用于光子计数辐射成像系统的PECL逻辑纳秒电压比较器的设计

IF 1 4区 工程技术 Q3 NUCLEAR SCIENCE & TECHNOLOGY Science and Technology of Nuclear Installations Pub Date : 2023-07-08 DOI:10.1155/2023/6810882
Huaxia Zhang, Yuewen Sun, Zijia Chen, Zhifang Wu
{"title":"用于光子计数辐射成像系统的PECL逻辑纳秒电压比较器的设计","authors":"Huaxia Zhang, Yuewen Sun, Zijia Chen, Zhifang Wu","doi":"10.1155/2023/6810882","DOIUrl":null,"url":null,"abstract":"In this paper, a nanosecond voltage comparator with PECL logic for a photon-counting radiation imaging system is presented. To realize a high-speed comparison of four gamma detector channels in a limited board space, quad comparators MAX9602 with PECL logic are chosen. Each of the four channels is coupled with a PECL to CMOS converter ICS508, which exports CMOS logic data for later use in an FPGA. Simulated findings for cobalt-60 with intensities ranging from 30 Ci to 300 Ci show little count loss caused by using a comparator and indicate ideal propagation delays at all source intensities. While in the laboratory test using a PCB-level system, signals with pulse width less than 3 ns might be dropped, and dispersion of propagation delay occurs. Despite these, the performance is still satisfactory and can meet the requirements of practical applications, as demonstrated by an improved result of 0.9% in the contrast indicator model. Further studies to optimize the circuit design can be conducted to gain improvement.","PeriodicalId":21629,"journal":{"name":"Science and Technology of Nuclear Installations","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2023-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of a Nanosecond Voltage Comparator with PECL Logic for a Photon-Counting Radiation Imaging System Application\",\"authors\":\"Huaxia Zhang, Yuewen Sun, Zijia Chen, Zhifang Wu\",\"doi\":\"10.1155/2023/6810882\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a nanosecond voltage comparator with PECL logic for a photon-counting radiation imaging system is presented. To realize a high-speed comparison of four gamma detector channels in a limited board space, quad comparators MAX9602 with PECL logic are chosen. Each of the four channels is coupled with a PECL to CMOS converter ICS508, which exports CMOS logic data for later use in an FPGA. Simulated findings for cobalt-60 with intensities ranging from 30 Ci to 300 Ci show little count loss caused by using a comparator and indicate ideal propagation delays at all source intensities. While in the laboratory test using a PCB-level system, signals with pulse width less than 3 ns might be dropped, and dispersion of propagation delay occurs. Despite these, the performance is still satisfactory and can meet the requirements of practical applications, as demonstrated by an improved result of 0.9% in the contrast indicator model. Further studies to optimize the circuit design can be conducted to gain improvement.\",\"PeriodicalId\":21629,\"journal\":{\"name\":\"Science and Technology of Nuclear Installations\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Science and Technology of Nuclear Installations\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/6810882\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science and Technology of Nuclear Installations","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1155/2023/6810882","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种用于光子计数辐射成像系统的具有PECL逻辑的纳秒电压比较器。为了在有限的板空间内实现四个伽马探测器通道的高速比较,选择了具有PECL逻辑的四比较器MAX9602。四个通道中的每一个都与PECL到CMOS转换器ICS508耦合,该转换器ICS508导出CMOS逻辑数据以供稍后在FPGA中使用。强度范围为30的钴-60的模拟结果 Ci至300 Ci显示由使用比较器引起的计数损失很小,并且指示在所有源强度下的理想传播延迟。在使用PCB电平系统的实验室测试中,脉冲宽度小于3的信号 ns可能下降,并且发生传播延迟的分散。尽管如此,性能仍然令人满意,可以满足实际应用的要求,对比度指标模型的改进结果为0.9%。可以进行进一步的研究来优化电路设计以获得改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design of a Nanosecond Voltage Comparator with PECL Logic for a Photon-Counting Radiation Imaging System Application
In this paper, a nanosecond voltage comparator with PECL logic for a photon-counting radiation imaging system is presented. To realize a high-speed comparison of four gamma detector channels in a limited board space, quad comparators MAX9602 with PECL logic are chosen. Each of the four channels is coupled with a PECL to CMOS converter ICS508, which exports CMOS logic data for later use in an FPGA. Simulated findings for cobalt-60 with intensities ranging from 30 Ci to 300 Ci show little count loss caused by using a comparator and indicate ideal propagation delays at all source intensities. While in the laboratory test using a PCB-level system, signals with pulse width less than 3 ns might be dropped, and dispersion of propagation delay occurs. Despite these, the performance is still satisfactory and can meet the requirements of practical applications, as demonstrated by an improved result of 0.9% in the contrast indicator model. Further studies to optimize the circuit design can be conducted to gain improvement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Science and Technology of Nuclear Installations
Science and Technology of Nuclear Installations NUCLEAR SCIENCE & TECHNOLOGY-
CiteScore
2.30
自引率
9.10%
发文量
51
审稿时长
4-8 weeks
期刊介绍: Science and Technology of Nuclear Installations is an international scientific journal that aims to make available knowledge on issues related to the nuclear industry and to promote development in the area of nuclear sciences and technologies. The endeavor associated with the establishment and the growth of the journal is expected to lend support to the renaissance of nuclear technology in the world and especially in those countries where nuclear programs have not yet been developed.
期刊最新文献
Assessment of Radiation Dose Associated with the Atmospheric Release of 41Ar from the TRIGA Mark-II Research Reactor in Bangladesh Design Change and Operational Consideration of the HVAC System during Nuclear Power Plant Decommissioning Accuracy Evaluation of Monte Carlo Simulation Results Using ENDF/B-VIII.0 and JENDL-5 Libraries for 10 MWth Micro Heat Pipe-Cooled Reactor Effect of Photomultiplier Tube Voltage on the Performance of Sealed NaI (Tl) Scintillator Detectors An Association Rule Mining-Based Method for Revealing the Impact of Operational Sequence on Nuclear Power Plants Operating
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1