Tatjana Mijošek, M. Erk, V. Marijić, N. Krasnići, Zrinka Dragun, D. Ivanković
{"title":"生物监测研究中用改进的Brdička方法电化学测定金属硫蛋白","authors":"Tatjana Mijošek, M. Erk, V. Marijić, N. Krasnići, Zrinka Dragun, D. Ivanković","doi":"10.5562/CCA3444","DOIUrl":null,"url":null,"abstract":"Present study aims to improve the modified Brdicka procedure of metallothionein (MT) quantification in a way to reduce the analysis duration. Therefore, scan rate of the voltammetric sweep was increased from 0.0052 V s–1 to 0.013 V s–1 by lowering the duration of one step potential from 0.5 s to 0.2 s, which resulted in 2.5 times faster voltammetric sweep. Research confirmed high accuracy and reliability of MT measurements, in both standard sample and samples of heat-treated cytosols of liver, gills and the intestine of European chub and liver of brown trout. The method was confirmed as fast and reliable electrochemical technique for quantification of MTs and this time- saving improvement is especially useful and applicable in different biomonitoring studies which require the analyses of numerous biological samples and high sample throughput.","PeriodicalId":10822,"journal":{"name":"Croatica Chemica Acta","volume":"91 1","pages":"475-480"},"PeriodicalIF":0.7000,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Electrochemical Determination of Metallothioneins by the Modified Brdička Procedure as an Analytical Tool in Biomonitoring Studies\",\"authors\":\"Tatjana Mijošek, M. Erk, V. Marijić, N. Krasnići, Zrinka Dragun, D. Ivanković\",\"doi\":\"10.5562/CCA3444\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Present study aims to improve the modified Brdicka procedure of metallothionein (MT) quantification in a way to reduce the analysis duration. Therefore, scan rate of the voltammetric sweep was increased from 0.0052 V s–1 to 0.013 V s–1 by lowering the duration of one step potential from 0.5 s to 0.2 s, which resulted in 2.5 times faster voltammetric sweep. Research confirmed high accuracy and reliability of MT measurements, in both standard sample and samples of heat-treated cytosols of liver, gills and the intestine of European chub and liver of brown trout. The method was confirmed as fast and reliable electrochemical technique for quantification of MTs and this time- saving improvement is especially useful and applicable in different biomonitoring studies which require the analyses of numerous biological samples and high sample throughput.\",\"PeriodicalId\":10822,\"journal\":{\"name\":\"Croatica Chemica Acta\",\"volume\":\"91 1\",\"pages\":\"475-480\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2018-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Croatica Chemica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.5562/CCA3444\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Croatica Chemica Acta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.5562/CCA3444","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 4
摘要
本研究旨在改进金属硫蛋白(MT)定量的改良Brdicka方法,以缩短分析时间。因此,通过将一步电位的持续时间从0.5 s降低到0.2 s,伏安扫描的扫描速率从0.0052 V s–1增加到0.013 V s–2,从而使伏安扫描速度快2.5倍。研究证实了MT测量的高准确性和可靠性,无论是在标准样品还是热处理的欧洲胖鱼肝脏、鳃和肠道的细胞溶质样品中,还是在褐鳟的肝脏中。该方法被证实是一种快速可靠的MT定量电化学技术,这种节省时间的改进在需要分析大量生物样品和高样品通量的不同生物监测研究中尤其有用和适用。
Electrochemical Determination of Metallothioneins by the Modified Brdička Procedure as an Analytical Tool in Biomonitoring Studies
Present study aims to improve the modified Brdicka procedure of metallothionein (MT) quantification in a way to reduce the analysis duration. Therefore, scan rate of the voltammetric sweep was increased from 0.0052 V s–1 to 0.013 V s–1 by lowering the duration of one step potential from 0.5 s to 0.2 s, which resulted in 2.5 times faster voltammetric sweep. Research confirmed high accuracy and reliability of MT measurements, in both standard sample and samples of heat-treated cytosols of liver, gills and the intestine of European chub and liver of brown trout. The method was confirmed as fast and reliable electrochemical technique for quantification of MTs and this time- saving improvement is especially useful and applicable in different biomonitoring studies which require the analyses of numerous biological samples and high sample throughput.
期刊介绍:
Croatica Chemica Acta (Croat. Chem. Acta, CCA), is an international journal of the Croatian Chemical Society publishing scientific articles of general interest to chemistry.