四种商业免疫磁分离试剂盒检测隐孢子虫的比较。

IF 2.5 4区 环境科学与生态学 Q3 ENVIRONMENTAL SCIENCES Journal of water and health Pub Date : 2023-10-01 DOI:10.2166/wh.2023.217
Jeanne Claudeen Arona, Timothy J Hall, Flyn Mckinnirey, Fei Deng
{"title":"四种商业免疫磁分离试剂盒检测隐孢子虫的比较。","authors":"Jeanne Claudeen Arona,&nbsp;Timothy J Hall,&nbsp;Flyn Mckinnirey,&nbsp;Fei Deng","doi":"10.2166/wh.2023.217","DOIUrl":null,"url":null,"abstract":"<p><p>Cryptosporidium spp. are protozoan parasites of significant health importance found in environmental waters globally. Four commercially available Cryptosporidium-specific immunomagnetic separation (IMS) kits used in various water sample matrices were analysed and compared. Beads were characterised by flow cytometry and tested for the recovery efficiencies for oocysts spiked into different matrices: river water sediment, clay sample, and filter backwash sample. Results showed that Dynabeads™ Cryptosporidium and Waterborne Crypto-Grab™ kits contained immunoglobulin IgM antibody-coated beads. In contrast, the BioPoint CryptoBead and the TCS Isolate kits contained immunoglobulin IgG antibody-coated beads. BioPoint CryptoBead was significantly coated with more antibodies and were able to capture oocysts more rapidly compared to the other beads. Recovery efficiencies of Dynabeads™, TCS Isolate® beads, and BioPoint CryptoBead ranged from 55 to 93% when tested against different sample matrices, with BioPoint CryptoBead resulting in the highest at 93% in reagent-grade water and Dynabeads™ at 55%, the lowest against clay samples. The Waterborne beads did not perform well on any samples, with recovery efficiencies ranging from 0 to 8%. Fluorescence microscopy analyses showed that both the IMS method and the sample matrix processed affect the quality of the membranes, with the cleanest samples for microscopy examination observed from BioPoint CryptoBead.</p>","PeriodicalId":17436,"journal":{"name":"Journal of water and health","volume":"21 10","pages":"1580-1590"},"PeriodicalIF":2.5000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/wh_2023_217/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of four commercial immunomagnetic separation kits for the detection of Cryptosporidium.\",\"authors\":\"Jeanne Claudeen Arona,&nbsp;Timothy J Hall,&nbsp;Flyn Mckinnirey,&nbsp;Fei Deng\",\"doi\":\"10.2166/wh.2023.217\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Cryptosporidium spp. are protozoan parasites of significant health importance found in environmental waters globally. Four commercially available Cryptosporidium-specific immunomagnetic separation (IMS) kits used in various water sample matrices were analysed and compared. Beads were characterised by flow cytometry and tested for the recovery efficiencies for oocysts spiked into different matrices: river water sediment, clay sample, and filter backwash sample. Results showed that Dynabeads™ Cryptosporidium and Waterborne Crypto-Grab™ kits contained immunoglobulin IgM antibody-coated beads. In contrast, the BioPoint CryptoBead and the TCS Isolate kits contained immunoglobulin IgG antibody-coated beads. BioPoint CryptoBead was significantly coated with more antibodies and were able to capture oocysts more rapidly compared to the other beads. Recovery efficiencies of Dynabeads™, TCS Isolate® beads, and BioPoint CryptoBead ranged from 55 to 93% when tested against different sample matrices, with BioPoint CryptoBead resulting in the highest at 93% in reagent-grade water and Dynabeads™ at 55%, the lowest against clay samples. The Waterborne beads did not perform well on any samples, with recovery efficiencies ranging from 0 to 8%. Fluorescence microscopy analyses showed that both the IMS method and the sample matrix processed affect the quality of the membranes, with the cleanest samples for microscopy examination observed from BioPoint CryptoBead.</p>\",\"PeriodicalId\":17436,\"journal\":{\"name\":\"Journal of water and health\",\"volume\":\"21 10\",\"pages\":\"1580-1590\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/wh_2023_217/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of water and health\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.2166/wh.2023.217\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of water and health","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.2166/wh.2023.217","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

