对数正态分布矩量法尺度因子校正的细胞平均CFAR检测器

José Raúl Machado Fernández, Jesús de la Concepción Bacallao Vidal
{"title":"对数正态分布矩量法尺度因子校正的细胞平均CFAR检测器","authors":"José Raúl Machado Fernández, Jesús de la Concepción Bacallao Vidal","doi":"10.18359/RCIN.2408","DOIUrl":null,"url":null,"abstract":"The new LN-MoM-CA-CFAR detector is introduced, exhibiting a reduced deviation of the operational false alarm probability from the value conceived in the design. The solution solves a fundamental problem of CFAR processors that has been ignored in most proposals. Indeed, most of the previously proposed schemes deal with sudden changes in the clutter level, whereas the new solution has an improved performance against slow statistical changes that occur in the background signal. It has been proven that these slow changes have a remarkable influence on the selection of the CFAR adjustment factor, and consequently in maintaining the false alarm probability. The authors took advantage of the high precision achieved by the MoM (Method of Moments) in the estimation of the Log-Normal (LN) shape parameter, and the wide application of this distribution to radar clutter modeling, to create an architecture that offers precise results and it’s computationally inexpensive at the same time. After an intensive processing, involving 100 million Log-Normal samples, a scheme, which operates with excellent stability reaching a deviation of only 0,2884 % for the probability of false alarm of 0,01, was created, improving the classical CA-CFAR detector through the continuous correction of its scale factor.","PeriodicalId":31201,"journal":{"name":"Ciencia e Ingenieria Neogranadina","volume":"28 1","pages":"27-44"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Cell Averaging CFAR Detector with Scale Factor Correction through the Method of Moments for the Log-Normal Distribution\",\"authors\":\"José Raúl Machado Fernández, Jesús de la Concepción Bacallao Vidal\",\"doi\":\"10.18359/RCIN.2408\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The new LN-MoM-CA-CFAR detector is introduced, exhibiting a reduced deviation of the operational false alarm probability from the value conceived in the design. The solution solves a fundamental problem of CFAR processors that has been ignored in most proposals. Indeed, most of the previously proposed schemes deal with sudden changes in the clutter level, whereas the new solution has an improved performance against slow statistical changes that occur in the background signal. It has been proven that these slow changes have a remarkable influence on the selection of the CFAR adjustment factor, and consequently in maintaining the false alarm probability. The authors took advantage of the high precision achieved by the MoM (Method of Moments) in the estimation of the Log-Normal (LN) shape parameter, and the wide application of this distribution to radar clutter modeling, to create an architecture that offers precise results and it’s computationally inexpensive at the same time. After an intensive processing, involving 100 million Log-Normal samples, a scheme, which operates with excellent stability reaching a deviation of only 0,2884 % for the probability of false alarm of 0,01, was created, improving the classical CA-CFAR detector through the continuous correction of its scale factor.\",\"PeriodicalId\":31201,\"journal\":{\"name\":\"Ciencia e Ingenieria Neogranadina\",\"volume\":\"28 1\",\"pages\":\"27-44\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ciencia e Ingenieria Neogranadina\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18359/RCIN.2408\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ciencia e Ingenieria Neogranadina","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18359/RCIN.2408","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

介绍了一种新的LN MoM CA CFAR检测器,它减少了操作虚警概率与设计中设想的值的偏差。该解决方案解决了CFAR处理器的一个基本问题,该问题在大多数提案中都被忽视了。事实上,以前提出的大多数方案都处理杂波电平的突然变化,而新的解决方案在对抗背景信号中发生的缓慢统计变化时具有改进的性能。已经证明,这些缓慢的变化对CFAR调整因子的选择有显著影响,从而对保持误报概率有显著影响。作者利用MoM(矩量法)在对数正态(LN)形状参数估计中实现的高精度,以及这种分布在雷达杂波建模中的广泛应用,创建了一种既能提供精确结果又计算成本低廉的架构。经过涉及1亿个对数正态样本的密集处理,创建了一个方案,该方案具有良好的稳定性,在误报概率为0,01时,偏差仅为02884%,通过对其比例因子的连续校正来改进经典的CA-CFAR检测器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Cell Averaging CFAR Detector with Scale Factor Correction through the Method of Moments for the Log-Normal Distribution
The new LN-MoM-CA-CFAR detector is introduced, exhibiting a reduced deviation of the operational false alarm probability from the value conceived in the design. The solution solves a fundamental problem of CFAR processors that has been ignored in most proposals. Indeed, most of the previously proposed schemes deal with sudden changes in the clutter level, whereas the new solution has an improved performance against slow statistical changes that occur in the background signal. It has been proven that these slow changes have a remarkable influence on the selection of the CFAR adjustment factor, and consequently in maintaining the false alarm probability. The authors took advantage of the high precision achieved by the MoM (Method of Moments) in the estimation of the Log-Normal (LN) shape parameter, and the wide application of this distribution to radar clutter modeling, to create an architecture that offers precise results and it’s computationally inexpensive at the same time. After an intensive processing, involving 100 million Log-Normal samples, a scheme, which operates with excellent stability reaching a deviation of only 0,2884 % for the probability of false alarm of 0,01, was created, improving the classical CA-CFAR detector through the continuous correction of its scale factor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
9
审稿时长
20 weeks
期刊最新文献
Editorial Exploración del efecto de la integración de herramientas con agentividad en ambientes de aprendizaje Performance of a Series of Polishing Ponds in the Treatment of Sanitary Sewage Sistemas de detección y prevención de intrusos Análisis de la huella hídrica azul como indicador de sostenibilidad en pymes del Valle del Cauca
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1