用于心脏导管和多节段松弛模拟器的导丝模型的高阶近似

Presence Pub Date : 2021-02-23 DOI:10.1162/pres_a_00334
Jürgen A. Baier-Saip;Pablo A. Baier;Jauvane C. Oliveira;Herbert Baier
{"title":"用于心脏导管和多节段松弛模拟器的导丝模型的高阶近似","authors":"Jürgen A. Baier-Saip;Pablo A. Baier;Jauvane C. Oliveira;Herbert Baier","doi":"10.1162/pres_a_00334","DOIUrl":null,"url":null,"abstract":"<para>Cardiac catheterism is important because it offers many advantages in comparison to open surgery, for example, fewer injuries, lower risk of infections, and shorter recovery times. Simulators play a fundamental role in training packages, and virtual learning environments are less stressful. Moreover, they can also be used in certification boards and in performance assessments. A realistic and interactive simulator must be fast. In this work, the physical model of the guidewire used in catheter simulations has been improved. In particular, we determined a simple analytic expression to calculate the direction of a guidewire segment, which minimizes the total energy. The surface energy resulting from the guidewire--artery interaction and the bending energy of the guidewire is approximated up to the second order, which gives rise to interactions between segments. Furthermore, the multiple segment relaxations are introduced, enhancing the convergence especially at the beginning of the relaxation cycle. The formulas are written in matrix form of dimension <inline-formula><mml:math><mml:mrow><mml:mn>4</mml:mn><mml:mi>M</mml:mi><mml:mo>×</mml:mo><mml:mn>4</mml:mn><mml:mi>M</mml:mi></mml:mrow></mml:math></inline-formula>, where <inline-formula><mml:math><mml:mi>M</mml:mi></mml:math></inline-formula> represents the number of segments varied in the update step. The method results in a more stable static solution.</para>","PeriodicalId":101038,"journal":{"name":"Presence","volume":"27 4","pages":"333-360"},"PeriodicalIF":0.0000,"publicationDate":"2021-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Higher-Order Approximation to the Guidewire Model Used in Simulators of Cardiac Catheterization and Multiple Segment Relaxations\",\"authors\":\"Jürgen A. Baier-Saip;Pablo A. Baier;Jauvane C. Oliveira;Herbert Baier\",\"doi\":\"10.1162/pres_a_00334\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<para>Cardiac catheterism is important because it offers many advantages in comparison to open surgery, for example, fewer injuries, lower risk of infections, and shorter recovery times. Simulators play a fundamental role in training packages, and virtual learning environments are less stressful. Moreover, they can also be used in certification boards and in performance assessments. A realistic and interactive simulator must be fast. In this work, the physical model of the guidewire used in catheter simulations has been improved. In particular, we determined a simple analytic expression to calculate the direction of a guidewire segment, which minimizes the total energy. The surface energy resulting from the guidewire--artery interaction and the bending energy of the guidewire is approximated up to the second order, which gives rise to interactions between segments. Furthermore, the multiple segment relaxations are introduced, enhancing the convergence especially at the beginning of the relaxation cycle. The formulas are written in matrix form of dimension <inline-formula><mml:math><mml:mrow><mml:mn>4</mml:mn><mml:mi>M</mml:mi><mml:mo>×</mml:mo><mml:mn>4</mml:mn><mml:mi>M</mml:mi></mml:mrow></mml:math></inline-formula>, where <inline-formula><mml:math><mml:mi>M</mml:mi></mml:math></inline-formula> represents the number of segments varied in the update step. The method results in a more stable static solution.</para>\",\"PeriodicalId\":101038,\"journal\":{\"name\":\"Presence\",\"volume\":\"27 4\",\"pages\":\"333-360\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-02-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Presence\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/9361516/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Presence","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/9361516/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

心导管术很重要,因为与开放手术相比,它具有许多优点,例如,损伤更少,感染风险更低,恢复时间更短。模拟器在培训包中发挥着重要作用,虚拟学习环境压力较小。此外,它们还可用于认证委员会和绩效评估。一个逼真的交互式模拟器必须是快速的。在这项工作中,导管模拟中使用的导丝的物理模型得到了改进。特别是,我们确定了一个简单的解析表达式来计算导丝段的方向,该表达式使总能量最小化。导丝-动脉相互作用产生的表面能和导丝的弯曲能近似为二阶,这导致了节段之间的相互作用。此外,引入了多段弛豫,特别是在弛豫周期开始时增强了收敛性。公式以4M×4M的矩阵形式编写,其中M表示在更新步骤中变化的分段数量。该方法得到了更稳定的静态解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Higher-Order Approximation to the Guidewire Model Used in Simulators of Cardiac Catheterization and Multiple Segment Relaxations
Cardiac catheterism is important because it offers many advantages in comparison to open surgery, for example, fewer injuries, lower risk of infections, and shorter recovery times. Simulators play a fundamental role in training packages, and virtual learning environments are less stressful. Moreover, they can also be used in certification boards and in performance assessments. A realistic and interactive simulator must be fast. In this work, the physical model of the guidewire used in catheter simulations has been improved. In particular, we determined a simple analytic expression to calculate the direction of a guidewire segment, which minimizes the total energy. The surface energy resulting from the guidewire--artery interaction and the bending energy of the guidewire is approximated up to the second order, which gives rise to interactions between segments. Furthermore, the multiple segment relaxations are introduced, enhancing the convergence especially at the beginning of the relaxation cycle. The formulas are written in matrix form of dimension 4M×4M, where M represents the number of segments varied in the update step. The method results in a more stable static solution.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Mismatches between 3D Content Acquisition and Perception Cause More Visually Induced Motion Sickness Tokens of Reality: On the Prospective Nature of Virtual Consciousness Bridging the Headset: Engagement, Collaboration, and Learning in and around Virtual Reality How Interaction Techniques Affect Workload in a Virtual Environment During Multitasking Ten Years of Operating a Center with Large-Scale Virtual-Reality Installations: Developments and Learnings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1