S. Pinem, S. Dibyo, W. Luthfi, V. Wardhani, D. Hartanto
{"title":"改进的基于MTR-DYN和EUREKA-2/RR程序的RSG-GAS堆芯RIA工况稳态和瞬态分析","authors":"S. Pinem, S. Dibyo, W. Luthfi, V. Wardhani, D. Hartanto","doi":"10.1155/2022/6030504","DOIUrl":null,"url":null,"abstract":"Steady-state and transient analysis of reactor core under Reactivity-Initiated Accident (RIA) conditions are important for reactor operation safety. The reactor dynamics are influenced by neutronic and thermal-hydraulic aspects of the core. In this study, steady-state and transient analysis under RIA conditions of the RSG-GAS multipurpose reactor was carried out using MTR-DYN and EUREKA-2/RR programs. Neutronic calculations were performed using a few group cross-sections generated by Serpent 2 with the latest cross-section data ENDF/B-VIII.0. Steady-state conditions were carried out with a nominal power of 30 MW, while transient under RIA conditions occurred because the control rod was pulled too quickly while the reactor operated. These transient RIA conditions were performed for two cases, during start-up with an initial power of 1 W, and within power range with an initial power of 1 MW. Thermal-hydraulic parameters considered in this study are reactor power, the temperature of the fuel, cladding, and coolant. The calculated maximum fuel temperature at a steady state is 126.02°C. Meanwhile, the calculated maximum fuel temperature during RIA conditions at the initial power of 1 W and 1 MW are 64.38°C and 137.14°C, respectively. There are no significant differences in thermal-hydraulic parameters between each used program. The thermal-hydraulic parameters such as the maximum temperature of the coolant, cladding, and fuel under this postulated RIA condition are within the acceptable reactor operation safety limits.","PeriodicalId":21629,"journal":{"name":"Science and Technology of Nuclear Installations","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2022-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An Improved Steady-State and Transient Analysis of the RSG-GAS Reactor Core under RIA Conditions Using MTR-DYN and EUREKA-2/RR Codes\",\"authors\":\"S. Pinem, S. Dibyo, W. Luthfi, V. Wardhani, D. Hartanto\",\"doi\":\"10.1155/2022/6030504\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Steady-state and transient analysis of reactor core under Reactivity-Initiated Accident (RIA) conditions are important for reactor operation safety. The reactor dynamics are influenced by neutronic and thermal-hydraulic aspects of the core. In this study, steady-state and transient analysis under RIA conditions of the RSG-GAS multipurpose reactor was carried out using MTR-DYN and EUREKA-2/RR programs. Neutronic calculations were performed using a few group cross-sections generated by Serpent 2 with the latest cross-section data ENDF/B-VIII.0. Steady-state conditions were carried out with a nominal power of 30 MW, while transient under RIA conditions occurred because the control rod was pulled too quickly while the reactor operated. These transient RIA conditions were performed for two cases, during start-up with an initial power of 1 W, and within power range with an initial power of 1 MW. Thermal-hydraulic parameters considered in this study are reactor power, the temperature of the fuel, cladding, and coolant. The calculated maximum fuel temperature at a steady state is 126.02°C. Meanwhile, the calculated maximum fuel temperature during RIA conditions at the initial power of 1 W and 1 MW are 64.38°C and 137.14°C, respectively. There are no significant differences in thermal-hydraulic parameters between each used program. The thermal-hydraulic parameters such as the maximum temperature of the coolant, cladding, and fuel under this postulated RIA condition are within the acceptable reactor operation safety limits.\",\"PeriodicalId\":21629,\"journal\":{\"name\":\"Science and Technology of Nuclear Installations\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2022-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Science and Technology of Nuclear Installations\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1155/2022/6030504\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science and Technology of Nuclear Installations","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1155/2022/6030504","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
An Improved Steady-State and Transient Analysis of the RSG-GAS Reactor Core under RIA Conditions Using MTR-DYN and EUREKA-2/RR Codes
Steady-state and transient analysis of reactor core under Reactivity-Initiated Accident (RIA) conditions are important for reactor operation safety. The reactor dynamics are influenced by neutronic and thermal-hydraulic aspects of the core. In this study, steady-state and transient analysis under RIA conditions of the RSG-GAS multipurpose reactor was carried out using MTR-DYN and EUREKA-2/RR programs. Neutronic calculations were performed using a few group cross-sections generated by Serpent 2 with the latest cross-section data ENDF/B-VIII.0. Steady-state conditions were carried out with a nominal power of 30 MW, while transient under RIA conditions occurred because the control rod was pulled too quickly while the reactor operated. These transient RIA conditions were performed for two cases, during start-up with an initial power of 1 W, and within power range with an initial power of 1 MW. Thermal-hydraulic parameters considered in this study are reactor power, the temperature of the fuel, cladding, and coolant. The calculated maximum fuel temperature at a steady state is 126.02°C. Meanwhile, the calculated maximum fuel temperature during RIA conditions at the initial power of 1 W and 1 MW are 64.38°C and 137.14°C, respectively. There are no significant differences in thermal-hydraulic parameters between each used program. The thermal-hydraulic parameters such as the maximum temperature of the coolant, cladding, and fuel under this postulated RIA condition are within the acceptable reactor operation safety limits.
期刊介绍:
Science and Technology of Nuclear Installations is an international scientific journal that aims to make available knowledge on issues related to the nuclear industry and to promote development in the area of nuclear sciences and technologies. The endeavor associated with the establishment and the growth of the journal is expected to lend support to the renaissance of nuclear technology in the world and especially in those countries where nuclear programs have not yet been developed.