{"title":"对血糖仪4型血糖系统用于近患者检测的适用性评估","authors":"M. Powell","doi":"10.1002/j.1528-252X.1994.tb00026.x","DOIUrl":null,"url":null,"abstract":"The performance of a new system for near‐patient monitoring of blood glucose levels based on the reference hexokinase/glucose‐6‐phosphate dehydrogenase method was evaluated in a routine out‐patient diabetes clinic. The system includes features designed to overcome operator dependency of results. Within‐batch precision was 1.1‐4.2% coefficient of variation, while between‐batch coefficients of variation of 2.6‐6.7% were achieved. The new system was assessed to be suitable for use by nurses and patients.","PeriodicalId":92116,"journal":{"name":"Practical diabetes international : the journal for diabetes care teams worldwide","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/j.1528-252X.1994.tb00026.x","citationCount":"1","resultStr":"{\"title\":\"An assessment of the suitability of the Glucometer 4 blood glucose system for near‐patient testing\",\"authors\":\"M. Powell\",\"doi\":\"10.1002/j.1528-252X.1994.tb00026.x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The performance of a new system for near‐patient monitoring of blood glucose levels based on the reference hexokinase/glucose‐6‐phosphate dehydrogenase method was evaluated in a routine out‐patient diabetes clinic. The system includes features designed to overcome operator dependency of results. Within‐batch precision was 1.1‐4.2% coefficient of variation, while between‐batch coefficients of variation of 2.6‐6.7% were achieved. The new system was assessed to be suitable for use by nurses and patients.\",\"PeriodicalId\":92116,\"journal\":{\"name\":\"Practical diabetes international : the journal for diabetes care teams worldwide\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/j.1528-252X.1994.tb00026.x\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Practical diabetes international : the journal for diabetes care teams worldwide\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/j.1528-252X.1994.tb00026.x\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Practical diabetes international : the journal for diabetes care teams worldwide","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/j.1528-252X.1994.tb00026.x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An assessment of the suitability of the Glucometer 4 blood glucose system for near‐patient testing
The performance of a new system for near‐patient monitoring of blood glucose levels based on the reference hexokinase/glucose‐6‐phosphate dehydrogenase method was evaluated in a routine out‐patient diabetes clinic. The system includes features designed to overcome operator dependency of results. Within‐batch precision was 1.1‐4.2% coefficient of variation, while between‐batch coefficients of variation of 2.6‐6.7% were achieved. The new system was assessed to be suitable for use by nurses and patients.