基于聚苯胺纳米纤维OFET的高灵敏度、低工作功率心脏肌钙蛋白生物传感器

IF 2.1 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Transactions on Nanotechnology Pub Date : 2023-09-07 DOI:10.1109/TNANO.2023.3312819
Amira Ali;Abdelsattar M. Sallam;M. Mohsen;Amal Kasry;Sameh O. Abdellatif
{"title":"基于聚苯胺纳米纤维OFET的高灵敏度、低工作功率心脏肌钙蛋白生物传感器","authors":"Amira Ali;Abdelsattar M. Sallam;M. Mohsen;Amal Kasry;Sameh O. Abdellatif","doi":"10.1109/TNANO.2023.3312819","DOIUrl":null,"url":null,"abstract":"Cardiovascular diseases (CVDs) are the leading cause of death worldwide, killing over 17 million people yearly. A key biomarker for identifying myocardial infarction (MI) is the regulatory protein Cardiovascular Troponin I (cTnI), released into the blood following heart muscle injury. Significant efforts have been made in recent years to develop highly sensitive biosensors for the detection of cTnI. Field effect transistors (FETs) in general and organic FETs (OFETs) in specific have shown computability in detecting such cordial protein. In this study, we provide a complete attempt to fabricate and characterize polyaniline nanofiber (PANI-NFs) OFET for biosensing applications. The FTIR spectrum of PANI-NFs is examined before and after pAbs immobilization. To study the biosensor performance parameters, the biomarker drain current is investigated against the cTnI biomarker concentrations. The proposed OFET recorded high sensitivity of 484 nA.(g/mL)\n<sup>−1</sup>\n, with a minimum detection limit (0.36 pg/mL) and power consumption varying from 7 μW to 11.4 μW. Finally, the biosensing repeatability was examined regarding variation in the P-FET device and the biasing conditions.","PeriodicalId":449,"journal":{"name":"IEEE Transactions on Nanotechnology","volume":"22 ","pages":"558-563"},"PeriodicalIF":2.1000,"publicationDate":"2023-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Highly Sensitive, Low Operating Power Cardiac Troponin Biosensor Using PANI Nanofiber OFET\",\"authors\":\"Amira Ali;Abdelsattar M. Sallam;M. Mohsen;Amal Kasry;Sameh O. Abdellatif\",\"doi\":\"10.1109/TNANO.2023.3312819\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cardiovascular diseases (CVDs) are the leading cause of death worldwide, killing over 17 million people yearly. A key biomarker for identifying myocardial infarction (MI) is the regulatory protein Cardiovascular Troponin I (cTnI), released into the blood following heart muscle injury. Significant efforts have been made in recent years to develop highly sensitive biosensors for the detection of cTnI. Field effect transistors (FETs) in general and organic FETs (OFETs) in specific have shown computability in detecting such cordial protein. In this study, we provide a complete attempt to fabricate and characterize polyaniline nanofiber (PANI-NFs) OFET for biosensing applications. The FTIR spectrum of PANI-NFs is examined before and after pAbs immobilization. To study the biosensor performance parameters, the biomarker drain current is investigated against the cTnI biomarker concentrations. The proposed OFET recorded high sensitivity of 484 nA.(g/mL)\\n<sup>−1</sup>\\n, with a minimum detection limit (0.36 pg/mL) and power consumption varying from 7 μW to 11.4 μW. Finally, the biosensing repeatability was examined regarding variation in the P-FET device and the biasing conditions.\",\"PeriodicalId\":449,\"journal\":{\"name\":\"IEEE Transactions on Nanotechnology\",\"volume\":\"22 \",\"pages\":\"558-563\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Nanotechnology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10243047/\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Nanotechnology","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10243047/","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

心血管疾病是世界范围内的主要死亡原因,每年造成1700多万人死亡。识别心肌梗死(MI)的关键生物标志物是调节蛋白心血管肌钙蛋白I (cTnI),在心肌损伤后释放到血液中。近年来,人们在开发高灵敏度的cTnI检测生物传感器方面做出了巨大的努力。一般的场效应晶体管(fet)和特定的有机场效应晶体管(ofet)在检测这类诚恳蛋白方面显示出可计算性。在这项研究中,我们为生物传感应用的聚苯胺纳米纤维(PANI-NFs) OFET的制备和表征提供了一个完整的尝试。研究了pAbs固定前后PANI-NFs的FTIR光谱。为了研究生物传感器的性能参数,研究了生物标志物漏极电流与cTnI生物标志物浓度的关系。该OFET的灵敏度为484 nA.(g/mL)−1,最低检测限为0.36 pg/mL,功耗为7 μW ~ 11.4 μW。最后,研究了P-FET器件和偏置条件的变化对生物传感重复性的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Highly Sensitive, Low Operating Power Cardiac Troponin Biosensor Using PANI Nanofiber OFET
Cardiovascular diseases (CVDs) are the leading cause of death worldwide, killing over 17 million people yearly. A key biomarker for identifying myocardial infarction (MI) is the regulatory protein Cardiovascular Troponin I (cTnI), released into the blood following heart muscle injury. Significant efforts have been made in recent years to develop highly sensitive biosensors for the detection of cTnI. Field effect transistors (FETs) in general and organic FETs (OFETs) in specific have shown computability in detecting such cordial protein. In this study, we provide a complete attempt to fabricate and characterize polyaniline nanofiber (PANI-NFs) OFET for biosensing applications. The FTIR spectrum of PANI-NFs is examined before and after pAbs immobilization. To study the biosensor performance parameters, the biomarker drain current is investigated against the cTnI biomarker concentrations. The proposed OFET recorded high sensitivity of 484 nA.(g/mL) −1 , with a minimum detection limit (0.36 pg/mL) and power consumption varying from 7 μW to 11.4 μW. Finally, the biosensing repeatability was examined regarding variation in the P-FET device and the biasing conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Nanotechnology
IEEE Transactions on Nanotechnology 工程技术-材料科学:综合
CiteScore
4.80
自引率
8.30%
发文量
74
审稿时长
8.3 months
期刊介绍: The IEEE Transactions on Nanotechnology is devoted to the publication of manuscripts of archival value in the general area of nanotechnology, which is rapidly emerging as one of the fastest growing and most promising new technological developments for the next generation and beyond.
期刊最新文献
High-Speed and Area-Efficient Serial IMPLY-Based Approximate Subtractor and Comparator for Image Processing and Neural Networks Design of a Graphene Based Terahertz Perfect Metamaterial Absorber With Multiple Sensing Performance Impact of Electron and Hole Trap Profiles in BE-TOX on Retention Characteristics of 3D NAND Flash Memory Full 3-D Monte Carlo Simulation of Coupled Electron-Phonon Transport: Self-Heating in a Nanoscale FinFET Experimental Investigations and Characterization of Surfactant Activated Mixed Metal Oxide (MMO) Nanomaterial
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1