ATS系统(自动传输开关)的应用,以控制、监控和维护为基础(事物互联网)

Syahrul Pambudi, V. Prasetia, Saepul Rahmat
{"title":"ATS系统(自动传输开关)的应用,以控制、监控和维护为基础(事物互联网)","authors":"Syahrul Pambudi, V. Prasetia, Saepul Rahmat","doi":"10.35970/infotekmesin.v14i2.1853","DOIUrl":null,"url":null,"abstract":"The need for electricity is increasing along with population growth. The main electricity supply (PLN) is not always continuous in its distribution, so alternative power is needed, namely generators. The ATS (Automatic Transfer Switch) system can transfer the voltage source to the load. The ATS system is equipped with IOT in the form of a Blynk application on Android which functions as a controller and can send ATS damage notifications. This research was conducted to meet the electricity needs. Users can monitor, control and maintain the ATS system in the event of a breakdown. The method in this study uses a quantitative method, namely data collection by testing the ATS system and testing the IOT Blynk application function as a notification of damage to the ATS system. The result of transferring the PLN voltage to the generator is only 7 seconds and 3 seconds vice versa. There was damage to the lamp cable 1 time, the relay 1 time, and the fan cable 2 times. The results of measuring the current and voltage of the PLN source: lamp load 0.02A, 3.4V; fan 0.04A, 3.5V; AC motor 0.04A, 4V. Generator current and voltage measurements are as follows: lamp load 0.02 A, 9.1V; 0.03A, 9V fan; AC motor 0.05A, 4.5V. \n ","PeriodicalId":33598,"journal":{"name":"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Penerapan Sistem ATS (Automatic Transfer Switch) sebagai Pengendalian, Pemantauan, dan Perawatan Berbasis IoT (Internet of Things)\",\"authors\":\"Syahrul Pambudi, V. Prasetia, Saepul Rahmat\",\"doi\":\"10.35970/infotekmesin.v14i2.1853\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The need for electricity is increasing along with population growth. The main electricity supply (PLN) is not always continuous in its distribution, so alternative power is needed, namely generators. The ATS (Automatic Transfer Switch) system can transfer the voltage source to the load. The ATS system is equipped with IOT in the form of a Blynk application on Android which functions as a controller and can send ATS damage notifications. This research was conducted to meet the electricity needs. Users can monitor, control and maintain the ATS system in the event of a breakdown. The method in this study uses a quantitative method, namely data collection by testing the ATS system and testing the IOT Blynk application function as a notification of damage to the ATS system. The result of transferring the PLN voltage to the generator is only 7 seconds and 3 seconds vice versa. There was damage to the lamp cable 1 time, the relay 1 time, and the fan cable 2 times. The results of measuring the current and voltage of the PLN source: lamp load 0.02A, 3.4V; fan 0.04A, 3.5V; AC motor 0.04A, 4V. Generator current and voltage measurements are as follows: lamp load 0.02 A, 9.1V; 0.03A, 9V fan; AC motor 0.05A, 4.5V. \\n \",\"PeriodicalId\":33598,\"journal\":{\"name\":\"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35970/infotekmesin.v14i2.1853\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35970/infotekmesin.v14i2.1853","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

随着人口的增长,对电力的需求也在增加。主电源(PLN)在其分布中并不总是连续的,因此需要替代电源,即发电机。ATS(自动转换开关)系统可以将电压源转换为负载。ATS系统以Blynk应用程序的形式配备物联网,作为控制器,可以发送ATS损坏通知。这项研究是为了满足电力需求。用户可以在发生故障时监视、控制和维护ATS系统。本研究方法采用定量方法,即通过测试ATS系统收集数据,测试IOT Blynk应用功能作为ATS系统损坏通知。将PLN电压传输到发电机的结果仅为7秒,反之则为3秒。灯电缆损坏1次,继电器损坏1次,风扇电缆损坏2次。测量PLN源电流和电压的结果:灯负载0.02A, 3.4V;风扇0.04A, 3.5V;交流电机0.04A, 4V。发电机电流和电压测量如下:灯负载0.02 A, 9.1V;0.03A, 9V风扇;交流电机0.05A, 4.5V。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Penerapan Sistem ATS (Automatic Transfer Switch) sebagai Pengendalian, Pemantauan, dan Perawatan Berbasis IoT (Internet of Things)
The need for electricity is increasing along with population growth. The main electricity supply (PLN) is not always continuous in its distribution, so alternative power is needed, namely generators. The ATS (Automatic Transfer Switch) system can transfer the voltage source to the load. The ATS system is equipped with IOT in the form of a Blynk application on Android which functions as a controller and can send ATS damage notifications. This research was conducted to meet the electricity needs. Users can monitor, control and maintain the ATS system in the event of a breakdown. The method in this study uses a quantitative method, namely data collection by testing the ATS system and testing the IOT Blynk application function as a notification of damage to the ATS system. The result of transferring the PLN voltage to the generator is only 7 seconds and 3 seconds vice versa. There was damage to the lamp cable 1 time, the relay 1 time, and the fan cable 2 times. The results of measuring the current and voltage of the PLN source: lamp load 0.02A, 3.4V; fan 0.04A, 3.5V; AC motor 0.04A, 4V. Generator current and voltage measurements are as follows: lamp load 0.02 A, 9.1V; 0.03A, 9V fan; AC motor 0.05A, 4.5V.  
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
30
审稿时长
12 weeks
期刊最新文献
Perhitungan Pengendalian Persediaan Fast Moving Spare Part Dengan Metode Min-Max Stock Rancang Bangun Sistem Pengisian Otomatis Merica Bubuk Berbasis Kontroler Arduino Nano Klasifikasi Opini Publik di Twitter Terhadap Bakal Calon Presiden Indonesia Tahun 2024 Menggunakan LSTM Secara Realtime Berbasis Website Optimalisasi Labview Sebagai Kendali dan Monitoring Arus Tegangan pada Modul Solar Cell Menggunakan Jaringan Lokal Analisis Kekuatan Tarik dan Regangan Filamen Carbon Fiber Hasil 3D Print dengan Variasi Fill Density
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1