基于同步测量的线路参数估计中电流互感器行为的精细建模与补偿

Christian Laurano;Paolo Attilio Pegoraro;Carlo Sitzia;Antonio Vincenzo Solinas;Sara Sulis;Sergio Toscani
{"title":"基于同步测量的线路参数估计中电流互感器行为的精细建模与补偿","authors":"Christian Laurano;Paolo Attilio Pegoraro;Carlo Sitzia;Antonio Vincenzo Solinas;Sara Sulis;Sergio Toscani","doi":"10.1109/OJIM.2023.3250280","DOIUrl":null,"url":null,"abstract":"Nowadays, in modern management and control applications, line parameters need to be known more accurately than in the past to achieve a reliable operation of the distribution grids. Phasor measurement units (PMUs) may improve line parameter estimation processes, but the accuracy of the result is affected by all the elements of the PMU-based measurement chain, in particular by the instrument transformers. Current transformers (CTs) are nonlinear and, therefore, their behavior is not easily described: their models cannot be straightforwardly included in the estimation problem. In this regard, this article refines modeling and compensation of CT systematic errors in line parameter estimation processes, based on different methods to describe the transformer behavior under various operating conditions. As the main result, the systematic errors of CTs are remarkably identified and mitigated. Moreover, the estimation of shunt susceptance values is significantly improved.","PeriodicalId":100630,"journal":{"name":"IEEE Open Journal of Instrumentation and Measurement","volume":"2 ","pages":"1-11"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/9552935/10025401/10056410.pdf","citationCount":"0","resultStr":"{\"title\":\"Refined Modeling and Compensation of Current Transformers Behavior for Line Parameters Estimation Based on Synchronized Measurements\",\"authors\":\"Christian Laurano;Paolo Attilio Pegoraro;Carlo Sitzia;Antonio Vincenzo Solinas;Sara Sulis;Sergio Toscani\",\"doi\":\"10.1109/OJIM.2023.3250280\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Nowadays, in modern management and control applications, line parameters need to be known more accurately than in the past to achieve a reliable operation of the distribution grids. Phasor measurement units (PMUs) may improve line parameter estimation processes, but the accuracy of the result is affected by all the elements of the PMU-based measurement chain, in particular by the instrument transformers. Current transformers (CTs) are nonlinear and, therefore, their behavior is not easily described: their models cannot be straightforwardly included in the estimation problem. In this regard, this article refines modeling and compensation of CT systematic errors in line parameter estimation processes, based on different methods to describe the transformer behavior under various operating conditions. As the main result, the systematic errors of CTs are remarkably identified and mitigated. Moreover, the estimation of shunt susceptance values is significantly improved.\",\"PeriodicalId\":100630,\"journal\":{\"name\":\"IEEE Open Journal of Instrumentation and Measurement\",\"volume\":\"2 \",\"pages\":\"1-11\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/iel7/9552935/10025401/10056410.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Open Journal of Instrumentation and Measurement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10056410/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of Instrumentation and Measurement","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10056410/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

如今,在现代管理和控制应用中,需要比过去更准确地知道线路参数,以实现配电网的可靠运行。相量测量单元(PMU)可以改进线路参数估计过程,但结果的准确性受到基于PMU的测量链的所有元素的影响,特别是受到仪器变压器的影响。电流互感器是非线性的,因此,它们的行为不容易描述:它们的模型不能直接包含在估计问题中。在这方面,本文基于描述变压器在各种运行条件下行为的不同方法,对线路参数估计过程中CT系统误差的建模和补偿进行了改进。主要结果是,CT的系统误差得到了显著识别和缓解。此外,分流电纳值的估计得到了显著改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Refined Modeling and Compensation of Current Transformers Behavior for Line Parameters Estimation Based on Synchronized Measurements
Nowadays, in modern management and control applications, line parameters need to be known more accurately than in the past to achieve a reliable operation of the distribution grids. Phasor measurement units (PMUs) may improve line parameter estimation processes, but the accuracy of the result is affected by all the elements of the PMU-based measurement chain, in particular by the instrument transformers. Current transformers (CTs) are nonlinear and, therefore, their behavior is not easily described: their models cannot be straightforwardly included in the estimation problem. In this regard, this article refines modeling and compensation of CT systematic errors in line parameter estimation processes, based on different methods to describe the transformer behavior under various operating conditions. As the main result, the systematic errors of CTs are remarkably identified and mitigated. Moreover, the estimation of shunt susceptance values is significantly improved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Spatiotemporal Variance Image Reconstruction for Thermographic Inspections Fault Detection in an Electro-Hydrostatic Actuator Using Polyscale Complexity Measures and Bayesian Classification Baseline-Free Damage Imaging for Structural Health Monitoring of Composite Lap Joint Using Ultrasonic-Guided Waves Spiking Neural Networks for Energy-Efficient Acoustic Emission-Based Monitoring IMU Optimal Rotation Rates
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1