{"title":"腰椎融合术后医源性肌肉韧带复合损伤对邻近节段的生物力学影响:有限元分析。","authors":"Wei Wei, Tianhao Wang, Jian Li, Jianheng Liu, Keya Mao, Chun'ang Pan, Hui Li, Yongfei Zhao","doi":"10.1177/03913988231203586","DOIUrl":null,"url":null,"abstract":"Objective: To analyze the biomechanical effects of proximal iatrogenic muscle-ligaments complex (MLC) damage on adjacent segments following posterior lumbar interbody fusion (PLIF) by finite element (FE) analysis. Methods: The multifidus muscle force was loaded in the validated intact lumbosacral finite element model. Based on whether undergoing PLIF or the proximal MLC damage, three models were established. Range of motion (ROM) and the maximum von Mises (VM) stress of adjacent segments were analyzed, as well as the average muscle force and work capacity in four loading directions. Results: PLIF results in significant changes in ROM and stress. ROM changed significantly in the upper adjacent segment, the PLIF model changed the most in extension, and the largest change in the lower adjacent segment occurred after MLC damage. The VM stress of the upper adjacent segment occurred in extension of the PLIF model, and that of the lower adjacent segment occurred in rotation after MLC damage. In flexion, ROM, and stress of the damaged MLC fusion model were significantly increased compared with the normal and PLIF models, there was a stepwise amplification. The average muscle force comparison of three models was 5.8530, 12.3185, and 13.4670 N, respectively. The total work capacity comparison was close to that of muscle force. Conclusion: PLIF results in increased ROM and the VM stress of adjacent segments, the proximal MLC damage will aggravate this change. This may increase the risk of ASD and chronic low back pain. Preserving the proximal MLC reduces the biomechanical effects on adjacent segments.","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biomechanical effects of iatrogenic muscle-ligaments complex damage on adjacent segments following posterior lumbar interbody fusion: A finite element analysis.\",\"authors\":\"Wei Wei, Tianhao Wang, Jian Li, Jianheng Liu, Keya Mao, Chun'ang Pan, Hui Li, Yongfei Zhao\",\"doi\":\"10.1177/03913988231203586\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: To analyze the biomechanical effects of proximal iatrogenic muscle-ligaments complex (MLC) damage on adjacent segments following posterior lumbar interbody fusion (PLIF) by finite element (FE) analysis. Methods: The multifidus muscle force was loaded in the validated intact lumbosacral finite element model. Based on whether undergoing PLIF or the proximal MLC damage, three models were established. Range of motion (ROM) and the maximum von Mises (VM) stress of adjacent segments were analyzed, as well as the average muscle force and work capacity in four loading directions. Results: PLIF results in significant changes in ROM and stress. ROM changed significantly in the upper adjacent segment, the PLIF model changed the most in extension, and the largest change in the lower adjacent segment occurred after MLC damage. The VM stress of the upper adjacent segment occurred in extension of the PLIF model, and that of the lower adjacent segment occurred in rotation after MLC damage. In flexion, ROM, and stress of the damaged MLC fusion model were significantly increased compared with the normal and PLIF models, there was a stepwise amplification. The average muscle force comparison of three models was 5.8530, 12.3185, and 13.4670 N, respectively. The total work capacity comparison was close to that of muscle force. Conclusion: PLIF results in increased ROM and the VM stress of adjacent segments, the proximal MLC damage will aggravate this change. This may increase the risk of ASD and chronic low back pain. Preserving the proximal MLC reduces the biomechanical effects on adjacent segments.\",\"PeriodicalId\":13932,\"journal\":{\"name\":\"International Journal of Artificial Organs\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/03913988231203586\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988231203586","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/21 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Biomechanical effects of iatrogenic muscle-ligaments complex damage on adjacent segments following posterior lumbar interbody fusion: A finite element analysis.
Objective: To analyze the biomechanical effects of proximal iatrogenic muscle-ligaments complex (MLC) damage on adjacent segments following posterior lumbar interbody fusion (PLIF) by finite element (FE) analysis. Methods: The multifidus muscle force was loaded in the validated intact lumbosacral finite element model. Based on whether undergoing PLIF or the proximal MLC damage, three models were established. Range of motion (ROM) and the maximum von Mises (VM) stress of adjacent segments were analyzed, as well as the average muscle force and work capacity in four loading directions. Results: PLIF results in significant changes in ROM and stress. ROM changed significantly in the upper adjacent segment, the PLIF model changed the most in extension, and the largest change in the lower adjacent segment occurred after MLC damage. The VM stress of the upper adjacent segment occurred in extension of the PLIF model, and that of the lower adjacent segment occurred in rotation after MLC damage. In flexion, ROM, and stress of the damaged MLC fusion model were significantly increased compared with the normal and PLIF models, there was a stepwise amplification. The average muscle force comparison of three models was 5.8530, 12.3185, and 13.4670 N, respectively. The total work capacity comparison was close to that of muscle force. Conclusion: PLIF results in increased ROM and the VM stress of adjacent segments, the proximal MLC damage will aggravate this change. This may increase the risk of ASD and chronic low back pain. Preserving the proximal MLC reduces the biomechanical effects on adjacent segments.
期刊介绍:
The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.