基于高灵敏度正电子发射断层扫描/计算机断层扫描患者规范的18F-氟脱氧葡萄糖采集时间和注射剂量的优化

IF 0.6 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING World Journal of Nuclear Medicine Pub Date : 2023-09-06 DOI:10.1055/s-0043-1771284
M. Al-Fatlawi, Farideh Pak, Saeed Farzanefar, Yalda Salehi, Abbas Monsef, P. Sheikhzadeh
{"title":"基于高灵敏度正电子发射断层扫描/计算机断层扫描患者规范的18F-氟脱氧葡萄糖采集时间和注射剂量的优化","authors":"M. Al-Fatlawi, Farideh Pak, Saeed Farzanefar, Yalda Salehi, Abbas Monsef, P. Sheikhzadeh","doi":"10.1055/s-0043-1771284","DOIUrl":null,"url":null,"abstract":"Abstract: Background  This study was aimed to optimize the fluorodeoxyglucose (FDG)-administered dose and scan time based on patient specifications using a highly sensitive five-ring bismuth germanium oxide (BGO)-based positron emission tomography/computed tomography (PET/CT) scanner (Discovery IQ). Methods  We retrospectively analyzed 101 whole-body 18 F-FDG PET/CT images. Patient data were reconstructed using ordered subset expectation maximization with resolution recovery algorithms (OSEM + SharpIR). Signal-to-noise ratio (SNR) was calculated for each patient, standardized to SNR norm , and plotted against three body index parameters (weight, body mass index, and lean body mass). Two professional physicians blindly examined image quality at different patient time per bed positions to determine the minimum acceptable quality. To select images of acceptable quality, the noise index parameter was also measured. A new dose-time product (DTP) was established for each patient, and a predicted injected dose was assumed. Results  We found an almost linear association between patient weight and normalized SNR, and patient weight had the highest R 2 in the fitting. The redesigned DTP can reduce results by approximately 74 and 38% compared with ordinary DTP for 80- and 160-s scan durations. The new dose regimen formula was found to be DTP =  c/t × m 1.24 , where m is the patient weight, t is the scan time per bed position, and c is 1.8 and 4.3 for acceptable and higher confidence states, respectively, in Discovery IQ PET/CT. Conclusion  Patient weight is the best clinical parameter for the implementation of 18 F-FDG PET/CT image quality assessment. A new dose-time regimen based on body weight was proposed for use in highly sensitive five-ring BGO PET-CT scanners to significantly reduce the injection dose and scan times while maintaining sufficient image quality for diagnosis.","PeriodicalId":23742,"journal":{"name":"World Journal of Nuclear Medicine","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2023-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization of the Acquisition Time and Injected Dose of 18 F-Fluorodeoxyglucose Based on Patient Specifications for High-Sensitive Positron Emission Tomography/Computed Tomography Scanner\",\"authors\":\"M. Al-Fatlawi, Farideh Pak, Saeed Farzanefar, Yalda Salehi, Abbas Monsef, P. Sheikhzadeh\",\"doi\":\"10.1055/s-0043-1771284\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract: Background  This study was aimed to optimize the fluorodeoxyglucose (FDG)-administered dose and scan time based on patient specifications using a highly sensitive five-ring bismuth germanium oxide (BGO)-based positron emission tomography/computed tomography (PET/CT) scanner (Discovery IQ). Methods  We retrospectively analyzed 101 whole-body 18 F-FDG PET/CT images. Patient data were reconstructed using ordered subset expectation maximization with resolution recovery algorithms (OSEM + SharpIR). Signal-to-noise ratio (SNR) was calculated for each patient, standardized to SNR norm , and plotted against three body index parameters (weight, body mass index, and lean body mass). Two professional physicians blindly examined image quality at different patient time per bed positions to determine the minimum acceptable quality. To select images of acceptable quality, the noise index parameter was also measured. A new dose-time product (DTP) was established for each patient, and a predicted injected dose was assumed. Results  We found an almost linear association between patient weight and normalized SNR, and patient weight had the highest R 2 in the fitting. The redesigned DTP can reduce results by approximately 74 and 38% compared with ordinary DTP for 80- and 160-s scan durations. The new dose regimen formula was found to be DTP =  c/t × m 1.24 , where m is the patient weight, t is the scan time per bed position, and c is 1.8 and 4.3 for acceptable and higher confidence states, respectively, in Discovery IQ PET/CT. Conclusion  Patient weight is the best clinical parameter for the implementation of 18 F-FDG PET/CT image quality assessment. A new dose-time regimen based on body weight was proposed for use in highly sensitive five-ring BGO PET-CT scanners to significantly reduce the injection dose and scan times while maintaining sufficient image quality for diagnosis.