{"title":"静态顶空气相色谱-质谱-模型溶液中苯、甲苯、乙苯、二甲苯和苯乙烯测定条件的优化","authors":"Ozlem Yilmazcan, E. Özer, B. Izgi, Ş. Gucer","doi":"10.5053/EKOLOJI.2013.899","DOIUrl":null,"url":null,"abstract":"A method was developed and validated for the analysis of benzene, toluene, ethylbenzene, xylene (BTEX), and styrene in sea water samples using gas chromatography-mass spectrometry (GC-MS) with static headspace extraction. To carefully characterize the performance of this method, several factors affecting the parameters were studied in detail, such as the heating procedure, loop filling time, equilibrium temperature, the sample dilution ratio, equilibrium, and injection times. The optimized conditions are as follows: 1)the heating procedure, 50°C for 4 min, then increased to 170°C at 15°C min-1, 2) equilibrium temperature, 60°C, 3) equilibrium time, 5 min, and 4) injection time 0.5 min. Under the optimized conditions, the linear equations were obtained in the concentration range of 10 - 50 μg L-1 with good correlation coefficient values. The limits of detection were 1.8 - 3.3 μg L -1 . The recoveries at the spiked level of 20 μg L -1 BTEX and styrene ranged from 97% - 103% with the relative standard deviations were (RSD, n=3) 1.0% - 7.6%.","PeriodicalId":11598,"journal":{"name":"Ekoloji","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Optimization of Static Head-Space Gas Chromatography - Mass Spectrometry-Conditions for the Determination of Benzene, Toluene, Ethyl benzene, Xylene, and Styrene in Model Solutions\",\"authors\":\"Ozlem Yilmazcan, E. Özer, B. Izgi, Ş. Gucer\",\"doi\":\"10.5053/EKOLOJI.2013.899\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method was developed and validated for the analysis of benzene, toluene, ethylbenzene, xylene (BTEX), and styrene in sea water samples using gas chromatography-mass spectrometry (GC-MS) with static headspace extraction. To carefully characterize the performance of this method, several factors affecting the parameters were studied in detail, such as the heating procedure, loop filling time, equilibrium temperature, the sample dilution ratio, equilibrium, and injection times. The optimized conditions are as follows: 1)the heating procedure, 50°C for 4 min, then increased to 170°C at 15°C min-1, 2) equilibrium temperature, 60°C, 3) equilibrium time, 5 min, and 4) injection time 0.5 min. Under the optimized conditions, the linear equations were obtained in the concentration range of 10 - 50 μg L-1 with good correlation coefficient values. The limits of detection were 1.8 - 3.3 μg L -1 . The recoveries at the spiked level of 20 μg L -1 BTEX and styrene ranged from 97% - 103% with the relative standard deviations were (RSD, n=3) 1.0% - 7.6%.\",\"PeriodicalId\":11598,\"journal\":{\"name\":\"Ekoloji\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ekoloji\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5053/EKOLOJI.2013.899\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ekoloji","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5053/EKOLOJI.2013.899","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Environmental Science","Score":null,"Total":0}
Optimization of Static Head-Space Gas Chromatography - Mass Spectrometry-Conditions for the Determination of Benzene, Toluene, Ethyl benzene, Xylene, and Styrene in Model Solutions
A method was developed and validated for the analysis of benzene, toluene, ethylbenzene, xylene (BTEX), and styrene in sea water samples using gas chromatography-mass spectrometry (GC-MS) with static headspace extraction. To carefully characterize the performance of this method, several factors affecting the parameters were studied in detail, such as the heating procedure, loop filling time, equilibrium temperature, the sample dilution ratio, equilibrium, and injection times. The optimized conditions are as follows: 1)the heating procedure, 50°C for 4 min, then increased to 170°C at 15°C min-1, 2) equilibrium temperature, 60°C, 3) equilibrium time, 5 min, and 4) injection time 0.5 min. Under the optimized conditions, the linear equations were obtained in the concentration range of 10 - 50 μg L-1 with good correlation coefficient values. The limits of detection were 1.8 - 3.3 μg L -1 . The recoveries at the spiked level of 20 μg L -1 BTEX and styrene ranged from 97% - 103% with the relative standard deviations were (RSD, n=3) 1.0% - 7.6%.
期刊介绍:
Cessation. Ekoloji is an international journal that focuses on papers that report results from original research on all disciplines engaged in the field of environmental research. We welcome articles that cover the entire spectrum of environmental problems and environmental pollutants, whether chemical, biological or physical. Its coverage extends to all environmentally related issues: air and water pollution, solid waste, noise, recycling, natural resources, ecology and environmental protection. It includes articles on basic and applied environmental pollution research, including environmental engineering and environmental health. All types of pollution are covered, including atmospheric pollutants, detergents, fertilizers, industrial effluents, metals, mining wastes, oil, pesticides, plastics, radioactive materials and sewage. It also includes research papers on ecological and environmental issues such as climate change, biodiversity. The primary criteria for publication are scientific quality and ecological/environmental significance.
The journal will be read and contributed to by biologists, applied ecologists, environmental scientists, natural resource specialists, environmental engineers, environmental health specialists, agro-ecologists, veterinaries, agricultural engineers, landscape planners and designers. The journal welcomes full "research papers" and short "research notes", only in the English language.