高效调制系统

R. Dome
{"title":"高效调制系统","authors":"R. Dome","doi":"10.1109/JRPROC.1938.228495","DOIUrl":null,"url":null,"abstract":"A descriptive and mathematical treatment is given of a means for obtaining modulated radio-frequency power with good conversion efficiency from the usual direct-current source. The method employed is to modify the load line on a saturated radio-frequency amplifier to take care of positive peaks and to grid modulate the amplifier for negative peaks. Load modification is accomplished by absorption and in this system the absorbed power is not dissipated in heat but is returned to the direct-current source for the power-amplifier tube and thereby reduces the drain from the supply. This results in direct-current-to-carrier conversion efficiencics in the order of 50 to 60 per cent when average tubes are used.","PeriodicalId":54574,"journal":{"name":"Proceedings of the Institute of Radio Engineers","volume":"26 1","pages":"963-982"},"PeriodicalIF":0.0000,"publicationDate":"1938-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/JRPROC.1938.228495","citationCount":"4","resultStr":"{\"title\":\"High-Efficiency Modulation System\",\"authors\":\"R. Dome\",\"doi\":\"10.1109/JRPROC.1938.228495\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A descriptive and mathematical treatment is given of a means for obtaining modulated radio-frequency power with good conversion efficiency from the usual direct-current source. The method employed is to modify the load line on a saturated radio-frequency amplifier to take care of positive peaks and to grid modulate the amplifier for negative peaks. Load modification is accomplished by absorption and in this system the absorbed power is not dissipated in heat but is returned to the direct-current source for the power-amplifier tube and thereby reduces the drain from the supply. This results in direct-current-to-carrier conversion efficiencics in the order of 50 to 60 per cent when average tubes are used.\",\"PeriodicalId\":54574,\"journal\":{\"name\":\"Proceedings of the Institute of Radio Engineers\",\"volume\":\"26 1\",\"pages\":\"963-982\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1938-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/JRPROC.1938.228495\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institute of Radio Engineers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/JRPROC.1938.228495\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institute of Radio Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/JRPROC.1938.228495","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

给出了一种从常用直流电源获得具有良好转换效率的调制射频功率的方法的描述和数学处理。所采用的方法是修改饱和射频放大器上的负载线以照顾正峰值,并对放大器的负峰值进行网格调制。负载调整是通过吸收来完成的,在这个系统中,吸收的功率不会以热量的形式消散,而是返回到功率放大器管的直流源,从而减少了电源的损耗。当使用普通电子管时,直流到载流子的转换效率为50%至60%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High-Efficiency Modulation System
A descriptive and mathematical treatment is given of a means for obtaining modulated radio-frequency power with good conversion efficiency from the usual direct-current source. The method employed is to modify the load line on a saturated radio-frequency amplifier to take care of positive peaks and to grid modulate the amplifier for negative peaks. Load modification is accomplished by absorption and in this system the absorbed power is not dissipated in heat but is returned to the direct-current source for the power-amplifier tube and thereby reduces the drain from the supply. This results in direct-current-to-carrier conversion efficiencics in the order of 50 to 60 per cent when average tubes are used.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Continuous Measurements of the Virtual Heights of the Ionosphere Performance Tests of Radio System of Landing Aids New Piezo Oscillations with Quartz Cylinders Cut along the Optical Axis Some Observations of Short Period Radio Fading Characteristics of Airplane Antennas for Radio Range Beacon Reception
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1