结构钢筋混凝土墙、楼板和重力框架相互作用引起的系统超强度因子:解析公式

R. E. Sedgh, R. Dhakal, C. Lee, A. Carr
{"title":"结构钢筋混凝土墙、楼板和重力框架相互作用引起的系统超强度因子:解析公式","authors":"R. E. Sedgh, R. Dhakal, C. Lee, A. Carr","doi":"10.5459/bnzsee.55.3.138-154","DOIUrl":null,"url":null,"abstract":"In multi-storey structural wall buildings, the structural walls are required to resist additional shear force due to their interactions with the floors and gravity-resisting system, which is not fully catered for in current seismic design provisions and assessment guidelines. This paper scrutinizes the mechanics of the interaction between structural reinforced concrete (RC) structural walls, floors and gravity frames in multi-storey RC structural wall buildings during elastic and nonlinear response phases. It also investigates the implications of this interaction on design of multi-story RC wall buildings. Generic expressions are derived to predict the drift and rotation profiles of multi-storey RC wall buildings. Then, a simple hand calculation method is developed to estimate the system (moment) overstrength of multi-storey RC wall buildings due to system (wall-floor-frames) interaction. The proposed method is applied to a prototype building with different slab dimensions and stiffness, and verified by comparing with the system overstrength factor obtained using finite element analysis. The simplified method estimates, and the nonlinear finite element analyses results agree, that a system overstrength factor of 1.7 can be used to account for the 3D interaction between the structural walls, floors and gravity frames in design and assessment of typical ductile RC wall buildings.","PeriodicalId":46396,"journal":{"name":"Bulletin of the New Zealand Society for Earthquake Engineering","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"System overstrength factor induced by interaction between structural reinforced concrete walls, floors and gravity frames: Analytical formulation\",\"authors\":\"R. E. Sedgh, R. Dhakal, C. Lee, A. Carr\",\"doi\":\"10.5459/bnzsee.55.3.138-154\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In multi-storey structural wall buildings, the structural walls are required to resist additional shear force due to their interactions with the floors and gravity-resisting system, which is not fully catered for in current seismic design provisions and assessment guidelines. This paper scrutinizes the mechanics of the interaction between structural reinforced concrete (RC) structural walls, floors and gravity frames in multi-storey RC structural wall buildings during elastic and nonlinear response phases. It also investigates the implications of this interaction on design of multi-story RC wall buildings. Generic expressions are derived to predict the drift and rotation profiles of multi-storey RC wall buildings. Then, a simple hand calculation method is developed to estimate the system (moment) overstrength of multi-storey RC wall buildings due to system (wall-floor-frames) interaction. The proposed method is applied to a prototype building with different slab dimensions and stiffness, and verified by comparing with the system overstrength factor obtained using finite element analysis. The simplified method estimates, and the nonlinear finite element analyses results agree, that a system overstrength factor of 1.7 can be used to account for the 3D interaction between the structural walls, floors and gravity frames in design and assessment of typical ductile RC wall buildings.\",\"PeriodicalId\":46396,\"journal\":{\"name\":\"Bulletin of the New Zealand Society for Earthquake Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of the New Zealand Society for Earthquake Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5459/bnzsee.55.3.138-154\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, GEOLOGICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the New Zealand Society for Earthquake Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5459/bnzsee.55.3.138-154","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
引用次数: 1

摘要

在多层结构墙建筑中,由于结构墙与楼板和重力抵抗系统的相互作用,结构墙需要抵抗额外的剪力,而当前的抗震设计规定和评估指南并未完全满足这一要求。本文详细研究了多层钢筋混凝土结构墙建筑中钢筋混凝土结构墙体、楼板和重力框架在弹性和非线性响应阶段的相互作用力学。它还研究了这种相互作用对多层RC墙建筑设计的影响。推导了预测多层钢筋混凝土墙结构位移和旋转剖面的通用表达式。然后,发展了一种简单的手工计算方法来估计多层RC墙建筑由于系统(墙-楼板-框架)相互作用而产生的系统(力矩)超强。将所提出的方法应用于具有不同板尺寸和刚度的原型建筑,并通过与有限元分析获得的系统超强因子进行比较来验证。简化方法估计和非线性有限元分析结果一致认为,在典型延性钢筋混凝土墙建筑的设计和评估中,1.7的系统超强系数可用于解释结构墙、楼板和重力框架之间的三维相互作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
System overstrength factor induced by interaction between structural reinforced concrete walls, floors and gravity frames: Analytical formulation
In multi-storey structural wall buildings, the structural walls are required to resist additional shear force due to their interactions with the floors and gravity-resisting system, which is not fully catered for in current seismic design provisions and assessment guidelines. This paper scrutinizes the mechanics of the interaction between structural reinforced concrete (RC) structural walls, floors and gravity frames in multi-storey RC structural wall buildings during elastic and nonlinear response phases. It also investigates the implications of this interaction on design of multi-story RC wall buildings. Generic expressions are derived to predict the drift and rotation profiles of multi-storey RC wall buildings. Then, a simple hand calculation method is developed to estimate the system (moment) overstrength of multi-storey RC wall buildings due to system (wall-floor-frames) interaction. The proposed method is applied to a prototype building with different slab dimensions and stiffness, and verified by comparing with the system overstrength factor obtained using finite element analysis. The simplified method estimates, and the nonlinear finite element analyses results agree, that a system overstrength factor of 1.7 can be used to account for the 3D interaction between the structural walls, floors and gravity frames in design and assessment of typical ductile RC wall buildings.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.50
自引率
17.60%
发文量
14
期刊最新文献
Method to identify if torsional mode of a building is its first mode Earthquake design loads for retaining walls Infrastructure planning emergency levels of service for the Wellington region, Aotearoa New Zealand – An operationalised framework Seismic fragility of reinforced concrete buildings with hollow-core flooring systems Evaluation of the Inter-frequency Correlation of New Zealand CyberShake Crustal Earthquake Simulations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1