隐孢子虫是在全球环境水域发现的对健康具有重要意义的原生动物寄生虫。分析和比较了用于各种水样基质的四种市售隐孢子虫特异性免疫磁分离(IMS)试剂盒。通过流式细胞术对珠粒进行表征,并测试掺入不同基质(河水沉积物、粘土样品和过滤器反冲洗样品)的卵囊的回收效率。结果显示Dynabeads™ 隐孢子虫与水性隐抓斗™ 试剂盒含有免疫球蛋白IgM抗体包被的珠子。相比之下,BioPoint CryptoBead和TCS隔离试剂盒含有免疫球蛋白IgG抗体包被的珠。BioPoint CryptoBead明显被更多的抗体包裹,与其他珠子相比,能够更快地捕获卵囊。Dynabeads的回收效率™, 当针对不同的样品基质进行测试时,TCS Isolate®珠粒和BioPoint CryptoBead的含量在55%至93%之间,其中BioPoint CryptiBead在试剂级水中和Dynabeads中的含量最高,为93%™ 55%,与粘土样品相比最低。水性珠在任何样品上都表现不佳,回收率在0-8%之间。荧光显微镜分析表明,IMS方法和处理的样品基质都会影响膜的质量,BioPoint CryptoBead观察到最干净的显微镜检查样品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of four commercial immunomagnetic separation kits for the detection of Cryptosporidium.

Cryptosporidium spp. are protozoan parasites of significant health importance found in environmental waters globally. Four commercially available Cryptosporidium-specific immunomagnetic separation (IMS) kits used in various water sample matrices were analysed and compared. Beads were characterised by flow cytometry and tested for the recovery efficiencies for oocysts spiked into different matrices: river water sediment, clay sample, and filter backwash sample. Results showed that Dynabeads™ Cryptosporidium and Waterborne Crypto-Grab™ kits contained immunoglobulin IgM antibody-coated beads. In contrast, the BioPoint CryptoBead and the TCS Isolate kits contained immunoglobulin IgG antibody-coated beads. BioPoint CryptoBead was significantly coated with more antibodies and were able to capture oocysts more rapidly compared to the other beads. Recovery efficiencies of Dynabeads™, TCS Isolate® beads, and BioPoint CryptoBead ranged from 55 to 93% when tested against different sample matrices, with BioPoint CryptoBead resulting in the highest at 93% in reagent-grade water and Dynabeads™ at 55%, the lowest against clay samples. The Waterborne beads did not perform well on any samples, with recovery efficiencies ranging from 0 to 8%. Fluorescence microscopy analyses showed that both the IMS method and the sample matrix processed affect the quality of the membranes, with the cleanest samples for microscopy examination observed from BioPoint CryptoBead.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of water and health
Journal of water and health 环境科学-环境科学
CiteScore
3.60
自引率
8.70%
发文量
110
审稿时长
18-36 weeks
期刊介绍: Journal of Water and Health is a peer-reviewed journal devoted to the dissemination of information on the health implications and control of waterborne microorganisms and chemical substances in the broadest sense for developing and developed countries worldwide. This is to include microbial toxins, chemical quality and the aesthetic qualities of water.
期刊最新文献
Antibiotic resistance of E. coli isolates from different water sources in Mbarara, Uganda. Antimicrobial resistance characterization of Enterococcus faecium, Enterococcus faecalis and Enterococcus hirae isolated from marine coastal recreational waters in the State of São Paulo, Brazil. Application of miniaturized most probable number method for bacterial detection in water samples: detection of multi-drug-resistant Ralstonia insidiosa in drinking water. Determinants of adoption of household water treatment in Haiti using two analysis methods: logistic regression and machine learning. Environmental factors associated with Oncomelania hupensis lindoensis snails in a schistosomiasis-endemic area in Napu, Central Sulawesi.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1