{"title":"高频电容器损耗电导的直接测量","authors":"M. Boella","doi":"10.1109/JRPROC.1938.228310","DOIUrl":null,"url":null,"abstract":"A method of measuring the losses of a variable air condenser at high frequencies is described in which the condenser under test and the standard are connected in series as part of a tuned circuit. A radio-frequency voltage of resonant frequency is impressed on this circuit for a stated value of the standard. The unknown is then removed and the standard adjusted to resonance. The voltage across the tuned circuit is readjusted to its initial value by placing a conductance across the standard. The design of the standard condenser requires special considerations which are discussed. A self-biasing valve voltmeter, which is not critical to variations in power-supply voltage, is used. The results of measurements on several specimen condensers are given. A method of extending the measurements to higher frequencies is shown.","PeriodicalId":54574,"journal":{"name":"Proceedings of the Institute of Radio Engineers","volume":"26 1","pages":"421-432"},"PeriodicalIF":0.0000,"publicationDate":"1938-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/JRPROC.1938.228310","citationCount":"0","resultStr":"{\"title\":\"Direct Measurement of the Loss Conductance of Condensers at High Frequencies\",\"authors\":\"M. Boella\",\"doi\":\"10.1109/JRPROC.1938.228310\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method of measuring the losses of a variable air condenser at high frequencies is described in which the condenser under test and the standard are connected in series as part of a tuned circuit. A radio-frequency voltage of resonant frequency is impressed on this circuit for a stated value of the standard. The unknown is then removed and the standard adjusted to resonance. The voltage across the tuned circuit is readjusted to its initial value by placing a conductance across the standard. The design of the standard condenser requires special considerations which are discussed. A self-biasing valve voltmeter, which is not critical to variations in power-supply voltage, is used. The results of measurements on several specimen condensers are given. A method of extending the measurements to higher frequencies is shown.\",\"PeriodicalId\":54574,\"journal\":{\"name\":\"Proceedings of the Institute of Radio Engineers\",\"volume\":\"26 1\",\"pages\":\"421-432\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1938-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/JRPROC.1938.228310\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institute of Radio Engineers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/JRPROC.1938.228310\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institute of Radio Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/JRPROC.1938.228310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文描述了一种在高频下测量可变空气电容器损耗的方法,该方法将被测电容器和标准电容器串联起来,作为调谐电路的一部分。谐振频率的射频电压按规定的标准值压在电路上。然后移除未知项,并将标准调整为共振。通过在标准上放置电导,将调谐电路上的电压重新调整到其初始值。标准冷凝器的设计需要特别考虑,我们将对此进行讨论。使用自偏置阀电压表,它对电源电压的变化不重要。给出了对几个样品冷凝器的测量结果。给出了一种将测量扩展到更高频率的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Direct Measurement of the Loss Conductance of Condensers at High Frequencies
A method of measuring the losses of a variable air condenser at high frequencies is described in which the condenser under test and the standard are connected in series as part of a tuned circuit. A radio-frequency voltage of resonant frequency is impressed on this circuit for a stated value of the standard. The unknown is then removed and the standard adjusted to resonance. The voltage across the tuned circuit is readjusted to its initial value by placing a conductance across the standard. The design of the standard condenser requires special considerations which are discussed. A self-biasing valve voltmeter, which is not critical to variations in power-supply voltage, is used. The results of measurements on several specimen condensers are given. A method of extending the measurements to higher frequencies is shown.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Continuous Measurements of the Virtual Heights of the Ionosphere Performance Tests of Radio System of Landing Aids New Piezo Oscillations with Quartz Cylinders Cut along the Optical Axis Some Observations of Short Period Radio Fading Characteristics of Airplane Antennas for Radio Range Beacon Reception
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1