高粘性注入过程中单油相变化的观察

IF 2.4 3区 物理与天体物理 Q2 INSTRUMENTS & INSTRUMENTATION Journal of Synchrotron Radiation Pub Date : 2022-05-01 Epub Date: 2022-03-21 DOI:10.1107/S1600577522001862
Daniel J Wells, Peter Berntsen, Eugeniu Balaur, Cameron M Kewish, Patrick Adams, Andrew Aquila, Jack Binns, Sébastien Boutet, Hayden Broomhall, Carl Caleman, Andrew Christofferson, Charlotte E Conn, Caroline Dahlqvist, Leonie Flueckiger, Francisco Gian Roque, Tamar L Greaves, Majid Hejazian, Mark Hunter, Marjan Hadian Jazi, H Olof Jönsson, Sachini Kadaoluwa Pathirannahalage, Richard A Kirian, Alex Kozlov, Ruslan P Kurta, Hugh Marman, Derek Mendez, Andrew Morgan, Keith Nugent, Dominik Oberthuer, Harry Quiney, Juliane Reinhardt, Saumitra Saha, Jonas A Sellberg, Raymond Sierra, Max Wiedorn, Brian Abbey, Andrew V Martin, Connie Darmanin
{"title":"高粘性注入过程中单油相变化的观察","authors":"Daniel J Wells, Peter Berntsen, Eugeniu Balaur, Cameron M Kewish, Patrick Adams, Andrew Aquila, Jack Binns, Sébastien Boutet, Hayden Broomhall, Carl Caleman, Andrew Christofferson, Charlotte E Conn, Caroline Dahlqvist, Leonie Flueckiger, Francisco Gian Roque, Tamar L Greaves, Majid Hejazian, Mark Hunter, Marjan Hadian Jazi, H Olof Jönsson, Sachini Kadaoluwa Pathirannahalage, Richard A Kirian, Alex Kozlov, Ruslan P Kurta, Hugh Marman, Derek Mendez, Andrew Morgan, Keith Nugent, Dominik Oberthuer, Harry Quiney, Juliane Reinhardt, Saumitra Saha, Jonas A Sellberg, Raymond Sierra, Max Wiedorn, Brian Abbey, Andrew V Martin, Connie Darmanin","doi":"10.1107/S1600577522001862","DOIUrl":null,"url":null,"abstract":"<p><p>Serial crystallography of membrane proteins often employs high-viscosity injectors (HVIs) to deliver micrometre-sized crystals to the X-ray beam. Typically, the carrier medium is a lipidic cubic phase (LCP) media, which can also be used to nucleate and grow the crystals. However, despite the fact that the LCP is widely used with HVIs, the potential impact of the injection process on the LCP structure has not been reported and hence is not yet well understood. The self-assembled structure of the LCP can be affected by pressure, dehydration and temperature changes, all of which occur during continuous flow injection. These changes to the LCP structure may in turn impact the results of X-ray diffraction measurements from membrane protein crystals. To investigate the influence of HVIs on the structure of the LCP we conducted a study of the phase changes in monoolein/water and monoolein/buffer mixtures during continuous flow injection, at both atmospheric pressure and under vacuum. The reservoir pressure in the HVI was tracked to determine if there is any correlation with the phase behaviour of the LCP. The results indicated that, even though the reservoir pressure underwent (at times) significant variation, this did not appear to correlate with observed phase changes in the sample stream or correspond to shifts in the LCP lattice parameter. During vacuum injection, there was a three-way coexistence of the gyroid cubic phase, diamond cubic phase and lamellar phase. During injection at atmospheric pressure, the coexistence of a cubic phase and lamellar phase in the monoolein/water mixtures was also observed. The degree to which the lamellar phase is formed was found to be strongly dependent on the co-flowing gas conditions used to stabilize the LCP stream. A combination of laboratory-based optical polarization microscopy and simulation studies was used to investigate these observations.</p>","PeriodicalId":17114,"journal":{"name":"Journal of Synchrotron Radiation","volume":"29 1","pages":"602-614"},"PeriodicalIF":2.4000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9070699/pdf/","citationCount":"0","resultStr":"{\"title\":\"Observations of phase changes in monoolein during high viscous injection.\",\"authors\":\"Daniel J Wells, Peter Berntsen, Eugeniu Balaur, Cameron M Kewish, Patrick Adams, Andrew Aquila, Jack Binns, Sébastien Boutet, Hayden Broomhall, Carl Caleman, Andrew Christofferson, Charlotte E Conn, Caroline Dahlqvist, Leonie Flueckiger, Francisco Gian Roque, Tamar L Greaves, Majid Hejazian, Mark Hunter, Marjan Hadian Jazi, H Olof Jönsson, Sachini Kadaoluwa Pathirannahalage, Richard A Kirian, Alex Kozlov, Ruslan P Kurta, Hugh Marman, Derek Mendez, Andrew Morgan, Keith Nugent, Dominik Oberthuer, Harry Quiney, Juliane Reinhardt, Saumitra Saha, Jonas A Sellberg, Raymond Sierra, Max Wiedorn, Brian Abbey, Andrew V Martin, Connie Darmanin\",\"doi\":\"10.1107/S1600577522001862\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Serial crystallography of membrane proteins often employs high-viscosity injectors (HVIs) to deliver micrometre-sized crystals to the X-ray beam. Typically, the carrier medium is a lipidic cubic phase (LCP) media, which can also be used to nucleate and grow the crystals. However, despite the fact that the LCP is widely used with HVIs, the potential impact of the injection process on the LCP structure has not been reported and hence is not yet well understood. The self-assembled structure of the LCP can be affected by pressure, dehydration and temperature changes, all of which occur during continuous flow injection. These changes to the LCP structure may in turn impact the results of X-ray diffraction measurements from membrane protein crystals. To investigate the influence of HVIs on the structure of the LCP we conducted a study of the phase changes in monoolein/water and monoolein/buffer mixtures during continuous flow injection, at both atmospheric pressure and under vacuum. The reservoir pressure in the HVI was tracked to determine if there is any correlation with the phase behaviour of the LCP. The results indicated that, even though the reservoir pressure underwent (at times) significant variation, this did not appear to correlate with observed phase changes in the sample stream or correspond to shifts in the LCP lattice parameter. During vacuum injection, there was a three-way coexistence of the gyroid cubic phase, diamond cubic phase and lamellar phase. During injection at atmospheric pressure, the coexistence of a cubic phase and lamellar phase in the monoolein/water mixtures was also observed. The degree to which the lamellar phase is formed was found to be strongly dependent on the co-flowing gas conditions used to stabilize the LCP stream. A combination of laboratory-based optical polarization microscopy and simulation studies was used to investigate these observations.</p>\",\"PeriodicalId\":17114,\"journal\":{\"name\":\"Journal of Synchrotron Radiation\",\"volume\":\"29 1\",\"pages\":\"602-614\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2022-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9070699/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Synchrotron Radiation\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1107/S1600577522001862\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/3/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Synchrotron Radiation","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1107/S1600577522001862","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/3/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

