Ti-6Al-4V包覆壳聚糖/环氧树脂RS100双层膜的特性及腐蚀行为研究

IF 0.5 4区 工程技术 Q4 CHEMISTRY, APPLIED Indian Journal of Chemical Technology Pub Date : 2023-01-01 DOI:10.56042/ijct.v30i4.69328
K. Shreevani, B. Narayana, B. Sarojini, A. Ganesha, B. Praveen, B. Devendra, Sushmitha
{"title":"Ti-6Al-4V包覆壳聚糖/环氧树脂RS100双层膜的特性及腐蚀行为研究","authors":"K. Shreevani, B. Narayana, B. Sarojini, A. Ganesha, B. Praveen, B. Devendra, Sushmitha","doi":"10.56042/ijct.v30i4.69328","DOIUrl":null,"url":null,"abstract":"In the present study, implant material Ti-6Al-4V has been coated with eudragit (EU) and chitosan (CH) polymers to enhance surface properties. The deposition of polymer coating has covered the surface cracks to a significant level and the fact has been confirmed by FE-SEM coupled with EDAX wherein the atomic percentage of Ti (99.90%) in non-coated surface has been decreased markedly to 0.42% after coating. Scratch resistance and adhesion power of bilayer coating has been increased as indicated by the higher critical loads Lc 1 (16.71 N), Lc 2 (17.56 N), Lc 3 (17.96 N) when a progressive load of 1 N to 20 N is applied over the coated surface. Further, Electrochemical impedance spectroscopy (EIS) and potentiodynamic-polarization studies have shown that the value of polarization resistance is inversely proportional to the corrosion rate. Thus decrease in the corrosion rate from 107.5×10 -2 (mm year -1 ) for the non-coated alloy to 2.88×10 -2 (mm year -1 ) for CH/EU coating demonstrated that coating enhanced the corrosion resistance of the alloy in the physiological condition. The in vitro antibacterial test conducted against S. aureus, B. subtilis, P. vulgaris and P. auregenosa has shown a significant inhibition zone of 9 mm, 6 mm, 7 mm and 10 mm, respectively, thus indicating the possible application of the polymeric coating material on the dental implants.","PeriodicalId":13388,"journal":{"name":"Indian Journal of Chemical Technology","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Studies on characteristics and corrosion behaviour of chitosan/eudragit RS100 bilayer film coated Ti-6Al-4V\",\"authors\":\"K. Shreevani, B. Narayana, B. Sarojini, A. Ganesha, B. Praveen, B. Devendra, Sushmitha\",\"doi\":\"10.56042/ijct.v30i4.69328\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the present study, implant material Ti-6Al-4V has been coated with eudragit (EU) and chitosan (CH) polymers to enhance surface properties. The deposition of polymer coating has covered the surface cracks to a significant level and the fact has been confirmed by FE-SEM coupled with EDAX wherein the atomic percentage of Ti (99.90%) in non-coated surface has been decreased markedly to 0.42% after coating. Scratch resistance and adhesion power of bilayer coating has been increased as indicated by the higher critical loads Lc 1 (16.71 N), Lc 2 (17.56 N), Lc 3 (17.96 N) when a progressive load of 1 N to 20 N is applied over the coated surface. Further, Electrochemical impedance spectroscopy (EIS) and potentiodynamic-polarization studies have shown that the value of polarization resistance is inversely proportional to the corrosion rate. Thus decrease in the corrosion rate from 107.5×10 -2 (mm year -1 ) for the non-coated alloy to 2.88×10 -2 (mm year -1 ) for CH/EU coating demonstrated that coating enhanced the corrosion resistance of the alloy in the physiological condition. The in vitro antibacterial test conducted against S. aureus, B. subtilis, P. vulgaris and P. auregenosa has shown a significant inhibition zone of 9 mm, 6 mm, 7 mm and 10 mm, respectively, thus indicating the possible application of the polymeric coating material on the dental implants.\",\"PeriodicalId\":13388,\"journal\":{\"name\":\"Indian Journal of Chemical Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Chemical Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.56042/ijct.v30i4.69328\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Chemical Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.56042/ijct.v30i4.69328","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, APPLIED","Score":null,"Total":0}
引用次数: 1

