应用下腔静脉超声检查和光谱生物阻抗评估血液透析患者血容量状况

IF 0.2 4区 医学 Q4 MEDICINE, GENERAL & INTERNAL Vojnosanitetski pregled Pub Date : 2022-01-01 DOI:10.2298/vsp200513131l
T. Lazarevic, D. Petrovic, Ljiljana Novkovic, Katarina M. Janicijevic, Mirjana Janićijević-Petrović, A. Vujic, B. Ljujic, M. Sazdanović, Zorana Kovačević
{"title":"应用下腔静脉超声检查和光谱生物阻抗评估血液透析患者血容量状况","authors":"T. Lazarevic, D. Petrovic, Ljiljana Novkovic, Katarina M. Janicijevic, Mirjana Janićijević-Petrović, A. Vujic, B. Ljujic, M. Sazdanović, Zorana Kovačević","doi":"10.2298/vsp200513131l","DOIUrl":null,"url":null,"abstract":"Background/Aim. Hypervolemia is an important risk factor for the development of cardiovascular morbidity and mortality in patients treated with regular hemodialysis. There is still no reliable method for assessing the status of volemia in these patients. The aim of the study was to assess the status of volemia in patients treated with regular hemodialysis by measuring the parameters of the inferior vena cava (IVC) and bioimpedance. Methods. The effect of hemodialysis treatment on ultrasound parameters of the IVC, as well as on the parameters measured by bioimpedance, was examined before and after hemodialysis. The values of the N-terminal prohormone of brain natriuretic peptide (NT-proBNP) were measured both before and after hemodialysis. Forty-five patients were involved in this non-interventional cross-section study, including the patients treated with standard bicarbonate dialysis. According to the interdialytic yield, the patients were divided into three groups: I (up to 2,000 mL), II (2,000?3,000 mL), and III (over 3,000 mL). Results. The values of the IVC parameters and the parameters measured with bioimpedance were significantly lower after treatment with hemodialysis (p < 0.005). The third group of patients had a significantly higher total fluid volume in the body com-pared to the group I, as well as a significantly greater volume of extracellular fluid (p < 0.005). The significantly lower values of NT-proBNP in all groups (p < 0.005) were detected after hemodialysis. After treatment with hemodialysis, a positive correlation was observed between the concentration of NT-proBNP in the serum and the extracellular/intracellular water ratio. However, the correlation between NT-proBNP concentration and total fluid measured by bioimpedance spectroscopy did not reach statistical significance. Conclusion. Measurement of the IVC ultrasound parameters and volemia parameters using bioimpedance significantly contributes to the assessment of the status of volemia. Nevertheless, it cannot be used as a separate parameter, only in combination with all other methods.","PeriodicalId":23531,"journal":{"name":"Vojnosanitetski pregled","volume":"1 1","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of volemia status using ultrasound examination of the inferior vena cava and spectroscopic bioimpendance in hemodialysis patients\",\"authors\":\"T. Lazarevic, D. Petrovic, Ljiljana Novkovic, Katarina M. Janicijevic, Mirjana Janićijević-Petrović, A. Vujic, B. Ljujic, M. Sazdanović, Zorana Kovačević\",\"doi\":\"10.2298/vsp200513131l\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background/Aim. Hypervolemia is an important risk factor for the development of cardiovascular morbidity and mortality in patients treated with regular hemodialysis. There is still no reliable method for assessing the status of volemia in these patients. The aim of the study was to assess the status of volemia in patients treated with regular hemodialysis by measuring the parameters of the inferior vena cava (IVC) and bioimpedance. Methods. The effect of hemodialysis treatment on ultrasound parameters of the IVC, as well as on the parameters measured by bioimpedance, was examined before and after hemodialysis. The values of the N-terminal prohormone of brain natriuretic peptide (NT-proBNP) were measured both before and after hemodialysis. Forty-five patients were involved in this non-interventional cross-section study, including the patients treated with standard bicarbonate dialysis. According to the interdialytic yield, the patients were divided into three groups: I (up to 2,000 mL), II (2,000?3,000 mL), and III (over 3,000 mL). Results. The values of the IVC parameters and the parameters measured with bioimpedance were significantly lower after treatment with hemodialysis (p < 0.005). The third group of patients had a significantly higher total fluid volume in the body com-pared to the group I, as well as a significantly greater volume of extracellular fluid (p < 0.005). The significantly lower values of NT-proBNP in all groups (p < 0.005) were detected after hemodialysis. After treatment with hemodialysis, a positive correlation was observed between the concentration of NT-proBNP in the serum and the extracellular/intracellular water ratio. However, the correlation between NT-proBNP concentration and total fluid measured by bioimpedance spectroscopy did not reach statistical significance. Conclusion. Measurement of the IVC ultrasound parameters and volemia parameters using bioimpedance significantly contributes to the assessment of the status of volemia. Nevertheless, it cannot be used as a separate parameter, only in combination with all other methods.