{"title":"工业膜的理化性质与气液膜接触器CO2吸收性能的关系","authors":"Yilin Xu, C. Malde, Rui Wang","doi":"10.22079/JMSR.2019.107096.1262","DOIUrl":null,"url":null,"abstract":"The gas-liquid membrane contactor (GLMC) is a promising alternative gas absorption/desorption configuration for effective carbon dioxide (CO2 ) capture. The physicochemical properties of membranes may synergistically affect GLMC performances, especially during the long-term operations. In this work, commercial polypropylene (PP) and polyvinylidene fluoride (PVDF) hollow fiber (HF) membranes were applied to explore the effects of their physicochemical properties on long-term CO2 absorption performances in a bench-scale GLMC rig. PP membranes with pore size of 19 nm, thickness of 0.046 mm, and porosity of 58% achieved high CO2 flux when feeding pure CO2 (5.4 and 24.4×10-3 mol/m2 .s using absorbents of water and 1M monoethanolamine (MEA), respectively) whereas PVDF membranes with pore size of 24 nm, thickness of 0.343 mm, and porosity of 84% presented a good CO2 separation performance from the simulated biogas using 1M MEA (6.8×10-3 mol/m2 .s and 99.9% CH4 recovery). When using water as absorbent, the coupled phenomena of membrane wetting and fouling restricted CO2 transport and resulted in continuous flux loss during the long-term operations. When using MEA as absorbent, both PP and PVDF membranes suffered dramatic flux decline. A series of membrane characterization tests revealed that the morphology, pore size, hydrophobicity, and stability of selected commercial membranes were greatly affected by MEA attack during long-term operations. Therefore, the selection criterion of microporous membranes for high-efficiency and long-term stable CO2 absorption in GLMC processes was proposed. It is envisioned that this study can shed light on improving existing membrane fabrication procedures and the application of novel membrane surface modification techniques to facilitate practical applications of the GLMC technology.","PeriodicalId":16427,"journal":{"name":"Journal of Membrane Science and Research","volume":"6 1","pages":"30-39"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Correlating Physicochemical Properties of Commercial Membranes with CO2 Absorption Performance in Gas-Liquid Membrane Contactor\",\"authors\":\"Yilin Xu, C. Malde, Rui Wang\",\"doi\":\"10.22079/JMSR.2019.107096.1262\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The gas-liquid membrane contactor (GLMC) is a promising alternative gas absorption/desorption configuration for effective carbon dioxide (CO2 ) capture. The physicochemical properties of membranes may synergistically affect GLMC performances, especially during the long-term operations. In this work, commercial polypropylene (PP) and polyvinylidene fluoride (PVDF) hollow fiber (HF) membranes were applied to explore the effects of their physicochemical properties on long-term CO2 absorption performances in a bench-scale GLMC rig. PP membranes with pore size of 19 nm, thickness of 0.046 mm, and porosity of 58% achieved high CO2 flux when feeding pure CO2 (5.4 and 24.4×10-3 mol/m2 .s using absorbents of water and 1M monoethanolamine (MEA), respectively) whereas PVDF membranes with pore size of 24 nm, thickness of 0.343 mm, and porosity of 84% presented a good CO2 separation performance from the simulated biogas using 1M MEA (6.8×10-3 mol/m2 .s and 99.9% CH4 recovery). When using water as absorbent, the coupled phenomena of membrane wetting and fouling restricted CO2 transport and resulted in continuous flux loss during the long-term operations. When using MEA as absorbent, both PP and PVDF membranes suffered dramatic flux decline. A series of membrane characterization tests revealed that the morphology, pore size, hydrophobicity, and stability of selected commercial membranes were greatly affected by MEA attack during long-term operations. Therefore, the selection criterion of microporous membranes for high-efficiency and long-term stable CO2 absorption in GLMC processes was proposed. It is envisioned that this study can shed light on improving existing membrane fabrication procedures and the application of novel membrane surface modification techniques to facilitate practical applications of the GLMC technology.\",\"PeriodicalId\":16427,\"journal\":{\"name\":\"Journal of Membrane Science and Research\",\"volume\":\"6 1\",\"pages\":\"30-39\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Membrane Science and Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22079/JMSR.2019.107096.1262\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Materials Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Membrane Science and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22079/JMSR.2019.107096.1262","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Materials Science","Score":null,"Total":0}
Correlating Physicochemical Properties of Commercial Membranes with CO2 Absorption Performance in Gas-Liquid Membrane Contactor
The gas-liquid membrane contactor (GLMC) is a promising alternative gas absorption/desorption configuration for effective carbon dioxide (CO2 ) capture. The physicochemical properties of membranes may synergistically affect GLMC performances, especially during the long-term operations. In this work, commercial polypropylene (PP) and polyvinylidene fluoride (PVDF) hollow fiber (HF) membranes were applied to explore the effects of their physicochemical properties on long-term CO2 absorption performances in a bench-scale GLMC rig. PP membranes with pore size of 19 nm, thickness of 0.046 mm, and porosity of 58% achieved high CO2 flux when feeding pure CO2 (5.4 and 24.4×10-3 mol/m2 .s using absorbents of water and 1M monoethanolamine (MEA), respectively) whereas PVDF membranes with pore size of 24 nm, thickness of 0.343 mm, and porosity of 84% presented a good CO2 separation performance from the simulated biogas using 1M MEA (6.8×10-3 mol/m2 .s and 99.9% CH4 recovery). When using water as absorbent, the coupled phenomena of membrane wetting and fouling restricted CO2 transport and resulted in continuous flux loss during the long-term operations. When using MEA as absorbent, both PP and PVDF membranes suffered dramatic flux decline. A series of membrane characterization tests revealed that the morphology, pore size, hydrophobicity, and stability of selected commercial membranes were greatly affected by MEA attack during long-term operations. Therefore, the selection criterion of microporous membranes for high-efficiency and long-term stable CO2 absorption in GLMC processes was proposed. It is envisioned that this study can shed light on improving existing membrane fabrication procedures and the application of novel membrane surface modification techniques to facilitate practical applications of the GLMC technology.
期刊介绍:
The Journal of Membrane Science and Research (JMSR) is an Open Access journal with Free of Charge publication policy, which provides a focal point for academic and industrial chemical and polymer engineers, chemists, materials scientists, and membranologists working on both membranes and membrane processes, particularly for four major sectors, including Energy, Water, Environment and Food. The journal publishes original research and reviews on membranes (organic, inorganic, liquid and etc.) and membrane processes (MF, UF, NF, RO, ED, Dialysis, MD, PV, CDI, FO, GP, VP and etc.), membrane formation/structure/performance, fouling, module/process design, and processes/applications in various areas. Primary emphasis is on structure, function, and performance of essentially non-biological membranes.