{"title":"输液中假丝酵母菌污染的快速检测","authors":"S. Oie, K. Kouda, H. Furukawa, A. Kamiya","doi":"10.5430/CNS.V6N4P80","DOIUrl":null,"url":null,"abstract":"We encountered a case of microbial contamination of infusion fluid detected based on the discoloration of an inline filter (membrane filter) in the main route. A cause of this contamination may be the use of an extension tube connected to the main route for more than a month. In the infusion fluid above the inline filter (on the high calorie end), 2.4 × 105 colony forming units (cfu)/ml of Candida parapsilosis was detected. “Adenosine triphosphate (ATP) + adenosine monophosphate (AMP)” was determined in addition. We conclude that microbial contamination of this infusion fluid can be rapidly estimated by measuring the amounts of “ATP + AMP”.","PeriodicalId":72616,"journal":{"name":"Clinical nursing studies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5430/CNS.V6N4P80","citationCount":"2","resultStr":"{\"title\":\"Rapid detection of Candida parapsilosis contamination in the infusion fluid\",\"authors\":\"S. Oie, K. Kouda, H. Furukawa, A. Kamiya\",\"doi\":\"10.5430/CNS.V6N4P80\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We encountered a case of microbial contamination of infusion fluid detected based on the discoloration of an inline filter (membrane filter) in the main route. A cause of this contamination may be the use of an extension tube connected to the main route for more than a month. In the infusion fluid above the inline filter (on the high calorie end), 2.4 × 105 colony forming units (cfu)/ml of Candida parapsilosis was detected. “Adenosine triphosphate (ATP) + adenosine monophosphate (AMP)” was determined in addition. We conclude that microbial contamination of this infusion fluid can be rapidly estimated by measuring the amounts of “ATP + AMP”.\",\"PeriodicalId\":72616,\"journal\":{\"name\":\"Clinical nursing studies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.5430/CNS.V6N4P80\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical nursing studies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5430/CNS.V6N4P80\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical nursing studies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5430/CNS.V6N4P80","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Rapid detection of Candida parapsilosis contamination in the infusion fluid
We encountered a case of microbial contamination of infusion fluid detected based on the discoloration of an inline filter (membrane filter) in the main route. A cause of this contamination may be the use of an extension tube connected to the main route for more than a month. In the infusion fluid above the inline filter (on the high calorie end), 2.4 × 105 colony forming units (cfu)/ml of Candida parapsilosis was detected. “Adenosine triphosphate (ATP) + adenosine monophosphate (AMP)” was determined in addition. We conclude that microbial contamination of this infusion fluid can be rapidly estimated by measuring the amounts of “ATP + AMP”.