\",\"PeriodicalId\":23531,\"journal\":{\"name\":\"Vojnosanitetski pregled\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vojnosanitetski pregled\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2298/vsp200513131l\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vojnosanitetski pregled","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2298/vsp200513131l","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的。在接受常规血液透析治疗的患者中,高血容量是心血管发病率和死亡率发展的重要危险因素。目前还没有可靠的方法来评估这些患者的血容量状况。该研究的目的是通过测量下腔静脉(IVC)和生物阻抗的参数来评估定期血液透析患者的血容量状况。方法。观察血液透析治疗前后对下腔静脉超声参数及生物阻抗测量参数的影响。测定血液透析前后脑利钠肽n端原激素(NT-proBNP)水平。45例患者参与了这项非介入性横断面研究,包括接受标准碳酸氢盐透析治疗的患者。根据透析间隙量将患者分为3组:I组(最多2,000 mL), II组(2,000?3000毫升)和III(超过3000毫升)。结果。血液透析治疗后IVC参数和生物阻抗测量参数值均显著降低(p < 0.005)。与第一组相比,第三组患者体内总液体体积显著增加,细胞外液体积显著增加(p < 0.005)。血液透析后各组NT-proBNP均显著降低(p < 0.005)。血液透析治疗后,血清NT-proBNP浓度与细胞外/细胞内水比呈正相关。然而,NT-proBNP浓度与生物阻抗谱测定的总流体之间的相关性无统计学意义。结论。使用生物阻抗测量下腔静脉超声参数和容量参数对评估容量状态有重要意义。但是,它不能作为单独的参数使用,只能与所有其他方法结合使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of volemia status using ultrasound examination of the inferior vena cava and spectroscopic bioimpendance in hemodialysis patients
Background/Aim. Hypervolemia is an important risk factor for the development of cardiovascular morbidity and mortality in patients treated with regular hemodialysis. There is still no reliable method for assessing the status of volemia in these patients. The aim of the study was to assess the status of volemia in patients treated with regular hemodialysis by measuring the parameters of the inferior vena cava (IVC) and bioimpedance. Methods. The effect of hemodialysis treatment on ultrasound parameters of the IVC, as well as on the parameters measured by bioimpedance, was examined before and after hemodialysis. The values of the N-terminal prohormone of brain natriuretic peptide (NT-proBNP) were measured both before and after hemodialysis. Forty-five patients were involved in this non-interventional cross-section study, including the patients treated with standard bicarbonate dialysis. According to the interdialytic yield, the patients were divided into three groups: I (up to 2,000 mL), II (2,000?3,000 mL), and III (over 3,000 mL). Results. The values of the IVC parameters and the parameters measured with bioimpedance were significantly lower after treatment with hemodialysis (p < 0.005). The third group of patients had a significantly higher total fluid volume in the body com-pared to the group I, as well as a significantly greater volume of extracellular fluid (p < 0.005). The significantly lower values of NT-proBNP in all groups (p < 0.005) were detected after hemodialysis. After treatment with hemodialysis, a positive correlation was observed between the concentration of NT-proBNP in the serum and the extracellular/intracellular water ratio. However, the correlation between NT-proBNP concentration and total fluid measured by bioimpedance spectroscopy did not reach statistical significance. Conclusion. Measurement of the IVC ultrasound parameters and volemia parameters using bioimpedance significantly contributes to the assessment of the status of volemia. Nevertheless, it cannot be used as a separate parameter, only in combination with all other methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Vojnosanitetski pregled
Vojnosanitetski pregled MEDICINE, GENERAL & INTERNAL-
CiteScore
0.50
自引率
0.00%
发文量
161
审稿时长
3-8 weeks
期刊介绍: Vojnosanitetski pregled (VSP) is a leading medical journal of physicians and pharmacists of the Serbian Army. The Journal is published monthly.
期刊最新文献
Corrigendum to Management of osteochondritis dissecans (OCD) of the elbow trochlea in the adolescent population: A systematic review. Neurophysiological confirmation of phrenic nerve affection in patient with dyspnea and herpes zoster Acute coronary syndrome in a young patient with ECG presentation of acute inferior myocardial infarction and acute thrombosis of left main stem coronary artery Gadolinium deposition in the brain of patients with relapsing-remitting multiple sclerosis after 10 years of follow-up Prevalence of computer vision syndrome in computer users: A systematic review and meta-analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1