\",\"PeriodicalId\":23742,\"journal\":{\"name\":\"World Journal of Nuclear Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"World Journal of Nuclear Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0043-1771284\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1771284","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

摘要:背景 本研究旨在使用基于高灵敏度五环氧化铋锗(BGO)的正电子发射断层扫描/计算机断层扫描(PET/CT)扫描仪(Discovery IQ),根据患者规格优化氟脱氧葡萄糖(FDG)的给药剂量和扫描时间。方法 我们回顾性分析了101例全身18F-FDG PET/CT图像。使用有序子集期望最大化和分辨率恢复算法(OSEM+SharpIR)重建患者数据。计算每个患者的信噪比(SNR),标准化为SNR标准,并根据三个身体指数参数(体重、体重指数和瘦体重)绘制。两位专业医生盲目地检查了每个床位不同患者时间的图像质量,以确定可接受的最低质量。为了选择质量可接受的图像,还测量了噪声指数参数。为每位患者建立新的剂量-时间乘积(DTP),并假设预测的注射剂量。后果 我们发现患者体重和归一化SNR之间几乎呈线性关系,并且患者体重在拟合中具有最高的R2。与普通DTP相比,在80秒和160秒的扫描持续时间内,重新设计的DTP可以将结果减少约74%和38%。新的给药方案是DTP =  c/t × m 1.24,其中m是患者体重,t是每个床位的扫描时间,对于Discovery IQ PET/CT中的可接受和较高置信度状态,c分别为1.8和4.3。结论 患者体重是实施18F-FDG PET/CT图像质量评估的最佳临床参数。提出了一种基于体重的新剂量-时间方案,用于高灵敏度的五环BGO PET-CT扫描仪,以显著减少注射剂量和扫描时间,同时保持足够的诊断图像质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimization of the Acquisition Time and Injected Dose of 18 F-Fluorodeoxyglucose Based on Patient Specifications for High-Sensitive Positron Emission Tomography/Computed Tomography Scanner
Abstract: Background  This study was aimed to optimize the fluorodeoxyglucose (FDG)-administered dose and scan time based on patient specifications using a highly sensitive five-ring bismuth germanium oxide (BGO)-based positron emission tomography/computed tomography (PET/CT) scanner (Discovery IQ). Methods  We retrospectively analyzed 101 whole-body 18 F-FDG PET/CT images. Patient data were reconstructed using ordered subset expectation maximization with resolution recovery algorithms (OSEM + SharpIR). Signal-to-noise ratio (SNR) was calculated for each patient, standardized to SNR norm , and plotted against three body index parameters (weight, body mass index, and lean body mass). Two professional physicians blindly examined image quality at different patient time per bed positions to determine the minimum acceptable quality. To select images of acceptable quality, the noise index parameter was also measured. A new dose-time product (DTP) was established for each patient, and a predicted injected dose was assumed. Results  We found an almost linear association between patient weight and normalized SNR, and patient weight had the highest R 2 in the fitting. The redesigned DTP can reduce results by approximately 74 and 38% compared with ordinary DTP for 80- and 160-s scan durations. The new dose regimen formula was found to be DTP =  c/t × m 1.24 , where m is the patient weight, t is the scan time per bed position, and c is 1.8 and 4.3 for acceptable and higher confidence states, respectively, in Discovery IQ PET/CT. Conclusion  Patient weight is the best clinical parameter for the implementation of 18 F-FDG PET/CT image quality assessment. A new dose-time regimen based on body weight was proposed for use in highly sensitive five-ring BGO PET-CT scanners to significantly reduce the injection dose and scan times while maintaining sufficient image quality for diagnosis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
World Journal of Nuclear Medicine
World Journal of Nuclear Medicine RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
自引率
16.70%
发文量
118
审稿时长
48 weeks
期刊最新文献
Portal Venous Tumor Thrombosis and Visceral Organ Metastasis without Skeletal Involvement in mCRPC: Adverse Prognostic Indicators on Dual Tracer PET/CT and Clinical Outcome after 177Lu-PSMA-617 PRLT and Cabazitaxel Therapy Aggressive Metastatic Insulinoma in a Patient of Diabetes Mellitus with Documentation on Dual-Tracer PET-CT ([68Ga]Ga-DOTATATE and [18F]FDG): Clinical Benefits with Combined Chemo-PRRT Approach Trifecta of Tumors: Simultaneous Detection of Three Primary Malignancies by Different Radiotracers of Nuclear Medicine Extensive Multiorgan and Neurological Involvement on F-18 FDG PET-CT in a Case of Rosai-Dorfman Disease Role of Textural Analysis Parameters Derived from FDG PET/CT in Diagnosing Cardiac Sarcoidosis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1