摘要

在本研究中,植入材料Ti-6Al-4V被涂覆了eucragit (EU)和壳聚糖(CH)聚合物,以提高其表面性能。聚合物涂层的沉积使表面裂纹得到了很大程度的覆盖,FE-SEM结合EDAX证实了这一事实,涂层后未涂层表面的Ti原子率(99.90%)明显降低到0.42%。当在涂层表面施加1 ~ 20 N的累加载荷时,涂层的临界载荷Lc 1 (16.71 N)、Lc 2 (17.56 N)、Lc 3 (17.96 N)较高,表明涂层的抗划伤性和附着力有所提高。此外,电化学阻抗谱(EIS)和电位动力学极化研究表明,极化电阻的值与腐蚀速率成反比。腐蚀速率从未涂覆合金的107.5×10 -2 (mm -1)降低到CH/EU涂层的2.88×10 -2 (mm -1),说明在生理条件下,涂层增强了合金的耐蚀性。对金黄色葡萄球菌、枯草芽孢杆菌、寻常假单胞菌和金黄色葡萄球菌的体外抑菌试验显示,其抑菌带分别为9 mm、6 mm、7 mm和10 mm,表明该高分子涂层材料在种植体上的应用前景广阔。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Studies on characteristics and corrosion behaviour of chitosan/eudragit RS100 bilayer film coated Ti-6Al-4V
In the present study, implant material Ti-6Al-4V has been coated with eudragit (EU) and chitosan (CH) polymers to enhance surface properties. The deposition of polymer coating has covered the surface cracks to a significant level and the fact has been confirmed by FE-SEM coupled with EDAX wherein the atomic percentage of Ti (99.90%) in non-coated surface has been decreased markedly to 0.42% after coating. Scratch resistance and adhesion power of bilayer coating has been increased as indicated by the higher critical loads Lc 1 (16.71 N), Lc 2 (17.56 N), Lc 3 (17.96 N) when a progressive load of 1 N to 20 N is applied over the coated surface. Further, Electrochemical impedance spectroscopy (EIS) and potentiodynamic-polarization studies have shown that the value of polarization resistance is inversely proportional to the corrosion rate. Thus decrease in the corrosion rate from 107.5×10 -2 (mm year -1 ) for the non-coated alloy to 2.88×10 -2 (mm year -1 ) for CH/EU coating demonstrated that coating enhanced the corrosion resistance of the alloy in the physiological condition. The in vitro antibacterial test conducted against S. aureus, B. subtilis, P. vulgaris and P. auregenosa has shown a significant inhibition zone of 9 mm, 6 mm, 7 mm and 10 mm, respectively, thus indicating the possible application of the polymeric coating material on the dental implants.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Journal of Chemical Technology
Indian Journal of Chemical Technology 工程技术-工程:化工
CiteScore
0.90
自引率
20.00%
发文量
17
审稿时长
6-12 weeks
期刊介绍: Indian Journal of Chemical Technology has established itself as the leading journal in the exciting field of chemical engineering and technology. It is intended for rapid communication of knowledge and experience to engineers and scientists working in the area of research development or practical application of chemical technology. This bimonthly journal includes novel and original research findings as well as reviews in the areas related to – Chemical Engineering, Catalysis, Leather Processing, Polymerization, Membrane Separation, Pharmaceuticals and Drugs, Agrochemicals, Reaction Engineering, Biochemical Engineering, Petroleum Technology, Corrosion & Metallurgy and Applied Chemistry.
期刊最新文献
Green carbon dots from poppy seeds with conjugated hydrogel hybrid films for detection of Fe3+ Functionalization of fullerene with 4-benzo-9-crown-3 ether Methyl orange adsorption by modified montmorillonite nanomaterials: Characterization, kinetic, isotherms and thermodynamic studies Triazole-based C3-symmetric multivalent dendritic architecture as Cu(II) ion sensor Adsorption study on the removal of ciprofloxacin in aqueous solution by an acidic ion exchange resin with bifunctional group
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1