{"title":"超长自动扶梯安全吗?香港朗豪坊自动梯事件的教训","authors":"A. Ngan, K. Siu","doi":"10.33430/V28N1THIE-2019-0029","DOIUrl":null,"url":null,"abstract":"Super-long escalators that are increasingly used in mega-cities take up a large number of passengers, and so their risk of sudden failure draws serious attention. As a case study, on 25 March 2017, an escalator with a 21 m elevation in Hong Kong’s Langham Place had its main drive chain suddenly snapped by metal fatigue, causing the escalator to reverse at an accelerating speed. A number of passengers were injured. In this paper, two issues will be discussed: (1) whether metal fatigue of the main drive chain can be detected with conventional protocols, and (2) what safety factor is needed to prevent metal fatigue. Analysis shows that initial fatigue cracks in escalator drive chains may not be easily detected with the commonly adopted maintenance protocol. Also, the time window from the emergence of clear signs of fatigue failure to the sudden snapping of the drive chain may be as short as weeks or even days, versus the common safety inspection intervals of six months. The safety factor to prevent metal fatigue of the drive chain should be at least 7, whereas lower values are currently allowed. It is suggested that the government should review the legal requirements to meet the recommended value.","PeriodicalId":35587,"journal":{"name":"Transactions Hong Kong Institution of Engineers","volume":"28 1","pages":"49-57"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Are super-long escalators safe? Lessons learned from the Langham Place escalator incident in Hong Kong\",\"authors\":\"A. Ngan, K. Siu\",\"doi\":\"10.33430/V28N1THIE-2019-0029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Super-long escalators that are increasingly used in mega-cities take up a large number of passengers, and so their risk of sudden failure draws serious attention. As a case study, on 25 March 2017, an escalator with a 21 m elevation in Hong Kong’s Langham Place had its main drive chain suddenly snapped by metal fatigue, causing the escalator to reverse at an accelerating speed. A number of passengers were injured. In this paper, two issues will be discussed: (1) whether metal fatigue of the main drive chain can be detected with conventional protocols, and (2) what safety factor is needed to prevent metal fatigue. Analysis shows that initial fatigue cracks in escalator drive chains may not be easily detected with the commonly adopted maintenance protocol. Also, the time window from the emergence of clear signs of fatigue failure to the sudden snapping of the drive chain may be as short as weeks or even days, versus the common safety inspection intervals of six months. The safety factor to prevent metal fatigue of the drive chain should be at least 7, whereas lower values are currently allowed. It is suggested that the government should review the legal requirements to meet the recommended value.\",\"PeriodicalId\":35587,\"journal\":{\"name\":\"Transactions Hong Kong Institution of Engineers\",\"volume\":\"28 1\",\"pages\":\"49-57\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions Hong Kong Institution of Engineers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33430/V28N1THIE-2019-0029\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions Hong Kong Institution of Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33430/V28N1THIE-2019-0029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
Are super-long escalators safe? Lessons learned from the Langham Place escalator incident in Hong Kong
Super-long escalators that are increasingly used in mega-cities take up a large number of passengers, and so their risk of sudden failure draws serious attention. As a case study, on 25 March 2017, an escalator with a 21 m elevation in Hong Kong’s Langham Place had its main drive chain suddenly snapped by metal fatigue, causing the escalator to reverse at an accelerating speed. A number of passengers were injured. In this paper, two issues will be discussed: (1) whether metal fatigue of the main drive chain can be detected with conventional protocols, and (2) what safety factor is needed to prevent metal fatigue. Analysis shows that initial fatigue cracks in escalator drive chains may not be easily detected with the commonly adopted maintenance protocol. Also, the time window from the emergence of clear signs of fatigue failure to the sudden snapping of the drive chain may be as short as weeks or even days, versus the common safety inspection intervals of six months. The safety factor to prevent metal fatigue of the drive chain should be at least 7, whereas lower values are currently allowed. It is suggested that the government should review the legal requirements to meet the recommended value.