F2 MC管作为被动可调谐减振器的改进

IF 2.1 3区 工程技术 Q2 ENGINEERING, CIVIL Smart Structures and Systems Pub Date : 2021-08-01 DOI:10.12989/SSS.2021.28.2.153
Shiren O. Muhammad, N. A. Hussain
{"title":"F2 MC管作为被动可调谐减振器的改进","authors":"Shiren O. Muhammad, N. A. Hussain","doi":"10.12989/SSS.2021.28.2.153","DOIUrl":null,"url":null,"abstract":"This paper presents new parameters for damping improvement in F2MC tubes performance as tunable vibration absorbers. They offer very good performance with environments having susceptibility to high frequency vibration noise. This study highlights the behavior of changing some parameters of F2MC tubes which never have been studied before. These parameters include thickness ratio between each two respective layers and fluid type that the tubes are filled with. In this paper the beam governing equations with the tube's stress analyses equations are solved for finding the combined system's response by MATLAB® software function solvers. To ensure accuracy of modifications, validations have been proposed by performing illustrative examples and comparing the results with the existing data available in literature. The results showed improvements of F2MC tubes performance 20% over previous studies achievements by studying the thickness ratio, and another 12.82% can be added by using glycerin instead of water under the same conditions. Finally, the reduction of 34.34 dB in first mode amplitude of vibration was achieved in the beam's frequency response function plot.","PeriodicalId":51155,"journal":{"name":"Smart Structures and Systems","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2021-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modifications on F 2 MC tubes as passive tunable vibration absorbers\",\"authors\":\"Shiren O. Muhammad, N. A. Hussain\",\"doi\":\"10.12989/SSS.2021.28.2.153\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents new parameters for damping improvement in F2MC tubes performance as tunable vibration absorbers. They offer very good performance with environments having susceptibility to high frequency vibration noise. This study highlights the behavior of changing some parameters of F2MC tubes which never have been studied before. These parameters include thickness ratio between each two respective layers and fluid type that the tubes are filled with. In this paper the beam governing equations with the tube's stress analyses equations are solved for finding the combined system's response by MATLAB® software function solvers. To ensure accuracy of modifications, validations have been proposed by performing illustrative examples and comparing the results with the existing data available in literature. The results showed improvements of F2MC tubes performance 20% over previous studies achievements by studying the thickness ratio, and another 12.82% can be added by using glycerin instead of water under the same conditions. Finally, the reduction of 34.34 dB in first mode amplitude of vibration was achieved in the beam's frequency response function plot.\",\"PeriodicalId\":51155,\"journal\":{\"name\":\"Smart Structures and Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2021-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Smart Structures and Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.12989/SSS.2021.28.2.153\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Smart Structures and Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.12989/SSS.2021.28.2.153","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了新的参数,以改善F2MC管作为可调谐减振器的阻尼性能。它们在易受高频振动噪声影响的环境中提供了非常好的性能。这项研究强调了改变F2MC管的一些参数的行为,这是以前从未研究过的。这些参数包括每两个相应层之间的厚度比和管中填充的流体类型。本文通过MATLAB®软件函数求解器求解梁的控制方程和管的应力分析方程,以求得组合系统的响应。为了确保修改的准确性,已经通过执行示例并将结果与文献中现有的数据进行比较来提出验证。结果表明,通过研究厚度比,F2MC管的性能比以前的研究成果提高了20%,在相同条件下,用甘油代替水可以再提高12.82%。最后,在梁的频率响应函数图中,实现了34.34dB的一阶模态振幅降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Modifications on F 2 MC tubes as passive tunable vibration absorbers
This paper presents new parameters for damping improvement in F2MC tubes performance as tunable vibration absorbers. They offer very good performance with environments having susceptibility to high frequency vibration noise. This study highlights the behavior of changing some parameters of F2MC tubes which never have been studied before. These parameters include thickness ratio between each two respective layers and fluid type that the tubes are filled with. In this paper the beam governing equations with the tube's stress analyses equations are solved for finding the combined system's response by MATLAB® software function solvers. To ensure accuracy of modifications, validations have been proposed by performing illustrative examples and comparing the results with the existing data available in literature. The results showed improvements of F2MC tubes performance 20% over previous studies achievements by studying the thickness ratio, and another 12.82% can be added by using glycerin instead of water under the same conditions. Finally, the reduction of 34.34 dB in first mode amplitude of vibration was achieved in the beam's frequency response function plot.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Smart Structures and Systems
Smart Structures and Systems 工程技术-工程:机械
CiteScore
6.50
自引率
8.60%
发文量
0
审稿时长
9 months
期刊介绍: An International Journal of Mechatronics, Sensors, Monitoring, Control, Diagnosis, and Management airns at providing a major publication channel for researchers in the general area of smart structures and systems. Typical subjects considered by the journal include: Sensors/Actuators(Materials/devices/ informatics/networking) Structural Health Monitoring and Control Diagnosis/Prognosis Life Cycle Engineering(planning/design/ maintenance/renewal) and related areas.
期刊最新文献
Analysis, optimization and control of an adaptive tuned vibration absorber featuring magnetoactive materials Numerical investigation on cyclic behaviour of superelastic shape memory alloy (SMA) dampers Hybrid fragility curve derivation of buildings based on post-earthquake reconnaissance data A corrosion threshold-controllable sensing system of Fe-C coated long period fiber gratings for life-cycle mass loss measurement of steel bars with strain and temperature compensation Steel dual-ring dampers: Micro-finite element modelling and validation of cyclic behavior
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1