Jennifer J Labisch, G Philip Wiese, Karl Pflanz, John Linkhorst
{"title":"固定相的膜结构对慢病毒载体的立体排阻色谱(SXC)的影响。","authors":"Jennifer J Labisch, G Philip Wiese, Karl Pflanz, John Linkhorst","doi":"10.3390/membranes13100849","DOIUrl":null,"url":null,"abstract":"<p><p>For steric exclusion chromatography (SXC), hydrophilic stationary phases are used to capture the target molecule in the presence of polyethylene glycol. The influence of the structure and pore size of the stationary phase on the process requirements are not yet well understood. To better understand the SXC process, membranes with different pore sizes that served as a stationary phase were compared for the purification of lentiviral vectors (LVs). A design of experiments (DoE) was performed to assess the combined impact of PEG concentration and membrane pore size on the purification performance. A visualization experiment showed that the LVs were captured on the first membrane layer for a pore size up to 2.2 µm, and for a pore size larger than 2.2 µm, LVs were also partly found on the second and third membrane layers. Moreover, we could observe that increasing membrane pore size requires a higher PEG concentration to achieve comparable LV recoveries. Using five membrane layers as a stationary phase was sufficient to achieve good performance, supporting the visualized capture results. In conclusion, we could show that each stationary phase has its optimal PEG buffer compositions for SXC, depending on the membrane structure and pore size.</p>","PeriodicalId":18410,"journal":{"name":"Membranes","volume":"13 10","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2023-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10609039/pdf/","citationCount":"0","resultStr":"{\"title\":\"Impact of the Membrane Structure of the Stationary Phase on Steric Exclusion Chromatography (SXC) of Lentiviral Vectors.\",\"authors\":\"Jennifer J Labisch, G Philip Wiese, Karl Pflanz, John Linkhorst\",\"doi\":\"10.3390/membranes13100849\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>For steric exclusion chromatography (SXC), hydrophilic stationary phases are used to capture the target molecule in the presence of polyethylene glycol. The influence of the structure and pore size of the stationary phase on the process requirements are not yet well understood. To better understand the SXC process, membranes with different pore sizes that served as a stationary phase were compared for the purification of lentiviral vectors (LVs). A design of experiments (DoE) was performed to assess the combined impact of PEG concentration and membrane pore size on the purification performance. A visualization experiment showed that the LVs were captured on the first membrane layer for a pore size up to 2.2 µm, and for a pore size larger than 2.2 µm, LVs were also partly found on the second and third membrane layers. Moreover, we could observe that increasing membrane pore size requires a higher PEG concentration to achieve comparable LV recoveries. Using five membrane layers as a stationary phase was sufficient to achieve good performance, supporting the visualized capture results. In conclusion, we could show that each stationary phase has its optimal PEG buffer compositions for SXC, depending on the membrane structure and pore size.</p>\",\"PeriodicalId\":18410,\"journal\":{\"name\":\"Membranes\",\"volume\":\"13 10\",\"pages\":\"\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2023-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10609039/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Membranes\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/membranes13100849\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Membranes","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/membranes13100849","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
Impact of the Membrane Structure of the Stationary Phase on Steric Exclusion Chromatography (SXC) of Lentiviral Vectors.
For steric exclusion chromatography (SXC), hydrophilic stationary phases are used to capture the target molecule in the presence of polyethylene glycol. The influence of the structure and pore size of the stationary phase on the process requirements are not yet well understood. To better understand the SXC process, membranes with different pore sizes that served as a stationary phase were compared for the purification of lentiviral vectors (LVs). A design of experiments (DoE) was performed to assess the combined impact of PEG concentration and membrane pore size on the purification performance. A visualization experiment showed that the LVs were captured on the first membrane layer for a pore size up to 2.2 µm, and for a pore size larger than 2.2 µm, LVs were also partly found on the second and third membrane layers. Moreover, we could observe that increasing membrane pore size requires a higher PEG concentration to achieve comparable LV recoveries. Using five membrane layers as a stationary phase was sufficient to achieve good performance, supporting the visualized capture results. In conclusion, we could show that each stationary phase has its optimal PEG buffer compositions for SXC, depending on the membrane structure and pore size.
MembranesChemical Engineering-Filtration and Separation
CiteScore
6.10
自引率
16.70%
发文量
1071
审稿时长
11 weeks
期刊介绍:
Membranes (ISSN 2077-0375) is an international, peer-reviewed open access journal of separation science and technology. It publishes reviews, research articles, communications and technical notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. Full experimental and/or methodical details must be provided.