体外盂肱骨试验装置的研制

D. Hughes
{"title":"体外盂肱骨试验装置的研制","authors":"D. Hughes","doi":"10.1504/IJECB.2012.049808","DOIUrl":null,"url":null,"abstract":"Until recently the accurate measurement of contact loads acting in the glenohumeral joint have been difficult to calculate and define. Now, contact forces and moments are measured in vivo using telemeterised shoulder implants. This method limits testing opportunities so a dynamic shoulder testing apparatus has been developed to examine glenohumeral joint motion and forces. This in vitro study evaluated the accuracy of forces generated in the glenohumeral joint using an instrumented prosthetic implant. Forces were applied to cables to simulate loading of the supraspinatus, subscapularis, infraspinatus/teres minor, long head biceps and anterior, middle, and posterior deltoid muscles. \n \nThe test rig reproduces the 6DoF of the glenohumeral joint and accurately recreates the contact forces measured in vivo. This test rig will allow many more tests to be simulated including comparison of fixation methods and high impact injuries.","PeriodicalId":90184,"journal":{"name":"International journal of experimental and computational biomechanics","volume":"49 1","pages":"96"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1504/IJECB.2012.049808","citationCount":"1","resultStr":"{\"title\":\"The development of an in vitro glenohumeral testing rig\",\"authors\":\"D. Hughes\",\"doi\":\"10.1504/IJECB.2012.049808\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Until recently the accurate measurement of contact loads acting in the glenohumeral joint have been difficult to calculate and define. Now, contact forces and moments are measured in vivo using telemeterised shoulder implants. This method limits testing opportunities so a dynamic shoulder testing apparatus has been developed to examine glenohumeral joint motion and forces. This in vitro study evaluated the accuracy of forces generated in the glenohumeral joint using an instrumented prosthetic implant. Forces were applied to cables to simulate loading of the supraspinatus, subscapularis, infraspinatus/teres minor, long head biceps and anterior, middle, and posterior deltoid muscles. \\n \\nThe test rig reproduces the 6DoF of the glenohumeral joint and accurately recreates the contact forces measured in vivo. This test rig will allow many more tests to be simulated including comparison of fixation methods and high impact injuries.\",\"PeriodicalId\":90184,\"journal\":{\"name\":\"International journal of experimental and computational biomechanics\",\"volume\":\"49 1\",\"pages\":\"96\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1504/IJECB.2012.049808\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of experimental and computational biomechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1504/IJECB.2012.049808\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of experimental and computational biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJECB.2012.049808","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

直到最近,准确测量作用于盂肱关节的接触载荷一直难以计算和定义。现在,接触力和力矩是使用远程测量肩部植入物在体内测量的。这种方法限制了测试机会,因此开发了一种动态肩部测试设备来检查肩关节运动和力。这项体外研究评估了使用固定式假体植入物在盂肱关节产生的力的准确性。对缆绳施加力以模拟冈上肌、肩胛下肌、冈下肌/小圆肌、长头二头肌和前、中、后三角肌的负荷。该试验台再现了关节的6DoF,准确再现了体内测量的接触力。该测试平台将允许模拟更多的测试,包括固定方法和高冲击损伤的比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The development of an in vitro glenohumeral testing rig
Until recently the accurate measurement of contact loads acting in the glenohumeral joint have been difficult to calculate and define. Now, contact forces and moments are measured in vivo using telemeterised shoulder implants. This method limits testing opportunities so a dynamic shoulder testing apparatus has been developed to examine glenohumeral joint motion and forces. This in vitro study evaluated the accuracy of forces generated in the glenohumeral joint using an instrumented prosthetic implant. Forces were applied to cables to simulate loading of the supraspinatus, subscapularis, infraspinatus/teres minor, long head biceps and anterior, middle, and posterior deltoid muscles. The test rig reproduces the 6DoF of the glenohumeral joint and accurately recreates the contact forces measured in vivo. This test rig will allow many more tests to be simulated including comparison of fixation methods and high impact injuries.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Model for the Roles of Actin and Myosin in Adjustable Preload Tension and Acute Length Adaption Finite element analysis for knee implants with suitable material combinations Non-Newtonian blood flow and coupled blood-wall oxygen mass transport in a 180° curved artery Effects of athletic footwear on plantar force during rope skipping Analysis on the gait of lower limbs in different walking speed
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1