00085030.2020.1753277\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Acid phosphatase detection using fast blue or fast black reagent is routinely performed at the RCMP National Forensic Laboratory Services as a presumptive test for semen. In training exercises, samples consisting of semen mixed with blood were reported to yield negative results with the fast black reagent. To determine the cause of the inhibition, mixed semen-blood stains were prepared using different blood sources, anti-coagulants, and layering techniques, before being tested with the fast blue or the fast black reagent. The anti-coagulant sodium fluoride (NaF) was shown to cause false negative results with the fast black reagent and to impair detection when using the fast blue reagent while no inhibition was observed when dipotassium EDTA (K2 EDTA) was used as anti-coagulant. Four different toothpastes containing fluoride were also tested for potential inhibition of semen detection. Inhibition was observed when semen was mixed with three of the undiluted toothpastes but not with diluted toothpastes (1 in 20 in water). These findings highlight the importance of using appropriate blood sources when preparing mixed semen-blood stains for the purpose of training and proficiency testing in a forensic laboratory. However, forensic casework samples are not expected to contain NaF at the inhibiting levels.\",\"PeriodicalId\":44383,\"journal\":{\"name\":\"Canadian Society of Forensic Science Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2020-04-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/00085030.2020.1753277\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian Society of Forensic Science Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/00085030.2020.1753277\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, LEGAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Society of Forensic Science Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00085030.2020.1753277","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
引用次数: 0

摘要

摘要在加拿大皇家骑警国家法医实验室服务中心,使用快速蓝或快速黑试剂进行酸性磷酸酶检测是精液的推定检测。据报道,在训练练习中,由精液和血液混合而成的样本在使用快速黑色试剂时产生了阴性结果。为了确定抑制的原因,在用快速蓝或快速黑试剂进行测试之前,使用不同的血源、抗凝血剂和分层技术制备混合精液血迹。抗凝剂氟化钠(NaF)在使用快黑试剂时会导致假阴性结果,并且在使用快蓝试剂时会损害检测,而当使用EDTA二钾(K2-EDTA)作为抗凝剂时没有观察到抑制作用。还测试了四种不同的含氟牙膏对精液检测的潜在抑制作用。当精液与三种未稀释的牙膏混合,但不与稀释的牙膏(水中1/20)混合时,观察到抑制作用。这些发现强调了在法医实验室进行培训和能力测试时,在制备混合精液血迹时使用适当的血液来源的重要性。然而,法医案例样本预计不会含有抑制水平的氟化钠。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Inhibition of acid phosphatase detection in mixed semen-blood training samples by anti-coagulants present in blood collection tubes
Abstract Acid phosphatase detection using fast blue or fast black reagent is routinely performed at the RCMP National Forensic Laboratory Services as a presumptive test for semen. In training exercises, samples consisting of semen mixed with blood were reported to yield negative results with the fast black reagent. To determine the cause of the inhibition, mixed semen-blood stains were prepared using different blood sources, anti-coagulants, and layering techniques, before being tested with the fast blue or the fast black reagent. The anti-coagulant sodium fluoride (NaF) was shown to cause false negative results with the fast black reagent and to impair detection when using the fast blue reagent while no inhibition was observed when dipotassium EDTA (K2 EDTA) was used as anti-coagulant. Four different toothpastes containing fluoride were also tested for potential inhibition of semen detection. Inhibition was observed when semen was mixed with three of the undiluted toothpastes but not with diluted toothpastes (1 in 20 in water). These findings highlight the importance of using appropriate blood sources when preparing mixed semen-blood stains for the purpose of training and proficiency testing in a forensic laboratory. However, forensic casework samples are not expected to contain NaF at the inhibiting levels.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.00
自引率
0.00%
发文量
21
期刊最新文献
The effect of flat and undulating terrain on the post-feeding dispersal distance from carcasses of blow fly larvae (Calliphoridae: Lucilia illustris ) Effects of relative humidity on egg hatching success of blow flies (Diptera: Calliphoridae) Age estimation using the Demirjian method in third molars on cone beam computed tomography images Experimental use of pig cadavers to locate homicide victim in a large river The effect of bait age and season on trap catch of blow fly species composition (Diptera: Calliphoridae) in a suburban habitat
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1