{"title":"一种新型的可操纵导管弯曲拟线性粘弹性模型","authors":"Jajun Ryu, Jung-Hwa Ahn, Hwa-Young Kim","doi":"10.1115/1.4063215","DOIUrl":null,"url":null,"abstract":"\n The present study proposes a novel model that establishes the relationship between the bending moment and the curvature of a steerable catheter. The catheters exhibit a nonlinear viscoelastic tendency, so the moment-curvature relationship is modeled as a bending of a quasilinear viscoelastic (QLV) cantilever beam. Stress relaxation tests with multiple magnitudes are performed on a catheter, and the parameter tuning is carried out with the test results to find out the coefficients of the model. The form of the instantaneous moment response, which is an important term within the QLV equation, is selected as a logarithmic form by analyzing the test results. This differentiates the accuracy of the model from using the commonly used exponential form. The performance of the logarithmic QLV model is compared to the conventional models by checking the curvature range each model can cover with a certain accuracy. The covering range for elastic, linear viscoelastic, and exponential QLV models are 22.1%, 64.4%, and 55.5%, respectively, whereas the covering range of the logarithmic QLV model is 100%.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":" ","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2023-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Novel Quasilinear Viscoelastic Model of the Bending of a Steerable Catheter\",\"authors\":\"Jajun Ryu, Jung-Hwa Ahn, Hwa-Young Kim\",\"doi\":\"10.1115/1.4063215\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n The present study proposes a novel model that establishes the relationship between the bending moment and the curvature of a steerable catheter. The catheters exhibit a nonlinear viscoelastic tendency, so the moment-curvature relationship is modeled as a bending of a quasilinear viscoelastic (QLV) cantilever beam. Stress relaxation tests with multiple magnitudes are performed on a catheter, and the parameter tuning is carried out with the test results to find out the coefficients of the model. The form of the instantaneous moment response, which is an important term within the QLV equation, is selected as a logarithmic form by analyzing the test results. This differentiates the accuracy of the model from using the commonly used exponential form. The performance of the logarithmic QLV model is compared to the conventional models by checking the curvature range each model can cover with a certain accuracy. The covering range for elastic, linear viscoelastic, and exponential QLV models are 22.1%, 64.4%, and 55.5%, respectively, whereas the covering range of the logarithmic QLV model is 100%.\",\"PeriodicalId\":49305,\"journal\":{\"name\":\"Journal of Medical Devices-Transactions of the Asme\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-08-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4063215\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4063215","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
A Novel Quasilinear Viscoelastic Model of the Bending of a Steerable Catheter
The present study proposes a novel model that establishes the relationship between the bending moment and the curvature of a steerable catheter. The catheters exhibit a nonlinear viscoelastic tendency, so the moment-curvature relationship is modeled as a bending of a quasilinear viscoelastic (QLV) cantilever beam. Stress relaxation tests with multiple magnitudes are performed on a catheter, and the parameter tuning is carried out with the test results to find out the coefficients of the model. The form of the instantaneous moment response, which is an important term within the QLV equation, is selected as a logarithmic form by analyzing the test results. This differentiates the accuracy of the model from using the commonly used exponential form. The performance of the logarithmic QLV model is compared to the conventional models by checking the curvature range each model can cover with a certain accuracy. The covering range for elastic, linear viscoelastic, and exponential QLV models are 22.1%, 64.4%, and 55.5%, respectively, whereas the covering range of the logarithmic QLV model is 100%.
期刊介绍:
The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.