{"title":"控制离心泵","authors":"W. C. Driedger","doi":"10.1002/9781119267799.ch18","DOIUrl":null,"url":null,"abstract":"Several options are available to match pump operating point to the process and still ensure system reliability. Assuming the pump is more than adequate for the process requirements at the moment, what is the best way to trim it to the desired operating point? There are three possible locations to place a valve: on the discharge, suction, or use a recycle valve. The paper discusses valve placement in all three options. Using the example of a pump drawing volatile hydrocarbons from a large surge vessel, the following features are discussed: a level/flow cascade loop on the pump discharge to provide process control; a check valve on the discharge downstream of the control valve to prevent reverse flow when the pump is shut down; a fire safe motor operated valve (MOV) in case of seal leakage and fires; an interlock from the MOV to stop the pump if the valve is not fully opened; a low level interlock from the vessel to stop the pump if the vessel loses its liquid seal; a pressure gauge on the suction to indicate adequate NPSHA; a thermometer on the suction to indicate potentially high vapor pressure; a minimum flow recycle loop back to themore » vessel; a check valve on the recycle line to prevent reverse flow when the pump is shut down, especially when the fire valve is closed; and a pressure gauge on the pump discharge to indicate that the pump is working.« less","PeriodicalId":55043,"journal":{"name":"Hydrocarbon Processing","volume":"93 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"1995-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/9781119267799.ch18","citationCount":"13","resultStr":"{\"title\":\"Controlling centrifugal pumps\",\"authors\":\"W. C. Driedger\",\"doi\":\"10.1002/9781119267799.ch18\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Several options are available to match pump operating point to the process and still ensure system reliability. Assuming the pump is more than adequate for the process requirements at the moment, what is the best way to trim it to the desired operating point? There are three possible locations to place a valve: on the discharge, suction, or use a recycle valve. The paper discusses valve placement in all three options. Using the example of a pump drawing volatile hydrocarbons from a large surge vessel, the following features are discussed: a level/flow cascade loop on the pump discharge to provide process control; a check valve on the discharge downstream of the control valve to prevent reverse flow when the pump is shut down; a fire safe motor operated valve (MOV) in case of seal leakage and fires; an interlock from the MOV to stop the pump if the valve is not fully opened; a low level interlock from the vessel to stop the pump if the vessel loses its liquid seal; a pressure gauge on the suction to indicate adequate NPSHA; a thermometer on the suction to indicate potentially high vapor pressure; a minimum flow recycle loop back to themore » vessel; a check valve on the recycle line to prevent reverse flow when the pump is shut down, especially when the fire valve is closed; and a pressure gauge on the pump discharge to indicate that the pump is working.« less\",\"PeriodicalId\":55043,\"journal\":{\"name\":\"Hydrocarbon Processing\",\"volume\":\"93 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/9781119267799.ch18\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hydrocarbon Processing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/9781119267799.ch18\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Chemical Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hydrocarbon Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/9781119267799.ch18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemical Engineering","Score":null,"Total":0}
引用次数: 13

摘要

有几种选择可以使泵的工作点与工艺相匹配,并仍然确保系统的可靠性。假设目前的泵足以满足工艺要求,那么将其修剪到所需的工作点的最佳方法是什么?有三个可能的位置放置阀门:在排放,吸入或使用回收阀。本文讨论了所有三种选择中的阀门放置。以泵从大型调压容器中抽取挥发性碳氢化合物为例,讨论了以下特征:泵排出的液位/流量级联回路提供过程控制;止回阀位于排放下游的控制阀上,防止泵关闭时倒流;在密封泄漏和火灾情况下,消防安全电机操作阀(MOV);如果阀门未完全打开,MOV的联锁装置可使泵停止;当容器失去液体密封时,从容器上连接的低位联锁装置可使泵停止;在吸盘上安装压力表,以显示有足够的NPSHA;吸盘上有温度计,显示潜在的高蒸汽压力;最小流量回收循环回more»容器;在循环管路上安装止回阀,防止泵关闭时,特别是在消防阀关闭时发生倒流;在泵流量上有一个压力表,表明泵正在工作。«少
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Controlling centrifugal pumps
Several options are available to match pump operating point to the process and still ensure system reliability. Assuming the pump is more than adequate for the process requirements at the moment, what is the best way to trim it to the desired operating point? There are three possible locations to place a valve: on the discharge, suction, or use a recycle valve. The paper discusses valve placement in all three options. Using the example of a pump drawing volatile hydrocarbons from a large surge vessel, the following features are discussed: a level/flow cascade loop on the pump discharge to provide process control; a check valve on the discharge downstream of the control valve to prevent reverse flow when the pump is shut down; a fire safe motor operated valve (MOV) in case of seal leakage and fires; an interlock from the MOV to stop the pump if the valve is not fully opened; a low level interlock from the vessel to stop the pump if the vessel loses its liquid seal; a pressure gauge on the suction to indicate adequate NPSHA; a thermometer on the suction to indicate potentially high vapor pressure; a minimum flow recycle loop back to themore » vessel; a check valve on the recycle line to prevent reverse flow when the pump is shut down, especially when the fire valve is closed; and a pressure gauge on the pump discharge to indicate that the pump is working.« less
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Hydrocarbon Processing
Hydrocarbon Processing 工程技术-工程:化工
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
期刊介绍: Information not localized
期刊最新文献
Inherently Safer Design Oil mist lubrication Words of praise Prevent system hydrate formation during sudden depressurization Reduce the impact of coke fines on delayed cokers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1