{"title":"荧光标记探针免疫层析同时定量测定多种分析物","authors":"D. Jeong, E. Choi","doi":"10.1080/12265071.2003.9647688","DOIUrl":null,"url":null,"abstract":"Immunoassays have become indispensable tools and achieved great importance in scientific and medical research. However, typical immunoassays are time‐consuming and use complex, multi‐step procedures. In this study, we introduce a new immunoassay system for the quantification of several analytes at a time without any washing steps. It is comprised of a detector solution with fluorescence‐labeled antibodies and a test strip with immobilized capture antibodies. Using a micro‐array scanner, the antigen‐anti body complex was quantitatively determined by measuring the intensities of fluorescence on the capture lines or dots of nitrocellulose membrane. This method demonstrated its rapid quantitative determination of analytes without many processing steps as well as specific identification of multiple analytes in biological specimens.","PeriodicalId":85060,"journal":{"name":"Korean journal of biological sciences","volume":"7 1","pages":"89 - 92"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/12265071.2003.9647688","citationCount":"5","resultStr":"{\"title\":\"Simultaneous quantitative determination of multiple analytes with fluorescence‐tagged probes by Immunochromatography\",\"authors\":\"D. Jeong, E. Choi\",\"doi\":\"10.1080/12265071.2003.9647688\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Immunoassays have become indispensable tools and achieved great importance in scientific and medical research. However, typical immunoassays are time‐consuming and use complex, multi‐step procedures. In this study, we introduce a new immunoassay system for the quantification of several analytes at a time without any washing steps. It is comprised of a detector solution with fluorescence‐labeled antibodies and a test strip with immobilized capture antibodies. Using a micro‐array scanner, the antigen‐anti body complex was quantitatively determined by measuring the intensities of fluorescence on the capture lines or dots of nitrocellulose membrane. This method demonstrated its rapid quantitative determination of analytes without many processing steps as well as specific identification of multiple analytes in biological specimens.\",\"PeriodicalId\":85060,\"journal\":{\"name\":\"Korean journal of biological sciences\",\"volume\":\"7 1\",\"pages\":\"89 - 92\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/12265071.2003.9647688\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean journal of biological sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/12265071.2003.9647688\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean journal of biological sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/12265071.2003.9647688","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Simultaneous quantitative determination of multiple analytes with fluorescence‐tagged probes by Immunochromatography
Immunoassays have become indispensable tools and achieved great importance in scientific and medical research. However, typical immunoassays are time‐consuming and use complex, multi‐step procedures. In this study, we introduce a new immunoassay system for the quantification of several analytes at a time without any washing steps. It is comprised of a detector solution with fluorescence‐labeled antibodies and a test strip with immobilized capture antibodies. Using a micro‐array scanner, the antigen‐anti body complex was quantitatively determined by measuring the intensities of fluorescence on the capture lines or dots of nitrocellulose membrane. This method demonstrated its rapid quantitative determination of analytes without many processing steps as well as specific identification of multiple analytes in biological specimens.