T. Karppinen, A. Redondas, R. García, K. Lakkala, C. T. McElroy, E. Kyrö
{"title":"单色布鲁尔分光光度计臭氧检索中杂散光影响的补偿","authors":"T. Karppinen, A. Redondas, R. García, K. Lakkala, C. T. McElroy, E. Kyrö","doi":"10.1080/07055900.2013.871499","DOIUrl":null,"url":null,"abstract":"Abstract Spectrometers are designed to isolate particular wavebands and suppress light from wavelengths outside the band of interest. However, a small amount of undesired light will always enter the detector, not through the designed optical path, but through random scattering from the instrument optical components, housing, and dust particles. Every spectrophotometer has stray light coming from outside the nominal measurement waveband. For Dobson spectrophotometers and single monochromator Brewer spectrophotometers, which are basic instruments in the World Meteorological Organization (WMO) ozone and ultraviolet (UV) monitoring network, the error introduced by stray light is substantial when the ozone slant path becomes very large because of high solar zenith angles and a thick ozone layer. These are common conditions during Arctic spring. To study the issue, a long ozone slant path Intercomparison/Calibration campaign for Nordic Brewers and Dobsons was held at Sodankylä 8–24 March 2011 and a follow-up campaign to extend calibrations to shorter ozone slant paths took place at Izaña observatory, Tenerife, between 28 October and 18 November 2011. These campaigns were part of the Committee on Earth Observation Satellites (CEOS) Intercalibration of Ground-based Spectrometers and Lidars project funded by the European Space Agency (ESA), intended to permit the homogenization of ozone data from the European ozone ground-truthing network. During the active intercomparison periods, measurements were taken only when good conditions for sun or moon observations existed. Laboratory measurements using calibration lamps and helium-cadmium (HeCd) lasers were an essential part of both campaigns. The campaigns produced a high-quality database of total ozone and UV measurements and an accurate, up-to-date calibration and characterization of participating Brewers and Dobsons against the European standard instruments from the Regional Dobson Calibration Centre-Europe (RDCC-E) and the Regional Brewer Calibration Centre-Europe (RBCC-E). In the present work we focus on single monochromator Brewers and present a physics-based method to compensate for the stray-light effects in ozone retrieval using laboratory characterizations and radiative transfer modelling. The method was tested with independent data from the campaign.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/07055900.2013.871499","citationCount":"29","resultStr":"{\"title\":\"Compensating for the Effects of Stray Light in Single-Monochromator Brewer Spectrophotometer Ozone Retrieval\",\"authors\":\"T. Karppinen, A. Redondas, R. García, K. Lakkala, C. T. McElroy, E. Kyrö\",\"doi\":\"10.1080/07055900.2013.871499\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Spectrometers are designed to isolate particular wavebands and suppress light from wavelengths outside the band of interest. However, a small amount of undesired light will always enter the detector, not through the designed optical path, but through random scattering from the instrument optical components, housing, and dust particles. Every spectrophotometer has stray light coming from outside the nominal measurement waveband. For Dobson spectrophotometers and single monochromator Brewer spectrophotometers, which are basic instruments in the World Meteorological Organization (WMO) ozone and ultraviolet (UV) monitoring network, the error introduced by stray light is substantial when the ozone slant path becomes very large because of high solar zenith angles and a thick ozone layer. These are common conditions during Arctic spring. To study the issue, a long ozone slant path Intercomparison/Calibration campaign for Nordic Brewers and Dobsons was held at Sodankylä 8–24 March 2011 and a follow-up campaign to extend calibrations to shorter ozone slant paths took place at Izaña observatory, Tenerife, between 28 October and 18 November 2011. These campaigns were part of the Committee on Earth Observation Satellites (CEOS) Intercalibration of Ground-based Spectrometers and Lidars project funded by the European Space Agency (ESA), intended to permit the homogenization of ozone data from the European ozone ground-truthing network. During the active intercomparison periods, measurements were taken only when good conditions for sun or moon observations existed. Laboratory measurements using calibration lamps and helium-cadmium (HeCd) lasers were an essential part of both campaigns. The campaigns produced a high-quality database of total ozone and UV measurements and an accurate, up-to-date calibration and characterization of participating Brewers and Dobsons against the European standard instruments from the Regional Dobson Calibration Centre-Europe (RDCC-E) and the Regional Brewer Calibration Centre-Europe (RBCC-E). In the present work we focus on single monochromator Brewers and present a physics-based method to compensate for the stray-light effects in ozone retrieval using laboratory characterizations and radiative transfer modelling. The method was tested with independent data from the campaign.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2015-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/07055900.2013.871499\",\"citationCount\":\"29\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.1080/07055900.2013.871499\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1080/07055900.2013.871499","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Compensating for the Effects of Stray Light in Single-Monochromator Brewer Spectrophotometer Ozone Retrieval
Abstract Spectrometers are designed to isolate particular wavebands and suppress light from wavelengths outside the band of interest. However, a small amount of undesired light will always enter the detector, not through the designed optical path, but through random scattering from the instrument optical components, housing, and dust particles. Every spectrophotometer has stray light coming from outside the nominal measurement waveband. For Dobson spectrophotometers and single monochromator Brewer spectrophotometers, which are basic instruments in the World Meteorological Organization (WMO) ozone and ultraviolet (UV) monitoring network, the error introduced by stray light is substantial when the ozone slant path becomes very large because of high solar zenith angles and a thick ozone layer. These are common conditions during Arctic spring. To study the issue, a long ozone slant path Intercomparison/Calibration campaign for Nordic Brewers and Dobsons was held at Sodankylä 8–24 March 2011 and a follow-up campaign to extend calibrations to shorter ozone slant paths took place at Izaña observatory, Tenerife, between 28 October and 18 November 2011. These campaigns were part of the Committee on Earth Observation Satellites (CEOS) Intercalibration of Ground-based Spectrometers and Lidars project funded by the European Space Agency (ESA), intended to permit the homogenization of ozone data from the European ozone ground-truthing network. During the active intercomparison periods, measurements were taken only when good conditions for sun or moon observations existed. Laboratory measurements using calibration lamps and helium-cadmium (HeCd) lasers were an essential part of both campaigns. The campaigns produced a high-quality database of total ozone and UV measurements and an accurate, up-to-date calibration and characterization of participating Brewers and Dobsons against the European standard instruments from the Regional Dobson Calibration Centre-Europe (RDCC-E) and the Regional Brewer Calibration Centre-Europe (RBCC-E). In the present work we focus on single monochromator Brewers and present a physics-based method to compensate for the stray-light effects in ozone retrieval using laboratory characterizations and radiative transfer modelling. The method was tested with independent data from the campaign.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.