这是一项使用高粘度注射器在恒定流量下对单油蛋白样品中检测到的相变的研究。使用X射线技术研究了样品的行为,同时使用光学显微镜和建模研究来帮助解释数据中观察到的一些影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Observations of phase changes in monoolein during high viscous injection.

Serial crystallography of membrane proteins often employs high-viscosity injectors (HVIs) to deliver micrometre-sized crystals to the X-ray beam. Typically, the carrier medium is a lipidic cubic phase (LCP) media, which can also be used to nucleate and grow the crystals. However, despite the fact that the LCP is widely used with HVIs, the potential impact of the injection process on the LCP structure has not been reported and hence is not yet well understood. The self-assembled structure of the LCP can be affected by pressure, dehydration and temperature changes, all of which occur during continuous flow injection. These changes to the LCP structure may in turn impact the results of X-ray diffraction measurements from membrane protein crystals. To investigate the influence of HVIs on the structure of the LCP we conducted a study of the phase changes in monoolein/water and monoolein/buffer mixtures during continuous flow injection, at both atmospheric pressure and under vacuum. The reservoir pressure in the HVI was tracked to determine if there is any correlation with the phase behaviour of the LCP. The results indicated that, even though the reservoir pressure underwent (at times) significant variation, this did not appear to correlate with observed phase changes in the sample stream or correspond to shifts in the LCP lattice parameter. During vacuum injection, there was a three-way coexistence of the gyroid cubic phase, diamond cubic phase and lamellar phase. During injection at atmospheric pressure, the coexistence of a cubic phase and lamellar phase in the monoolein/water mixtures was also observed. The degree to which the lamellar phase is formed was found to be strongly dependent on the co-flowing gas conditions used to stabilize the LCP stream. A combination of laboratory-based optical polarization microscopy and simulation studies was used to investigate these observations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.00%
发文量
289
审稿时长
4-8 weeks
期刊介绍: Synchrotron radiation research is rapidly expanding with many new sources of radiation being created globally. Synchrotron radiation plays a leading role in pure science and in emerging technologies. The Journal of Synchrotron Radiation provides comprehensive coverage of the entire field of synchrotron radiation and free-electron laser research including instrumentation, theory, computing and scientific applications in areas such as biology, nanoscience and materials science. Rapid publication ensures an up-to-date information resource for scientists and engineers in the field.
期刊最新文献
Operando double-edge high-resolution X-ray absorption spectroscopy study of BiVO4 photoanodes Development of dual-beamline photoelectron momentum microscopy for valence orbital analysis Measuring magnetic hysteresis curves with polarized soft X-ray resonant reflectivity High-pressure X-ray photon correlation spectroscopy at fourth-generation synchrotron sources Iterative Bragg peak removal on X-ray absorption spectra with automatic intensity correction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1